Geri Dön

Demir çelik sektörü için yerinde sodyum hipoklorit üretim sistemi ile soğutma kulelerinde kimyasal maliyetlerinin azaltılması ve dezenfeksiyon performans artışının sağlanması

Reducing chemical costs and increasing disinfection performance in cooling towers with on-site sodium hypochlorite production system for the iron and steel sector

  1. Tez No: 719910
  2. Yazar: ŞEYMA ULUKAYA
  3. Danışmanlar: DOÇ. DR. ERTUĞRUL ESMERAY
  4. Tez Türü: Yüksek Lisans
  5. Konular: Çevre Mühendisliği, Environmental Engineering
  6. Anahtar Kelimeler: Demir çelik sektörü, Dezenfeksiyon, Klorlama, Sodyum hipoklorit, Soğutma kuleleri, Iron steel sector, Disinfection, Chlorination, Sodium hypochlorite, Cooling towers
  7. Yıl: 2022
  8. Dil: Türkçe
  9. Üniversite: Karabük Üniversitesi
  10. Enstitü: Lisansüstü Eğitim Enstitüsü
  11. Ana Bilim Dalı: Çevre Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Su, içme suyu ve tarım için önemli olduğu kadar endüstri sistemlerinde de oldukça önemlidir. Endüstride su, kaynağından çekilmesi itibari ile atık su olana kadar bir çok prosesten geçerek bir noktadan diğer noktalara borular vasıtası ile iletilmektedir. Bu dolaşım esnasında bazı noktalardan su içerisine mikroorganizmalar karışabilir. Karışan bu mikroorganizmalar proses içerisinde bulunan bir çok makine teçhizat için çeşitli problemlere neden olabilmeleri nedeniyle dolaşımdaki suyun kalitesi mikrobiyolojik olarak belirli seviyelerde tutulması gerekmektedir. Bu kriterlerin sağlanabilmesi için endüstrilerde en yoğun olarak dezenfeksiyon yöntemi uygulanabilmektedir. Dezenfeksiyonda yöntem olarak en çok kimyasal metotlar tercih edilmektedir. Bu metotlardan, klorla dezenfeksiyon işlemi; gaz klor, sıvı klor ve yerinde elektroliz yöntemi ile sıvı klor üretimi şeklinde 3 farklı tipte yapılmaktadır. Son yıllarda bu metotlardan yönelimin yerinde elektroliz yöntemi ile sıvı klor üretimi kullanımı şeklinde olduğu görülmektedir. Çalışmamızda da Kardemir AŞ bünyesinde yer alan soğutma kulelerinden bir pilot bölge seçilerek dışarıdan temin edilen sodyum hipoklorit ve diğer kimyasalların kullanımı yerine; elektroliz sistemleri vasıtasıyla yerinde sodyum hipoklorit ve oksidan üretimi sağlayan üretim gerçekleştirilmesi amaçlanmıştır. Bu çalışma sonucunda kimyasal maliyetlerinin azaltılması, ana dezenfektan olarak kullanılan ticari sodyum hipoklorit tedariğinin ortadan kaldırılması, kule suyu dezenfeksiyon performanslarının arttırılması ve Kardemir'in ek dezenfektan ihtiyaçlarının karşılanması hedeflenmektedir. Çalışma sürecinde pilot bölge belirlenen Merkez Pompa-3 soğutma kulesi için demo kurulumu öncesi ve demo kurulumu anında 3 aylık bakiye klor ve mikrobiyolojik analiz verileri toplanmıştır. Bu verilerin ışığında 0,2 ppm kesintisiz bakiye klor sağlandığı görülmüştür. Ayrıca biyosit kullanımına ihtiyacın ortadan kalkabileceği ile ilgili veriler elde edilmiştir.

Özet (Çeviri)

Water is important for drinking water and agriculture, as well as for industrial systems. In industry, water is transmitted from one point to another via pipes, passing through many processes until it becomes waste water as it is drawn from its source. During this circulation, microorganisms can mix into the water at some points. Since these microorganisms can cause various problems for many machinery and equipment in the process, the quality of the circulating water must be kept at certain microbiological levels. In order to meet these criteria, the most intensive disinfection method can be applied in the industries. Chemical methods are the most preferred method in disinfection. Among these methods, disinfection with chlorine; It is made in 3 different types as gas chlorine, liquid chlorine and liquid chlorine production by on-site electrolysis method. In recent years, it is seen that the trend among these methods is the use of liquid chlorine production by on-site electrolysis method. In our study, instead of using sodium hypochlorite and other chemicals obtained from outside, by choosing a pilot region from the cooling towers within Kardemir AŞ; It is aimed to produce on-site sodium hypochlorite and oxidant production by means of electrolysis systems. As a result of this study, it is aimed to reduce the chemical costs, to eliminate the commercial sodium hypochlorite supply used as the main disinfectant, to increase the disinfection performance of the tower water and to meet the additional disinfectant needs of Kardemir. 3-month residual chlorine and microbiological analysis data were collected before and during the demo installation for the Central Pump-3 cooling tower, the pilot area of which was determined during the study process. In the light of these data, it has been observed that 0.2 ppm of uninterrupted residual chlorine is provided. In addition, data have been obtained that the need for the use of biocides may disappear.

Benzer Tezler

  1. Atherosklerotik kalp hastalıklarında risk faktörleri

    Risk factors in the coronary artery disease

    MURAT SUHER

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1987

    Gazi Üniversitesi

    İç Hastalıkları Ana Bilim Dalı

    Yükleniyor...

  2. Pasif güneş enerjisi sistemi ile bina ısıtılmasının ekonomik analizi

    Başlık çevirisi yok

    AHMET AKDENİZ

    Yüksek Lisans

    Türkçe

    Türkçe

    1987

    Ege Üniversitesi

    Enerji Ana Bilim Dalı

    Yükleniyor...

  3. Karıştırıcılar ve karıştırma kabındaki akım olaylarının incelenmesi

    Başlık çevirisi yok

    NADİR İLTEN

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    Uludağ Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    Yükleniyor...

  4. Kömürdeki piritin giderilmesi ve çözünürleştirme kinetiğinin incelenmesi

    Başlık çevirisi yok

    YAVUZ ONGANER

    Yüksek Lisans

    Türkçe

    Türkçe

    1987

    Atatürk Üniversitesi

    Yükleniyor...

  5. Küçük Yamanlar tepesi örneğinde kent yakın çevresinde rekreasyon alanı düzenleme projesi

    Başlık çevirisi yok

    NİHAN BULGUN

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    Ege Üniversitesi

    Peyzaj Mimarlığı Ana Bilim Dalı

    Yükleniyor...

  6. Pik demiri ve karbon çeliğinin sulu çözeltiler içindeki korozyon hızının tayini

    Determination of the rate of corrosion of the cast iran and carbon steel in the aqueous solutions

    EMİNE NAZAN ÜNAL

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    Gazi Üniversitesi

    Kimya Mühendisliği Ana Bilim Dalı

    Yükleniyor...