Deproteinizasyon ajanı hipokloröz asitin pit ve fissür örtücü iki farklı self adeziv akışkan kompozit ile kullanımının mineye bağlanma üzerine etkisi
The effect of the use of the deproteinization agent hypochlorous acid and two different pit and fissure sealant self-adhesive flowable composites upon its bonding with the enamel
- Tez No: 726850
- Danışmanlar: PROF. DR. ÇAĞDAŞ ÇINAR
- Tez Türü: Diş Hekimliği Uzmanlık
- Konular: Diş Hekimliği, Dentistry
- Anahtar Kelimeler: Dental bonding, Dental materyaller, Dental mine, Dental stres analizi, Fosforik asit, Hipokloröz asit, Sodyum hipoklorit, Çukur ve fissür örtücüler, Dental bonding, Dental materials, Dental enamel, Dental stress analysis, Phosphoric acid, Hypochlorous acid, Sodium hypochlorite, Pit and fissure sealants
- Yıl: 2022
- Dil: Türkçe
- Üniversite: Gazi Üniversitesi
- Enstitü: Diş Hekimliği Fakültesi
- Ana Bilim Dalı: Çocuk Diş Hekimliği Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
Bu çalışmanın amacı, deproteinizasyon ajanı hipokloröz asit ve sodyum hipokloritin, pit ve fissür örtücü iki farklı self adeziv akışkan kompozitin mineye bağlanma üzerine etkisini değerlendirmektir. Toplam 36 adet daimi çürüksüz ve restorasyonsuz 3. molar dişler çalışmaya dahil edilerek, rastgele altı gruba ayrıldı. Grup 1: %37'lik fosforik asit + Vertise™ Flow; Grup 2: 200 ppm Hipokloröz asit + %37'lik fosforik asit + Vertise™ Flow; Grup 3: %5,25'lik Sodyum hipoklorit + %37'lik fosforik asit + Vertise™ Flow; Grup 4: %37'lik fosforik asit + Constic; Grup 5: 200 ppm Hipokloröz asit + %37'lik fosforik asit + Constic; Grup 6: %5,25'lik Sodyum hipoklorit + %37'lik fosforik asit + Constic olarak oluşturuldu. Her grupta n=12 olacak şekilde dikdörtgen prizması şeklinde bloklar elde edildi. Deproteinizasyon ajanı uygulanan gruplar (Grup 2,3 ve 5,6) Grup 1 ve Grup 4'e göre istatistiksel olarak daha yüksek mikro gerilim bağlanma dayanımı değerleri gösterdi (P<0,05). Sadece asit uygulanan Vertise flow grubuna (Grup 1) göre sadece asit uygulanan Constic grubunun (Grup 4) mikro gerilim bağlanma dayanım değerlerinin daha yüksek olduğu görüldü (p=0,014). 200 ppm HOCl + asit uygulanan Vertise™ Flow grubu (Grup 2) ile 200 ppm HOCl + asit uygulanan Constic grubu (Grup 5) arasında mikro gerilim bağlanma dayanım değerleri arasında istatistiksel olarak fark bulundu (p=0,242). %5,25'lik NaOCl + asit uygulanan Vertise™ Flow grubu (Grup 3) ile %5,25'lik NaOCl + asit uygulanan Constic grubu (Grup 6) arasında da mikro gerilim bağlanma dayanım değerleri yönünden istatistiksel olarak anlamlı fark olmadığı bulundu (p=0,045). Sonuç olarak, deproteinizasyon ajanı uygulanan gruplar birbiri ile benzer, bunun yanında asit ve fissür örtücü uygulananlara göre istatistiksel olarak mikro gerilim bağlanma dayanım değerleri anlamlı şekilde daha yüksek bulundu.
Özet (Çeviri)
The aim of this study was to evaluate the effects of deproteinization agents hypochlorous acid and sodium hypochlorite on enamel bonding of two different self-adhesive flowable composites for pit and fissure sealants. A total of 36 permanent caries and non-restorative third molar teeth were included in the study and randomly divided into six groups. Group 1: 37% phosphoric acid + Vertise™ Flow; Group 2: 200 ppm Hypochlorous acid + 37% phosphoric acid + Vertise™ Flow; Group 3: 5.25% Sodium hypochlorite + 37% phosphoric acid + Vertise™ Flow; Group 4: 37% phosphoric acid + Constic; Group 5: 200 ppm Hypochlorous acid + 37% phosphoric acid + Constic; Group 6: It was formed as 5.25% sodium hypochlorite + 37% phosphoric acid + Constic. Bars in the form of rectangular prisms were obtained with n=12 in each group. Deproteinization agent applied groups (Groups 2, 3 and 5,6) showed statistically higher microtensile bond strength values compared to Group 1 and Group 4 (P<0.05). It was observed that the microtension bond strength values of the Constic group (Group 4), which was applied only acid, were higher than the Vertise™ Flow group (Group 1), which was applied only acid (p=0.014). A statistical difference was found between the microtension bond strength values between the Vertise™ Flow group (Group 2) applied 200 ppm HOCl + acid and the Constic group (Group 5) applied 200 ppm HOCl + acid (p=0.242). It was also found that there was no statistically significant difference between the Vertise™ Flow group (Group 3) applied with 5.25% NaOCl + acid and the Constic group (Group 6) applied with 5.25% NaOCl + acid in terms of microtension bond strength values (p=0.045). As a result, the groups treated with deproteinization agents were similar to each other, and the microtension bond strength values were found to be statistically higher than those treated with acid and fissure sealant.
Benzer Tezler
- Alt ekstremitede iskemi/ reperfüzyon sonrası oluşan serbest oksijen radikallerinin böbreğe etkisi ve oksijen süpürücülerinin rolü
The Effect of free oxygen radicals on kidney after ischemia and reperfusion of lower extremities and the role of oxygen radical scavengers
K. TEKİN İNCE
- Biyolojik örneklerde kolay uygulanabilir, enzimatik inozitol tayin yönteminin geliştirilmesi
Development of on available enymatic method for the measurement of inositol in biological samples
EMEL ÇAĞLAR
- Yüksek basınçlı sıvı kromatografisi (HPLC) ile plazma homosistein ölçüm yöntemlerinin karşılaştırılması
Başlık çevirisi yok
EMİN ÖZGÜR AKGÜL
- Maternal serum ve fetus kord serumu bakır, çinko ve leptin düzeyleri ve doğum ağırlığı ilişkisinin incelenmesi
Investigation of the association between maternal serum and cord serum copper, zinc and leptin levels and birth weight
ÜMİT ÖZDEMİR
- Production of hydroxylapatite from animal bone
Hayvan kemiğinden hidroksilapatit üretimi
ŞEYMA GÖREN
Doktora
İngilizce
2003
Boğaziçi ÜniversitesiBiyomedikal Bilimler ve Mühendislik Ana Bilim Dalı
Yükleniyor...