Geri Dön

Yoğun bakımda takip edilen hastalarda optik sinir kılıf çapının ölçümü ile klinik ve radyolojik bulguların ilişkisi

The relationship of optic nerve sheath diameter and clinical and radiological findings in patients followed in intensi̇ve care uni̇t

  1. Tez No: 703460
  2. Yazar: MERVE İKBAL GÖNCÜ
  3. Danışmanlar: DOÇ. DR. AYÇA SULTAN ŞAHİN
  4. Tez Türü: Tıpta Uzmanlık
  5. Konular: Anestezi ve Reanimasyon, Anesthesiology and Reanimation
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2021
  8. Dil: Türkçe
  9. Üniversite: Sağlık Bilimleri Üniversitesi
  10. Enstitü: İstanbul Kanuni Sultan Süleyman Eğitim ve Araştırma Hastanesi
  11. Ana Bilim Dalı: Anesteziyoloji ve Reanimasyon Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 82

Özet

Amaç. Bu çalışmada Sağlık Bilimleri Üniversitesi Kanuni Sultan Süleyman Eğitim ve Araştırma Hastanesi Anesteziyoloji ve Reanimasyon Kliniği 3. basamak yoğun bakım ünitesine (YBÜ) farklı nedenler ile yatırılan hastaların demografik özellikleri, klinik bulguları ve radyolojik bulguları ile optik sinir kılıf çapı (OSKÇ) arasındaki ilişki araştırılmıştır. Gereç ve Yöntem. Prospektif izlem tasarımında yapılan bu tez çalışması, 1 Ocak 2021-30 Nisan 2021 tarihleri arasında 4 ay süreyle YBÜ'nde takip edilen 78 hastanın verileri analize dâhil edilmiştir. Hastaların demografik özellikleri (yaş, cinsiyet), beden kitle indeksi (kg/m2) (BKİ), intrakranyal patoloji, yoğun bakım yatış endikasyonu, komorbid hastalık, vital parametreler, Glasgow Koma Skalası (GKS), radyolojik olarak intrakranyal basınç artışı bulgusu, entübasyon varlığı, ventilasyon modu, ventilasyon parametreleri ve ultrasonografi ile ölçülen OSKÇ analiz edilmiştir. Verilerin toplanması için, Hastane Bilgi Yönetim Sistemi, hasta başı ventilasyon parametrelerinin gözlemi, laboratuvar sonuçları ve hasta dosyaları kullanılmıştır. ,Bulgular. Hastaların yaş ortalaması 58,7±18,6 ve %61,5'i erkektir. Hastaların yarısından fazlasında yatış nedenini nörolojik veya solunum ile ilgili patolojiler oluşturmaktadır. Hastaların %77,8'inde en az bir komorbid hastalık mevcuttur ve kalp-damar hastalıkları (%41,0) en sık saptanan komorbid hastalık olarak saptanmıştır. Hastaların %39,7'sinin GKS'si 8'in altında ve tüm yatan hastaların %42,3'ü ilk 24 saat içerisinde entübe edilerek takip ve tedavisi uygulanan hastalardır. Hastaların 24. ve 72 saatte OSKÇ ortalaması sırası ile 3,83±0,41 mm ve 3,84±0,40 mm olarak bulunmuştur. GKS puanına göre ağır nörolojik hasara sahip olan hastaların 24 ve 72. saat OSKÇ ortalamasının orta ve hafif nörolojik hasara sahip hasta OSKÇ ortalamalarından istatistiksel anlamlı olarak daha yüksek olduğu gözlenmiştir. Ayrıca yapılan ileri analiz ile hastaların hem 24. saat hem de 72. saatte GSK puanları ile OSKÇ ölçümleri arasında negatif yönlü istatistiksel olarak anlamlı korelasyon saptanmıştır. 24. ve 72 saatte radyolojik olarak intrakranyal basınç artışı bulgusu olan hastalarda istatistiksel olarak anlamlı şekilde OSKÇ ölçümünün, basınç artışı bulgusu olmayan hastalardan daha yüksek olduğu gözlenmiştir. İntrakranyal basınç artışını öngörmede 24. ve 72. saat OSKÇ değerleri kesim noktaları sırası ile >3,80 mm ve >4,00 mm olarak bulunmuştur. İleri analizler sonucunda; 24. saat OSKÇ 3,8 mm kesim noktası kabul edildiğinde, radyolojik olarak intrakranyal basınç artışını öngörmede bu değerin %100,0 sensitivite ve %66,7 spesifisite özellikleri gösterdiği bulunmuştur. Ayrıca 72. saat OSKÇ 4,0 mm kesim noktası kabul edildiğinde, radyolojik olarak intrakranyal basınç artışını öngörmede bu değerin %100,0 sensitivite ve % 77,5 spesifisite özellikleri gösterdiği saptanmıştır. Sonuç. OSKÇ ölçümü intrakranyal basınç artışı açısından yüksek riskli hastalarda tanı konulmasına yardımcı olarak, invazif veya medikal tedavilerin uygulanmasına fırsat sunmaktadır. Düşük riskli hastalarda ise basınç artışının olmadığının gösterilmesini sağlayarak tomografi ve MRG gibi görüntülüme testlerinin kullanımını azaltabilmektedir. Anahtar Kelimeler. Yoğun Bakım, Optik Sinir Kılıf Çapı, Ultrasonografi, Bilgisayarlı Tomografi, Manyetik Rezonans Görüntüleme

Özet (Çeviri)

Aim. In this study, we investigated the associations between the demographic characteristics, clinical findings, radiological findings and the sonographic optic nerve sheath diameter (ONSD) of the patients hospitalized in the Health Sciences University Kanuni Sultan Süleyman Training and Research Hospital, Anesthesiology and Reanimation Clinic, 3rd step intensive care unit (ICU) for different reasons. Material and Methods. In this thesis study, which was conducted in a prospective follow-up design, the data of 78 patients who were followed up in the ICU between January 1, 2021 and April 30, 2021 were included in the analysis. Demographics of patients (age, gender), body mass index (kg/m2) (BMI), intracranial pathology, indication for intensive care hospitalization, comorbid disease, vital parameters, Glasgow Coma Scale (GCS), radiological evidence of increased intracranial pressure, intubation presence, ventilation mode, ventilation parameters, and ONSD measured by ultrasonography were analyzed. Hospital Information Management System, observation of bedside ventilation parameters, laboratory results and patient files were used for data collection. Results. The mean age of the patients was 58.7±18.6 years and 61.5% were male. Neurological or respiratory pathologies constitute the reason for hospitalization in more than half of the patients. At least one comorbid disease was present in 77.8% of the patients, and cardiovascular diseases (41.0%) were found to be the most common comorbid disease. 39.7% of the patients had a GCS below 8 and 42.3% of all hospitalized patients were intubated within the first 24 hours. The mean ONSD of the patients at 24 and 72 hours was found to be 3.83±0.41 mm and 3.84±0.40 mm, respectively. According to the GCS score, the mean of the 24th and 72nd hour ONSD of the patients with severe neurological damage was statistically significantly higher than the mean of the patients with moderate and mild neurological damage. In addition, with the further analysis, a negative statistically significant correlation was found between the patients' GSK scores and ONSD measurements at both the 24th and 72nd hours. In patients with radiological signs of intracranial pressure increase at 24 and 72 hours, statistically significantly higher ONSD measurement was observed than in patients without signs of pressure increase. In predicting intracranial pressure increase, the 24th and 72nd hour ONSD values were found to be >3.80 mm and >4.00 mm at cutoff points, respectively. As a result of further analysis; When the 24th hour ONSD cutoff point was accepted as 3.8 mm, this value was found to have 100.0% sensitivity and 66.7% specificity in predicting the increase in intracranial pressure radiologically. In addition, when the cut-off point of the 72nd hour ONSD was accepted as 4.0 mm, this value showed 100.0% sensitivity and 77.5% specificity in predicting the increase in intracranial pressure radiologically. Conclusions. ONSD measurement provides an opportunity to apply invasive or medical treatments by helping to diagnose patients with high risk for increased intracranial pressure. In low-risk patients, it can reduce the use of imaging tests such as tomography and MRI by showing that there is no pressure increase. Keywords. Intensive Care, Optic Nerve Sheath Diameter, Ultrasonography, Computed Tomography, Magnetic Resonance Imaging

Benzer Tezler

  1. Yoğun bakımda takip edilen hastalarda optik sinir kılıf çap ölçümleri ile serum amonyak düzeyi ve sistemik hastalıklar arasındaki ilişki

    The relationship between optic nerve sheath diameter measurements, serum ammonia levels and systemic diseases in patients followed in intensive care unit

    ELİF GAMZE OĞUZ

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2023

    İç HastalıklarıSağlık Bilimleri Üniversitesi

    İç Hastalıkları Ana Bilim Dalı

    PROF. DR. GÜL GÜRSOY

    DR. ÖĞR. ÜYESİ UĞUR ÖZDEMİR

  2. Anevrizmatik subaraknoid kanama geçirmiş hastalarda coil embolizasyon uygulaması sonrasında vazospazm gelişen ve gelişmeyen olguların glaskow koma skoru, optik sinir kılıf çapı ve hemodinamik özelliklerinin değerlendirilmesi

    Evaluation of glasgow coma score, optic nerve sheath diameter and hemodynamic properties of patients who developed and did not develop vasospasm after coil embolization treatment in patients with aneurysmatic subarachnoid hemorrhage

    TUĞÇE KARAKOÇ

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2024

    Anestezi ve ReanimasyonKaradeniz Teknik Üniversitesi

    Anesteziyoloji ve Reanimasyon Ana Bilim Dalı

    PROF. DR. MÜGE KOŞUCU

  3. Yoğun bakımda intrakranial basınç artışı olan olgularda optik sinir kılıfı çapının ultrasonografi ile değerlendirilmesi

    Evaluation of optic nerve sheath diameter by ultrasonography in patients with intracranial pressure elevation in intensive care unit

    ASLI ARICAN ÇELİK

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2024

    Anestezi ve ReanimasyonSüleyman Demirel Üniversitesi

    Anesteziyoloji ve Reanimasyon Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ AHMET BİNDAL

  4. Yoğun bakımda yatak başı ultrason kullanımının tedavi planı ve prognoz üzerine etkisi

    The effect of bedside ultrasound use on treatment plan and prognosis in intensive care unit

    PELİN İŞCAN

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2024

    Anestezi ve ReanimasyonSağlık Bilimleri Üniversitesi

    Anesteziyoloji ve Reanimasyon Ana Bilim Dalı

    DOÇ. DR. DÖNDÜ GENÇ MORALAR

    DR. OĞUZ ÖZAKIN

  5. Yoğun bakımda takip edilen hastalarda yeni bir biyomarkır supar

    A new biomarker supar used in the management of patients in intensive care units

    SELÇUK NAZİK

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2015

    Klinik Bakteriyoloji ve Enfeksiyon HastalıklarıÇukurova Üniversitesi

    Enfeksiyon Hastalıkları ve Klinik Mikrobiyoloji Ana Bilim Dalı

    PROF. DR. HASAN SALİH ZEKİ AKSU