Geri Dön

Evaluation of 3D printers accuracy in printing attachments of clear aligners

Üç boyutlu yazıcıların şeffaf plak ataşmanlarını baskı doğruluğunun değerlendirilmesi

  1. Tez No: 718472
  2. Yazar: AMMAR MOHAMMAD ISSA QAWASMI
  3. Danışmanlar: DOÇ. DR. RAHİME BURCU NUR YILMAZ
  4. Tez Türü: Yüksek Lisans
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: üç boyutlu yazıcı, şeffaf plaklar, şeffaf plak ataşmanları, üç boyutlu analiz, boyutsal baskı doğruluğu, Baskı kalitesi, Baskı teknikleri, Dental materyaller, Ortodonti, Ortodontik aygıtlar, Üç boyutlu malzemeler, Şeffaflık, three-dimensional printing, clear aligners, clear aligners' attachments, three-dimensional analysis, printing accuracy, Print quality, Printing techniques, Dental materials, Orthodontics, Orthodontic appliances, Three dimensional materials, Three dimensional printer, Transparency
  7. Yıl: 2022
  8. Dil: İngilizce
  9. Üniversite: Yeditepe Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Ortodonti Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Bu çalışmanın amacı Stereolitografi (SLA) ve Dijital Işık İşleme (DLP) üç boyutlu (3B) yazıcı teknikleri ile oluşturulan farklı ataşman şekillerinin üç boyutlu üstüste çakıştırma analizi ile hacimsel değişim ölçümlerinin değerlendirilmesi ve karşılaştırılmasıdır. Yeditepe Dişhekimliği Fakültesi Ortodonti Anabilim dalında tedavi gören hastaların ağıziçi dijital tarama arşivinden randomize olarak ikisi seçilmiş ve Ortho Analyzer 3D arayüz programı (3Shape A/S, Kopenhag, Danimarka). kullanılarak işlenmiştir. Rhinoceros 3B arayüz programı 7 versiyon (Robert McNeel & Associates, Seattle, ABD) ile altı farklı şekile sahip ataşman tasarlanmış ve dijital modele dönüştürülerek kontrol grubu oluşturulmuştur. Dijital modeler iki farklı yazıcı (SLA ve DLP) kullanılarak basılmıştır. Modeller TRIOS ağıziçi tarayıcı (3Shape A/S, Kopenhag, Danimarka) ile taranmış ve her yazıcı için 4 dijital model seti (üst ve alt olmak üzere, n=8) elde edilmiştir. Her dijital model seti ataşman şekline göre altı alt gruba (çalışma gruplarına) ayrılmıştır. Ortalama RMS ortalaması olarak hacimsel değişimlerin ölçülebilmesi için Geomagic Control X arayüz programı (3B Sistemler, Güney Karolina, ABD) kullanılarak incelenen ataşmanlar kontrol grubu üzerine üstüste çakıştırılmıştır. Yazıcı teknikleri arasında istatistiksel belirgin farklar tespit edilmiştir (p<0.05). SLA yazıcının RMS ortalama değerleri anlamlı düzeyde daha az olarak belirlenmiştir. Ataşman gruplarının karşılaştırılmasında da anlamlı farklar bulunmuştur (p<0.05). Elipsoid grubun RMS ortalamaları Yatay Dikdörtgen ve Optimal Rotasyon grubundan anlamlı düzeyde daha az olarak tespit edilmiştir. Şeffaf plaklarn üretiminde SLA yazıcılarının kullanımı önerilebilir. Boyutsal baskı doğruluğunu ataşman şekilleri etkilemektedir ancak ataşmanların oryantasyonu daha fazla önem arz etmektedir. Ataşmanların yazıcı platformuna göre son oryantasyonu ataşmanların konumlandırıldığı dişlerin inklinasyonuna, rotasyonuna ve devrilmesine, ataşmanın dişin uzun aksına olan mesafesine ve dişin ark içindeki konumuna bağlı olarak değişebileceği için öngörülebilir olamamaktadır.

Özet (Çeviri)

The aim of this study is to evaluate and compare the accuracy of different attachments' geometries printed by Stereolithography Apparatus (SLA) and Digital light processing (DLP) 3D printing techniques measuring volumetric changes using 3D superimposition analysis. Two Intraoral scans of patients treated at Yeditepe Dental Faculty and Hospital-Department of Orthodontics were selected randomly from the archive and were prepared using the Ortho Analyzer 3D software (3Shape A/S, Copenhagen, Denmark). Six attachments with different geometries were designed using Rhinoceros 3D Software version 7 (Robert McNeel & Associates, Seattle, USA), and were imported to the digital models to form the control group. The models were then printed using two different printers (SLA and DLP). Thereafter, the models were scanned with TRIOS intraoral scanner (3Shape, Copenhagen, Denmark) to result in two digital model sets (each upper and lower, total n=8) according to the printer's type. Each digital model set was divided into six subgroups (study groups) according to the shape of the attachments. The examined attachments were then superimposed to the control group using Geomagic Control X software (3D Systems, South Carolina, USA) to measure the volumetric changes by means of RMS mean. Statistically significant differences between printing techniques were present (p<0.05) with a significantly lesser RMS mean value for the SLA printer. Moreover, significant differences were shown between attachment groups (p<0.05) with the RMS mean of the Ellipsoid group being significantly lower than that of the Horizontal Rectangular and Optimized Rotation groups. SLA printers may be recommended for clear aligners' fabrication. The geometry of the attachments plays a role in the resultant printing accuracy. Along the same, the orientation of the attachments may be more influential. Nevertheless, the final orientation of the attachments in relationship to printing platform is unpredictable as it may be affected by the inclination, rotation and tipping of the teeth on that the attachments were placed, as well as the distance of the attachment to the long axis of the tooth along with the arch curvature.

Benzer Tezler

  1. Development of 3D food printer and use of mushrooms in 3D food printer within the scope of new plant-based food production

    3D gıda yazıcısı geliştirme ve mantarların bitkisel bazlı yeni ürün geliştirme çalışmaları kapsamında 3D yazıcıda kullanımı

    EVREN DEMİRCAN

    Doktora

    İngilizce

    İngilizce

    2023

    Gıda Mühendisliğiİstanbul Teknik Üniversitesi

    Gıda Mühendisliği Ana Bilim Dalı

    PROF. DR. BERAAT ÖZÇELİK

  2. Üç boyutlu yazıcı ile farklı dentalreçinelerden farklı kürleme süreleri ileüretilen inley restorasyonların doğruluğunundeğerlendirilmesi

    Evaluation of the accuracy of inlayrestorations produced with a 3D printer fromdifferent dental resins with different curi̇ngtimes

    YASEMİN ÖZDEN

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2024

    Diş HekimliğiAfyonkarahisar Sağlık Bilimleri Üniversitesi

    Restoratif Diş Tedavisi Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ LATİFE ALTINOK UYGUN

  3. Farklı yöntemler ile üretilmiş geçici restorasyonlarda: dijital olarak; uyum, doğruluk, kararlılık ve okluzal aşınmanın değerlendirilmesi: İn-vitro çalışma

    In temporary restorations made with different methods: digitally; evaluation of fit, accuracy, stability and occlusal wear: İN-vitro study

    SUAT GÜNGÖR

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2022

    Diş HekimliğiNecmettin Erbakan Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ MEHMET ESAD GÜVEN

  4. Plastik atık malzemelerin filament olarak geri dönüştürülmesi

    Recycling plastic waste materials as filament

    ÇİĞDEM TÜRKYILMAZ

    Yüksek Lisans

    Türkçe

    Türkçe

    2025

    Endüstri Ürünleri TasarımıErciyes Üniversitesi

    Endüstriyel Tasarım Mühendisliği Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ FATMA NAZLI ÖZSOLAK

    DR. ÖĞR. ÜYESİ ONUR ÖZSOLAK

  5. 3 boyutlu yazıcı ile üretilen indirekt braket taşıyıcıların braket konum doğruluklarının İn Vivo değerlendirilmesi

    Evaluation of bracket position accuracy of 3D printed indirect transfer trays In Vivo

    CEREN YILDIRIM

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2024

    Diş HekimliğiSağlık Bilimleri Üniversitesi

    Ortodonti Ana Bilim Dalı

    PROF. DR. SERKAN GÖRGÜLÜ