Transtibial protez kullanan bireylerde sağlam tarafta tabanlık kullanımının plantar basınç ve postüral stabiliteye anlık etkisi

Instant effect of the use of solid insoles on plantar pressure and postural stability in individuals using transtibial prosthesis

  1. Tez No: 706621
  2. Yazar: ONUR AKBEN
  3. Danışmanlar: DR. ÖĞR. ÜYESİ SEVAL KUTLUTÜRK
  4. Tez Türü: Yüksek Lisans
  5. Konular: Ortopedi ve Travmatoloji, Orthopedics and Traumatology
  6. Anahtar Kelimeler: Ayak, Plantar Basınç, Postüral Stabilite, Tabanlık, Transtibial Ampute, Ampütasyon, Duruş, Postural denge, Protezler ve implantlar, Tibia, Foot, İnsole, Plantar Pressure, Potural Stability, Transtibial Amputee, Amputation, Posture, Postural balance, Prostheses and implants, Sole, Tibia
  7. Yıl: 2021
  8. Dil: Türkçe
  9. Üniversite: İstanbul Medipol Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Ortez-Protez Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Tek taraflı alt ekstremite protezi kullanan bireylerde sağlam ekstremite üzerindeki aşırı yüklenme ve yürüyüş simetrisindeki bozulmalar önemli bir endişe kaynağıdır. Bu çalışmada transtibial protez kullanan bireylerin sağlam ekstremitesinde tabanlık kullanımının plantar pasınç ve postüral stabiliteye anlık etkisini incelemek amaçlandı. Çalışma transtibial protez kullanan 18-65 yaş aralığındaki 16 unilateral transtibial ampute üzerinde yapıldı. Ayak postürü Ayak Postür İndeksi, kalkaneus açısı CJ Ortho mobil uygulaması (Collège des Jeunes Orthopédistes – CJO) ve universal gonyometrik ölçüm, ayak plantar basıncı ve postüral stabilite Sensor Medica®️ sistemi ile değerlendirildi. Tabanlık öncesi ve sonrası yapılan değerlendirmeler anlık olarak kaydedildi. Araştırmanın istatistiksel analizi SPSS 21.00 kullanılarak, p<0,05 anlamlılık sınırında gerçekleştirildi. Bireylerin sağlam taraftaki tabanlıklı plantar basınç kuvvetleri ile (ön ayak yüklenme, toplam yüklenme, ön ayak temas yüzeyi, toplam temas yüzeyi, maksimum basınç) tabanlıksız sonuçları arasında istatistiksel olarak anlamlı fark bulundu (p<0,05). Tabanlıklı ve tabanlıksız ayak bileğinin subtalar eklem açısında istatistiksel olarak anlamlı fark tespit edildi (p<0,05). Transtibial protez kullanan amputelerde sağlam ektremitede tabanlığın postüral stabilite ve plantar basınç üzerine olumlu etkisinin olduğu belirlendi. Sağlam tarafta kişiye özel tabanlık kullanımının protez kullanan ampute bireyler için teşvik edilmesi gerektiğini düşünmekteyiz.

Özet (Çeviri)

Overloading on the contralateral limb and impaired gait symmetry in individuals using unilateral lower limb prosthesis are a major concern for amputees. The aim of this study was to investigate to effect of using insoles on the contralateral extremities of individuals using transtibial prosthesis on plantar pressure and postural stability. The study was performed on 16 unilateral transtibial amputees between the ages of 18-65, using transtibial prosthesis. Evaluation of foot posture (Foot Posture Index), measurement of calcaneus angle (CJ Ortho - Collège des Jeunes Orthopédistes - CJO) for postural stability and plantar pressure Sensor Medica®️ (Guidonia Montecelio, Rome, Italy) data before and after insoles recorded as. The statistical analysis of the study was performed using SPSS 21.00. at the significance limit of p <0.05. A statistically significant difference was found between the plantar pressure values with insoles on the contralateral side (forefoot loading, total loading, forefoot contact surface, total contact surface, maximum pressure values) of the individuals without insoles (p <0.05). A statistically significant difference was found in the subtalar joint angles of the ankle with and without insoles (p <0.05). In amputees using transtibial prosthesis, it was determined that the insoles in the contralateral extremity had a positive effect on postural stability and plantar pressure. We think that the use of custom insoles should be encouraged for amputees using prosthesis.

Benzer Tezler

  1. Alt ekstremite ampute hastalarda diz kıkırdak kalınlığının ultrasonografik değerlendirmesi ve klinik parametrelere etkisi

    Ultrasonographic evaluation of femoral cartilage thickness among lower extremity amputee i̇ndividiuals and effect on clinic parameters

    HABİP CAN KÜÇÜK

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2019

    Sağlık Bilimleri Üniversitesi

    Fiziksel Tıp ve Rehabilitasyon Ana Bilim Dalı

    Yükleniyor...

  2. Dinamik vakum sistemli protez kullanan unilateral transtibial amputelerin denge fonksiyonel mobilite ve protez memnuniyetinin incelenmesi

    Evaluation of the effect of the prosthetic dynamic vacuum suspension system on balance, functional mobility, and prosthetic satisfaction in unilateral transtibial amputee

    AYŞENUR ŞENGÖZ

    Yüksek Lisans

    Türkçe

    Türkçe

    2021

    İstanbul Medipol Üniversitesi

    Ortez-Protez Ana Bilim Dalı

    Yükleniyor...

  3. Transtibial amputasyonu olan bireylerde görsel geribildirimin fonksiyon, stabilite ve yaşam kalitesi üzerine etkilerinin incelenmesi

    Investigation of the effect of visual feedback on function, stability and quality of life in individuals with transtibial amputation

    ELİF KIRDI

    Yüksek Lisans

    Türkçe

    Türkçe

    2017

    Hacettepe Üniversitesi

    Fizik Tedavi ve Rehabilitasyon Ana Bilim Dalı

    Yükleniyor...

  4. Learning to walk on a human musculoskeletal system with powered prostheses

    Aktif protezli insan kas-iskelet sisteminde yürüme öğrenmesi

    İBRAHİM HAKKI DURMUŞ

    Yüksek Lisans

    İngilizce

    İngilizce

    2022

    İstanbul Teknik Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    Yükleniyor...

  5. Unilateral transtibial amputelerin protez kullanım deneyimi ve memnuniyeti

    Prosthetic user experience and satisfaction of unilateral transtibial amputees

    EMRE ÇAYIRLI

    Yüksek Lisans

    Türkçe

    Türkçe

    2021

    İstanbul Medipol Üniversitesi

    Ortez-Protez Ana Bilim Dalı

    Yükleniyor...