Geri Dön

Düşük yoğunluklu gaz yakmalı radyant ısıtma sisteminin pratik ve ekonomik açıdan incelenmesi ve standart ısıtma sistemleri ile karşılaştırılması

Başlık çevirisi mevcut değil.

  1. Tez No: 75398
  2. Yazar: CEM ÖZEN
  3. Danışmanlar: PROF. DR. MURAT TUNÇ
  4. Tez Türü: Yüksek Lisans
  5. Konular: Makine Mühendisliği, Mechanical Engineering
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 1998
  8. Dil: Türkçe
  9. Üniversite: İstanbul Teknik Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Makine Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Enerji Bilim Dalı
  13. Sayfa Sayısı: 91

Özet

Özet yok.

Özet (Çeviri)

SUMMARY PRACTICAL AND ECONOMICAL STUDY OF LOW - INTENSITY GAS FIRED RADIANT HEATING SYSTEMS AND A COMPARISON WITH CONVENTIONAL HEATING SYSTEMS Abstract Low intensity gas fired radiant tube heating systems are mostly used for heating large industrial buildings which cannot be achieved economically with conventional heating systems. Preceding studies show that low intensity gas fired infrared radiant tube heating equipment's energy savings are 30% to 50% or more. The principle of radiant energy is that it heats solid objects and the floor, not the air. In spaces which are heated with radiant heating systems, normal comfort levels are provided at a lower ambient temperature. In this study all radiant heating system alternatives have been introduced and some comparisons for advantages, disadvantages, costs, maintenance have been made for these systems. A calculation for a selected building with a low intensity gas fired radiant tube heating system has been made and the results have been shown in figures. Introduction Installation of radiant heating systems has begun in the United States in about 1 955. In Europe with becoming widespread of the use of natural gas, the use for these systems has begun twenty years ago. Gas fired radiant systems can also be used with L.P.G., but it is more logical to use natural gas for these systems, depending on the fuel costs. In 1 950's when these systems were installed, there was little information on the practical application of“infrared”radiation for comfort heating. Up to now many studies have been made to develop radiant heating systems. XIIIA wide range of radiant system applications shows that this kind of heating systems are necessary for the heating of large industrial buildings. Instead of total building heating it is also possible to heat a selected area with the spot heating alternative of radiant heating. Radiant systems, are systems that deliver more than half of their useful heat output by means of infrared radiation. In practise this means systems with emitter temperatures greater than 100 °C, such as gas radiant tubes and plaques, electric quartz linear heaters, steam radiant panels and others. In this work, the low intensity gas fired radiant tube heating equipment and its calculation has been studied in detail. To understand, how radiant heating system works, basic principles of heat transfer has been summarized. There are three modes of heat transfer: conduction, convection and radiation. Radiation is an electromagnetic process of which heat radiation is one form. Heat radiation is the emission from a source of electromagnetic waves having wavelengths in the infrared band between visible light and radio waves. Simply, heat radiation is further defined as an electromagnetic transfer between two surfaces. The heat generation occurred with striking of infrared rays onto a solid body which stimulates the molecules within that body with causing them to move rapidly. This process does not require an intermediate medium as in the case of convected heat. Convected heat uses air as the medium to transfer the heat energy. With radiant heat the objects, bodies and surfaces are heated directly. The air is not heated directly with the effect of radiant heat. It is heated with the effect of convection from the heated bodies and surfaces. Radiant appliances can be classified in several ways. In this study radiant appliances are classified according to the operation temperatures of their emitting surfaces. Simply, radiant appliances can be classified in two groups, according to their emitting surface temperatures. The first group of this radiant appliances can be defined as high and medium intensity radiant appliances which emitting surface temperatures are above 815 °C. High and medium intensity radiant appliances can be classified again in two groups. These two groups can be described as linear quartz radiant tubes and gas plaque radiant heating appliances which have both a high temperature emitting surface. These systems which take the form of open flame, unvented appliances with incandescent ceramic faces, are normally utilized in intermittent, localized or spot heating situations. XIVThe second group of this radiant appliances, can be defined as low intensity radiant appliances which emitting surface temperatures are between 260 °C and 815 °C. Gas fired radiant tube heating appliances can be given as an example for this second group of radiant systems. These systems were used widely for total building heating applications in industrial buildings. Examples and explanations for this kind of radiant appliances were given in this study. « Low intensity units are designed to operate below incandescent temperatures and frequently use steel pipe (as used for the calculations in this study) as the emitter. A typical low intensity system may be constructed of 4 inch steel tubing 3,5 m to 16 m in legth with gas combustion units inserted through the top of the tube. Combustion takes place in this tube, elevating the tube temperature to initiate radiant heat emission from the tube surface. Products of combustion are then normally vented to the outside. Low intensity systems are used extensively for heating large structures with Intermediate to high ceilings. Appliances such as manufacturing plants, workshops and in the last years mosques are typical installations effectively utilizing these systems. This study covers the practical and economical study of low intensity gas fired radiant tube heating systems and a comparison with conventional systems. Low intensity gas fired systems are provided with reflectors to direct the radiant energy downward. With this systems, floors and occupants are heated directly. The air is heated indirectly by convection from contact with the warm objects and the floor. The warming of the floor provides additional comfort to the space as the floor reradiates this absorbed heat. It is also important to note that the resulting localized convected air currents are secondary and do not represent heat emitted directly from the heated source. Consequently, air temperature stratification from floor to ceiling is subtiantally reduced. This reduces heat loss through ceiling areas in contrast to heating systems that rely on convected or forced air to distribute heat throughout the space. Due to the high surface temperatures in the building, the building heat losses will be more than for a conventional system. This shows us also the importance of the insulation of the building. Common radiant heating system types and the advantages and disadvantages of these systems have been shown and a comparison have been made between radiant systems and conventional systems. The total heat input required for the selected building has been calculated and a low intensity gas fired linear radiant tube has been selected from the manufacturers catalogue. xvMathematical Model A mathematical model has been developed to calculate the temperatures of the wall Ti, ceiling T2, floor T3 and ambient air Ti. 1. Energy equation for the wall kd*(Td-Ti) + hd*(Ti-Ti) + -^-[Fi2*(E2-Ei) + Fi3*(E3-Ei)] + FRAi*p* - = 0 (8.1) 1-81 Ai 2. Energy equation for the ceiling kç*(Td-T2) + hç*(Ti-T2) + -^-[F2i*(Eı-E2) + F23*(E3-E2)]+FRA2*p*- = 0 (8.2) 1-S2 A2 3. Energy equation for the floor hı*(Tı-T3) + -^-*[F3i*(Eı-E3) + F32*(E2--E3)] + FRA,*p* - = 0 (8.3) 1-83 A3 4. Energy equation for the inside air Aı*hd*(Tı-Tı) + A2*hç*(T2-Tı)A3*ht*(T3-Tı) + f*(Td-Ti)*Q + (1-p)*Q = 0 (8.4) With respect to heat loss to the outside air it is noted that the floor is adiabatic. It does exchange heat by convection with the inside air and radiation exchange with the other surfaces. Unknown temperatures and roots of the above shown nonlinear equation have been solved with the EUREKA Solver software. The calculation has been made for different Q total heat inputs and for different p fraction of radiant heat. All results have been shown in figures, to display the results better. XVIConclusion Calculated results for the gas fired radiant system in this study have been shown in several figures. These are: - Changes between total heat input and inside air temperature, Q - Tj - Changes between total heat input and all temperatures, Q - T(i,2,3,0 - Changes between all temperatures and fraction of radiant heat, T(i 2,3,0 " P - Changes between gas rate and and inside air temperature, Q0 - T\ - Relative prices of radiant heating equipment - Life cycle costs Low intensity radiant heating equipment support an overall reduction in the input energy requirement for radiant heating system installations. Converting energy savings to cost savings demonstrates the cost advantage that is available with radiant heating. As result low intensity radiant heating provides a cost effective, energy efficient alternative for space heating. XVII

Benzer Tezler

  1. Obtaining biogas from Mediterranean pine tree (Pinus pinea) seed shell and plastic catalyst seed shell mixture with pyrolysis process

    Akdeniz çam ağacı (Pinus pinea) tohum kabuğundan ve plastik katalizör tohum kabuğu karışımından piroliz işlemi ile biyogaz elde edilmesi

    NURİ YÖNET

    Doktora

    İngilizce

    İngilizce

    2024

    EnerjiAdana Alparslan Türkeş Bilim Ve Teknoloji Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    DOÇ. DR. ERİNÇ ULUDAMAR

  2. Polimer elektrolit membranlı yakıt pili uygulamaları için poli(arilen eter) esaslı membranların hazırlanması

    Preparation of poly(arylene ether) based polymer electrolyte membranes for fuel cell applications

    MERVE GÜRTEKİN SEDEN

    Doktora

    Türkçe

    Türkçe

    2013

    KimyaMarmara Üniversitesi

    Kimya Ana Bilim Dalı

    PROF. DR. NİLHAN KAYAMAN APOHAN

    DOÇ. DR. TÜLAY İNAN

  3. Piston ve supapları cr2o3 kaplanmış ve farklı yakıt katkıları kullanılan bir dizel motorda performans ve emisyon değerlerinin yapay sinir ağları ile belirlenmesi

    Determination of diesel engine performance and emission values using pistons and valves cr2o3 coated and different fuel additives using artificial neural networks

    HÜSEYİN SEVİNÇ

    Yüksek Lisans

    Türkçe

    Türkçe

    2018

    Mühendislik BilimleriFırat Üniversitesi

    Otomotiv Mühendisliği Ana Bilim Dalı

    PROF. DR. HANBEY HAZAR

  4. Utilization of an ammonia cracker for generation of NH3/H2 fuel mixture

    Amonyak kırılmasının NH3/H2 yakıt karışımı üretiminde kullanılması

    HARETH MOTHANNA RASHED ALFEEL

    Yüksek Lisans

    İngilizce

    İngilizce

    2023

    Makine MühendisliğiGebze Teknik Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ RECEP ÖNLER

  5. Elektrikli araçlarda yapay sinir ağı tabanlı batarya sağlık durumu kestirimi

    State of health estimation in electric vehicles based on artificial neural network

    MUSTAFA DİNEK

    Yüksek Lisans

    Türkçe

    Türkçe

    2021

    Mekatronik Mühendisliğiİstanbul Teknik Üniversitesi

    Mekatronik Mühendisliği Ana Bilim Dalı

    DOÇ. DR. SERHAT İKİZOĞLU