Geri Dön

A micro-computed tomographic evaluation of accuracy of different electronic apex locators

Farklı Apeks bulucuların doğruluğunun mikro bilgisayarlı tomografi kullanılarak değerlendirilmesi

  1. Tez No: 716250
  2. Yazar: AYLİN ERGELDİ
  3. Danışmanlar: PROF. DR. FATMA SEMRA SEVİMAY
  4. Tez Türü: Diş Hekimliği Uzmanlık
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Mikro-Bilgisayarlı Tomografi, Apex ID, Propex Pixi, Root ZX Mini, Elektronik Apeks Bulucu, Apikal Daralım, Çalışma Boyu Belirleme, Dental aygıtlar, Diş apeksi, Dişler, Tomografi-mikro bilgisayarlı, Micro-Computed Tomography, Apex ID, Propex Pixi, Root ZX Mini, Electronic Apex Locator, Apical Constriction, Working Length Determination, Dental instruments, Tooth apex, Teeth, Tomograph-micro computed
  7. Yıl: 2021
  8. Dil: Türkçe
  9. Üniversite: Ankara Üniversitesi
  10. Enstitü: Diş Hekimliği Fakültesi
  11. Ana Bilim Dalı: Endodonti Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Bu çalışmanın amacı; Apex ID (SybronEndo, Glendora, CA), Propex Pixi (Dentsply Maillefer, Ballaigues, Switzerland) ve Root ZX mini (J Morita, Tokyo, Japan) elektronik apeks bulucuların doğruluklarının gerçek çalışma uzunluğu ile karşılaştırılması ve mikro bilgisayarlı tomografi yöntemi kullanarak apikal daralım bölgesine olan yaklaşımlarının değerlendirilmesidir. Çalışmamızda 33 adet periodontal nedenle çekilmiş düz ve tek kanallı maksiller santral diş kullanıldı. Gerçek çalışma uzunluğu her bir diş için görsel olarak major foramenden 0,5 mm kısa olacak şekilde belirlendi. Elektronik apeks bulucular ile '0,0' noktasında ölçümler gerçekleştirilerek elektronik kök kanal çalışma uzunluğu belirlendi. Gerçek çalışma uzunluğu ile her bir elektronik apeks bulucular ile elde edilen ortalama uzunluk karşılaştırıldı. Elektronik çalışma uzunluğu belirledikten sonra eğeler dişe sabitlenerek mikro-BT (Bruker Microct Skyscan 1172, Kontich, Belgium) taraması yapıldı ve elektronik apeks bulucular ile yapılan ölçümlerin apikal daralıma yaklaşımları değerlendirildi. Bu işlemler her bir elektronik apeks bulucu için tekrarlandı. Elde edilen verilerin istatistiksel analizinde varyans ANOVA ve Bonferroni post hoc testleri kullanıldı. p<0,05 istatistiksel olarak anlamlı kabul edildi.Bu in vitro çalışma sonucunda; üç farklı elektronik apeks bulucu ile (Apex ID, Propex Pixi, Root ZX mini) elde edilen çalışma uzunluğu ve gerçek çalışma uzunluğu arasında anlamlı bir fark bulunmamıştır (p>0,05). Mikro-BT incelemesinde apikal daralıma ±0,5 mm ve ±1,0 yaklaşım yüzdeleri arasında istatistiksel olarak anlamlı bir fark tespit edilmemiştir (p>0,05).

Özet (Çeviri)

The aim of this study was to compare the accuracy of three electronic apex locators Apex ID (SybronEndo, Glendora, CA), Propex Pixi (Dentsply Maillefer, Ballaigues, Switzerland) and Root ZX mini (J Morita, Tokyo, Japan) to determined the working length and the evaluation of their approach to the apical constriction using microcomputer tomography method. In this study, 33 maxillary central teeth extracted for periodontal disease were used. The actual working length was visually determined to be 0,5 mm shorter than the major foramen for each tooth. Electronic root canal length was determined by performing measurements at the“0,0”point with electronic apex locators. The actual working length was compared with the average length obtained with each electronic apex locators. After determining the electronic working length, the files were fixed to the tooth and micro-CT scan (Bruker Microct Skyscan 1172, Kontich, Belgium) was performed and the apical narrowing approach of the measurements obtained with electronic apex locators was evaluated. This process were performed by all electronic apex locators. Data was analyzed variance ANOVA and Bonferroni post hoc tests were used. In all analyses, p<0,05 was taken to indicate statistical significance.Within the limitations of this study, no significant difference was found between the three electronic apex locators (Apex ID, Propex Pixi, Root ZX mini) and the actual working length (p> 0,05). According to micro-CT evaluation, there was no statistically significant difference between the ±0,5 mm and ±1,0 approach percentages to apical constriction (p> 0,05).

Benzer Tezler

  1. Molar dişlerde furkal perforasyonların radyografik olarak değerlendirilmesi: İn Vitro çalışma

    Radiographic evaluation of furcation perforations in molar teeth: An In Vitro study

    ZEHRA İREM ÖZTÜRK BARUT

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2025

    Diş HekimliğiAnkara Üniversitesi

    Ağız, Diş ve Çene Radyolojisi Ana Bilim Dalı

    PROF. DR. BENGİ ÖZTAŞ

    DR. ÖĞR. ÜYESİ ARDA BÜYÜKSUNGUR

  2. Eklemeli imalat ile farklı baskı açılarında üretilen daimi kronların marjinal ve internal uyumlarının mikro bilgisayarlı tomografi ile değerlendirilmesi

    Evaluation of marginal and internal fit of permanent crowns produced at different building angles using additive manufacturing and mikro-computed tomography

    DESTİNA SUAY SARI

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2025

    Diş HekimliğiBolu Abant İzzet Baysal Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ HATİCE SEVMEZ

  3. Çürük tanısının farklı yöntemlerle in vitro koşullarda değerlendirilmesi

    Evaluation of caries by using different diagnostic methods in vitro

    BUĞRA ŞENEL

    Doktora

    Türkçe

    Türkçe

    2009

    Diş HekimliğiGata

    Oral Diagnoz ve Radyoloji Ana Bilim Dalı

    DOÇ. DR. C. ÖZLEM ÜÇOK