Endodontide kullanılan farklı biyomateryallerin radyoopasitelerinin karşılaştırılması
Comparison of radiopacity of various biomaterials used in endodontics
- Tez No: 743827
- Danışmanlar: DOÇ. DR. BERİVAN TUĞBA TÜRK SOMER
- Tez Türü: Doktora
- Konular: Diş Hekimliği, Dentistry
- Anahtar Kelimeler: Biodentin, Biyomedikal ve dental materyaller, Biyouyumlu materyaller, Endodonti, Kontrast maddeler, Mineral trioksit agregat, Radyografi, Radyografi-dental, Biodentine, Biomedical and dental materials, Biocompatible materials, Endodontics, Contrast media, Mineral trioxide aggregate, Radiography, Radiography-dental
- Yıl: 2022
- Dil: Türkçe
- Üniversite: Ege Üniversitesi
- Enstitü: Sağlık Bilimleri Enstitüsü
- Ana Bilim Dalı: Endodonti Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
Çalışmamızın amacı farklı firmalar tarafından üretilen endodontik biyoseramiklerin radyoopasitelerinin dijital radyografik görüntüler üzerinde karşılaştırılmasıdır. Çalışmamızda test materyalleri üretici firmaların önerileri doğrultusunda hazırlanarak 5 mm çapında 1 mm yüksekliğinde standart silindirik kalıpların içine yerleştirildi ve etüvde 48 saat inkübe edildi. Obje-ışın kaynağı mesafesi 30 cm olacak şekilde ayarlandı ve fosfor plaklar 60 kVp, 7 mA'da 0.32 sn süre ile ışınlandı. Plaklar daha sonra tarayıcı ile taranarak elde edilen görüntüler kaydedildi. Her test örneğinin, dentinin ve alüminyum step-wedge'in her basamağının ortalama gri değerleri (MGV) bir bilgisayar programının histogram özelliği kullanılarak değerlendirildi ve Excel yazılımı kullanılarak penetrometre üzerinden Al mm eşdeğerlerine dönüştürüldü. İstatistiksel analizler IBM SPSS Statistics 25,0 programı kullanılarak gerçekleştirildi. Biodentine materyalinin radyoopasite ortalama değeri diğer tüm test materyallerinden istatistiksel olarak anlamlı düzeyde düşük olarak görüldü (p<0,05). MM-MTA materyalinin radyoopasite ortalama değeri ile MTA Angelus ve Endoart MTA materyalleri arasında istatistiksel olarak anlamlı bir fark bulunamadı (p>0,05), diğer materyallerle ise arasında istatistiksel olarak anlamlı düzeyde farklı bulundu (p<0,05). Tehnodent Rootdent materyalinin radyoopasite ortalama değeri diğer tüm materyallerden istatistiksel olarak anlamlı düzeyde farklı görüldü (p<0,05). MTA BioRep materyalinin radyoopasite ortalama değeri diğer tüm materyallerden istatistiksel olarak anlamlı düzeyde farklı bulundu (p<0,05). MTA Angelus materyalinin radyoopasite ortalama değeri ile MM-MTA, ProRoot MTA, Bio MTA+ ve Endoart MTA materyalleri arasında istatistiksel olarak anlamlı fark görülmedi (p>0,05); Biodentine, Tehnodent Rootdent, MTA BioRep ve dentin gruplarıyla arasında ise istatistiksel olarak anlamlı düzeyde farklılık görüldü (p<0,05). ProRoot MTA materyalinin radyoopasite ortalama değeri ile MTA Angelus, Bio MTA+ ve Endoart MTA materyalleri arasında istatistiksel olarak anlamlı bir fark bulunamadı (p>0,05); Biodentine, MM-MTA, Tehnodent Rootdent, MTA BioRep ve dentin arasında ise istatistiksel olarak anlamlı bir fark bulundu (p<0,05). Bio MTA+ materyalinin radyoopasite ortalama değeri ile MTA Angelus ve ProRoot MTA materyalleri arasında istatistiksel olarak anlamlı bir fark bulunamadı (p>0,05); Biodentine, MM-MTA, Tehnodent Rootdent, MTA BioRep, Endoart MTA ve dentinden istatistiksel olarak anlamlı düzeyde farklı bulundu (p<0,05). Endoart MTA materyalinin radyoopasite ortalama değeri ile MM-MTA, MTA Angelus ve ProRoot MTA materyalleri arasında istatistiksel olarak anlamlı bir fark görülmedi (p>0,05); Biodentine, Tehnodent Rootdent, MTA BioRep, Bio MTA+ ve dentin gruplarıyla ise istatistiksel olarak anlamlı düzeyde farklı bulundu (p<0,05). Bütün materyallerin radyoopasite değerleri istatistiksel olarak anlamlı şekilde dentin dokusundan daha yüksekti (p<0,05). Çalışmaya dahil edilen tüm materyaller ISO standardına uygun bir radyoopasite sergilerken kendi içlerinde farklı radyoopasite değerleri göstermiştir. Materyaller arasında ProRoot MTA 8,09±0,58 mm Al ile en yüksek radyoopasite değerine sahipken, Biodentine 4,10±0,28 mm Al ile en düşük radyoopasite değerini gösterdi. Tüm materyaller dentin dokusundan daha yüksek radyoopasite gösterdi.
Özet (Çeviri)
The aim of our study is to compare the radiopacities of endodontic bioceramics produced by different companies on digital radiographic images. In our study, the test materials were prepared in accordance with the recommendations of the manufacturers, placed in standard cylindrical molds with a diameter of 5 mm and a height of 1 mm and incubated in an oven for 48 hours. The object-beam source distance was adjusted to be 30 cm and the phosphor plates were irradiated at 60 kVp, 7 mA for 0.32 seconds. The plates were then scanned with the scanner and the images obtained were recorded. The mean gray values (MGV) of each step of each test specimen, dentin, and aluminum step-wedge were evaluated using the histogram feature of a computer program and converted to Al mm equivalents via the penetrometer using Excel software. Statistical analyzes were performed using the IBM SPSS Statistics 25.0 program. The mean radiopacity value of the biodentine material was statistically significantly lower than all other test materials (p<0.05). No statistically significant difference was found between the mean radiopacity value of the MM-MTA material and MTA Angelus and Endoart MTA materials (p>0.05), it was found to be statistically different from other materials (p<0.05). The mean radiopacity value of the Tehnodent Rootdent material was statistically significantly different from all other materials (p<0.05). The mean radiopacity value of MTA BioRep material was found to be statistically significantly different from all other materials (p<0.05). There was no statistically significant difference between the mean radiopacity value of the MTA Angelus material and the MM-MTA, ProRoot MTA, Bio MTA+ and Endoart MTA materials (p>0.05); There was a statistically significant difference between Biodentine, Tehnodent Rootdent, MTA BioRep and dentin groups (p<0.05). There was no statistically significant difference between the mean radiopacity value of ProRoot MTA material and MTA Angelus, Bio MTA+ and Endoart MTA materials (p>0.05); A statistically significant difference was found between Biodentine, MM-MTA, Tehnodent Rootdent, MTA BioRep and dentin (p<0.05). There was no statistically significant difference between the mean radiopacity value of Bio MTA+ material and MTA Angelus and ProRoot MTA materials (p>0.05); Biodentine was statistically different from MM-MTA, Tehnodent Rootdent, MTA BioRep, Endoart MTA and dentin (p<0.05). There was no statistically significant difference between the mean radiopacity value of Endoart MTA material and MM-MTA, MTA Angelus and ProRoot MTA materials (p>0.05); There were statistically significant differences between Biodentine, Tehnodent Rootdent, MTA BioRep, Bio MTA+ and dentin groups (p<0.05). Radiopacity values of all materials were statistically significantly higher than dentin tissue (p<0.05). While all the materials included in the study exhibited a radiopacity in accordance with the ISO standard, they showed different radiopacity values within themselves. Among the materials, ProRoot MTA had the highest radiopacity value with 8.09±0.58 mm Al, while Biodentine showed the lowest radiopacity value with 4.10±0.28 mm Al. All materials showed higher radiopacity than dentin tissue.
Benzer Tezler
- Güncel kanal içi ilaçların ve yeni hidrojellerin rejeneratif endodontide kullanımı sonrasında E. faecalis biyofilmini uzaklaştırma etkinliği ve kök hücreler üzerindeki sitotoksik ve alkalen fosfataz aktivitesi
E. faecalis biofilm removal efficacy and cytotocix and alkaline phosphatase activity on stem cells after the use of conventional medicaments and new hydrogels in regenerative endodontics
ADEM ÖZTÜRK
Diş Hekimliği Uzmanlık
Türkçe
2024
Diş HekimliğiSelçuk ÜniversitesiEndodonti Ana Bilim Dalı
PROF. DR. AYÇE ÜNVERDİ ELDENİZ
- Furkasyon perforasyonlarının tamirinde kullanılan farklı biyomateryallerin sızdırmazlıklarının karşılaştırılması
Comparison of the sealing properties of different biomaterials used in the repair of furcation perforations
NURSELİ GÜNDOĞDU
Diş Hekimliği Uzmanlık
Türkçe
2024
Diş HekimliğiKocaeli ÜniversitesiEndodonti Ana Bilim Dalı
DR. ÖĞR. ÜYESİ SENA KAŞIKÇI
- Son yıllarda geliştirilen 4 farklı endodontik biyomateryalin simüle edilmiş immatür dişlerin kırılma direncine etkisinin kalsiyum hidroksit ile karşılaştırmalı olarak değerlendirilmesi
Comparative evaluation of recently developed four endodontic biomaterials with calcium hydroxide regarding their effect on the fracture resistance of immature simulated teeth
ASLI SOĞUKPINAR
Diş Hekimliği Uzmanlık
Türkçe
2017
Diş HekimliğiKırıkkale ÜniversitesiPedodonti Ana Bilim Dalı
YRD. DOÇ. DR. VOLKAN ARIKAN
- Rejeneratif endodontik tedavili dişlere uygulanan farklı materyallerin ısırma ve travma kuvvetleri altında stres dağılımı üzerine etkisi: Üç boyutlu sonlu elemanlar analizi
Effect of different materials applied to regenerative endodontically treated teeth on stress distribution under occlusal and traumatic forces: Three-dimensional finite element analysis
BUSE CANSU TOKER
Diş Hekimliği Uzmanlık
Türkçe
2025
Diş HekimliğiKütahya Sağlık Bilimleri ÜniversitesiEndodonti Ana Bilim Dalı
DR. ÖĞR. ÜYESİ ARZU KAYA MUMCU
- Farklı güncel biyomateryaller ile doldurulan yapay rezorptif defektlere sahip kök kanallarında; ph değişiklikleri, kalsiyum iyon salınımı ve kırılma direncinin incelenmesi
Evaluation of ph changes, calcium ion release and fracture resistance of teeth with artificial root resorptions and filled using different contemporary biomaterials
SEBAHAT ÖZLER