Geri Dön

Farklı kumlama ve femtosaniye lazer parametrelerinin yüksek translusent zirkonyanın eğilme dayanımına etkisi

The effect of different sandblasting and femtosecond laser parameters on the flexural strength of hi̇gh translucent zirconia

  1. Tez No: 741833
  2. Yazar: BANUÇİÇEK KANDEMİR
  3. Danışmanlar: PROF. DR. MÜNİR TOLGA YÜCEL
  4. Tez Türü: Diş Hekimliği Uzmanlık
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: CAD/CAM, Dental stres analizi, Mikroskopi-elektron taramalı, Protetik diş tedavisi, Zirkonyum, CAD/CAM, Dental stress analysis, Microscopy-electron scanning, Prosthetic dental treatment, Zirconium
  7. Yıl: 2022
  8. Dil: Türkçe
  9. Üniversite: Selçuk Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Bu çalışmanın amacı; sinterleme sonrası yüksek translusent zirkonya yüzeylerde uygulanan farklı parametrelerdeki kumlama ve femtosaniye lazerin eğilme dayanımı üzerindeki etkisini değerlendirmektir. Çalışmada, CAD/CAM sistemiyle üretilebilen yüksek translusent zirkonya (VITA YZ, Super Translucent Zirconia) disk bloklarından, CAM cihazı kullanılarak frezeleme işlemi ile 108 örnek hazırlanmıştır. Her grupta 12 örnek olacak şekilde 9 gruba ayrılmıştır. Yüzey işlemlerine göre; Gr1: kontrol, Gr2: 50 μm Al2O3 kumlama, Gr3: 110 μm Al2O3 kumlama, Gr4: femtosaniye lazer 400 mW atım, Gr5: femtosaniye lazer 800 mW atım, Gr6: femtosaniye lazer 400 mW atım ve 50 μm Al2O3 kumlama, Gr7: femtosaniye lazer 400 mW atım ve 110 μm Al2O3 kumlama, Gr8: femtosaniye lazer 800 mW atım ve 50 μm Al2O3 kumlama, Gr9: femtosaniye lazer 800 mW atım ve 110 μm Al2O3 kumlama olarak gruplar belirlenmiştir. Yüzey işlemleri tamamlanan örneklere 3 top üzeri eğilme testi yapılmıştır. ISO 6872 standartlarına göre kırılma olana kadar yük uygulanmıştır. Her gruptan birer örneğe SEM analizi uygulanmıştır. Elde edilen veriler istatistiksel açıdan Shapiro-Wilk testi, Kruskal Wallis testi ve Dunn testi ile incelenmiştir. SEM görüntüleri, kumlama ve lazer işlemlerinin önemli derecede yüzey değişikliğine yol açtığını göstermiştir. Eğilme dayanımı değerlerine bakıldığında lazer grupları kontrol grubuna göre daha düşük değerler göstermiştir (p<0,05). 50 μm kumlama grubunun eğilme dayanımını artırdığı görülmüştür (p>0,05). Lazer sonrası kumlama yapılan grupların eğilme dayanım değerlerini artırdığı görülmüştür (p>0,05).

Özet (Çeviri)

The aim of this study was to evaluate the effect of different sandblasting and femtosecond laser parameters on the flexural strength of high translucent zirconia surfaces after sintering. In the study, 108 specimens were prepared from high translucent zirconia (VITA YZ, Super Translucent Zirconia) disc blocks, which can be produced with the CAD/CAM system through milling using a CAM device. The specimens were divided into 9 groups including 12 specimens in each group. Groups were formed according to the surface treatments – Gr1: control; Gr2: 50 μm Al2O3 airborne particle abrasion; Gr3: 110 µm Al2O3 airborne particle abrasion; Gr4: 400 mW pulses femtosaniye laser; Gr5: 800 mW pulses femtosaniye laser; Gr6: 400 mW pulses femtosaniye laser and 50 µm Al2O3 airborne particle abrasion; Gr7: 400 mW pulses femtosaniye laser and 110 μm Al2O3 airborne particle abrasion; Gr8: 800 mW pulses femtosaniye laser and 50 µm Al2O3 airborne particle abrasion, and Gr9: 800 mW pulses femtosaniye laser and 110 µm Al2O3 airborne particle abrasion. Piston-on-three-balls method was applied on the specimens of which surface processes were completed. According to ISO 6872 standards, loads were applied to the specimens until fraction. Scanning electron microscope (SEM) analysis was performed on one specimen per group. The acquired data were statistically analysed via Shapiro-Wilk, Kruskal Wallis and Dunn tests. SEM images showed that airborne particle abrasion and laser treatments resulted in significant surface changes. When the biaxial flexural strength values were examined, the laser groups showed lower values than the control group (p<0.05). It was observed that the 50 μm Al2O3 airborne particle abrasion group increased biaxial flexural strength values (p>0,05). It was observed that the flexural strength values of the groups that were airborne particle abrasion after laser increased (p>0,05).

Benzer Tezler

  1. Bazı esterlerin kinetik incelenmesi ve termodinamik parametrelerin belirlenmesi

    Kinetic study and detesmination of thermodnamic parameters of some esters

    İBRAHİM TAŞ

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    Kimya MühendisliğiUludağ Üniversitesi

    Kimya Ana Bilim Dalı

    PROF. DR. MUSTAFA CEBE

  2. Testosteron dihidrotestosteron ve östrojenin benign prostat hiperplazisindeki etyolojik rolleri

    The roles of testosterone, dihydrotestosterone and estradiole on the etiology of benign prostatic hyperplasia

    HALUK TOKUÇOĞLU

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1986

    ÜrolojiGazi Üniversitesi

    Üroloji Ana Bilim Dalı

  3. Süt formüllerinin tüketim uygulamaları ve süt formüllerinin C vitamini içeriği ile pH değerleri

    Başlık çevirisi yok

    GÖNÜL VAROL

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    Besin Hijyeni ve Teknolojisiİstanbul Üniversitesi

    Çocuk Gelişimi Ana Bilim Dalı

    DOÇ. DR. TÜRKAN KUTLUAY