Geri Dön

İmplant üstü dijital ölçülerde tarama gövdelerinde yapılan modifikasyonun dijital ölçü hassasiyetine etkisi: In vitro çalışma

The effect of scanbody modifications on digital impressions onimplants on digital impression accuracy: In vitro study

  1. Tez No: 763503
  2. Yazar: SEMA MERVE UZEL
  3. Danışmanlar: DOÇ. DR. MUSTAFA BARIŞ GÜNCÜ
  4. Tez Türü: Diş Hekimliği Uzmanlık
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Ağız, Dental implantasyon, Dental implantlar, Sayısal tarayıcılar, Mouth, Dental implantation, Dental implants, Digital scanners
  7. Yıl: 2022
  8. Dil: Türkçe
  9. Üniversite: Hacettepe Üniversitesi
  10. Enstitü: Diş Hekimliği Fakültesi
  11. Ana Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

İmplant üstü restorasyonların dijital iş akışı ile yapılmasında kullanılan tarama gövdelerinde yapılan modifikasyonların ölçü hassasiyetine etkisi ile ilgili literatürde yeterli bilgi yoktur. Bu çalışmanın amacı, farklı ağız içi tarayıcılarla alınan dijital ölçülerde tarama gövdelerinde yapılan modifikasyonların ölçü hassasiyetine olan etkisini incelemektir. Bu amaçla, üç boyutlu yazıcıdan üretilen parsiyel üst çene dişsiz modele iki adet implant yerleştirilmiştir. İmplantların üç boyutlu konumu belirlemek içi laboratuvar tarayıcısı ile tarama yapılıp referans veri kümesi elde edilmiştir. Çalışmada tarama gövdelerinde yapılan modifikasyonlara göre 4 grup oluşturulmuştur: Grup 1; modifikasyon yapılmamıştır, Grup 2; proksimal yüzeyden 2x3 mm genişliğinde alan ile çıkartılmıştır, Grup 3; proksimal yüzeyden 3x4 mm genişliğinde alan çıkartılmıştır, Grup 4; vida giriş yuvasını bir bölümünü kapsayan 3x6 mm genişliğinde alan çıkartılmıştır. Her grupta üç farklı ağız içi tarayıcı (Itero Element 2, 3shape Trios 4, Medit i500) ile dijital ölçü alınmıştır (n=10). Ağız içi tarayıcılardan elde edilen dijital veriler, referans veri kümesi ile matematiksel çakıştırma algoritma programı kullanılarak ölçü hassasiyeti değerlendirilmiştir. Sonuçların değerlendirilmesi için Mann-Whitney U non-parametrik istatistiksel analiz testi kullanılmıştır. Ağız içi tarayıcıdan bağımsız olarak her iki implant bölgesinde de gruplar arasında istatistiksel olarak anlamlı fark bulunmuştur (p<0.05). Grup içi karşılaştırmalarda ağız içi tarayıcılar arasında Grup 1 ve 2'de anlamlı bir fark bulunmazken (p>0.05), Grup 3 ve 4'te tarayıcılar arasında anlamlı fark bulunmuştur (p<0.05). Açısal sapma değerleri incelendiğinde ise her iki implant bölgesi için cihazlar arası istatistiksel fark anlamlı değildir (p>0.05). Tarama gövdelerinde yapılan modifikasyonlar ölçü hassasiyetini etkilemektedir. Ağız içi tarayıcıların, bölümlü dişsizliklerdeki implant üstü dijital ölçü hassasiyeti benzerdir.

Özet (Çeviri)

There is not enough information in the literature on the effect of modifications made on the scanbodies used in the digital workflow of implant restorations on the impression accuracy. The aim of this study is to examine the effect of the modifications made on the digital impressions taken with different intraoral scanners on the impression accuracy. For this purpose, two implants were placed in the partial maxillary edentulous model produced by a 3D printer. In order to determine the three-dimensional position of the implants, scanning was performed with a laboratory scanner and a reference dataset was obtained. In the study, 4 groups were formed according to the modifications made to the scan bodies: Group 1; no modifications were made, Group 2; A 2x3 mm wide area was excised from the proximal surface, Group 3; A 3x4 mm wide area was excised from the proximal surface, Group 4; The 3x6 mm wide area covering part of the screw entry slot has been removed. Digital impressions were taken with three different intraoral scanners (Itero Element 2, 3shape Trios 4, Medit i500) in each group (n=10). The digital data obtained from intraoral scanners, the reference data set and the measurement precision were evaluated by using the mathematical registration algorithm program. Mann-Whitney U non-parametric statistical analysis test was used to evaluate the results. A statistically significant difference was found between the groups in both implant sites, independent of the intraoral scanner (p<0.05). While there was no significant difference between intraoral scanners in Groups 1 and 2 (p>0.05), a significant difference was found between scanners in Groups 3 and 4 (p<0.05). When the angular deviation values are examined, the statistical difference between the devices for both implant regions is not significant (p>0.05). Modifications made to the scanning bodies affect the measurement accuracy. The accuracy of intraoral scanners on the implant in partial edentulism is similar.

Benzer Tezler

  1. Farklı tarama gövdelerinin ve diş eti yüksekliklerinin dijital ölçü sonrası implantın konumlandırma doğruluğu üzerine etkisi

    The effect of different scan bodies and gingival heights on implant positioning accuracy after digital impression

    CANSU BOLAT

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2024

    Diş HekimliğiHatay Mustafa Kemal Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ BİLGE ERGÜNBAŞ

  2. Maksillomandibular tam dişsiz arklarda implant pozisyonunun ölçü tekniğinin doğruluğuna etkisi

    The effect of implant number and position on the accuracy of the impression technique in maxillomandibular total edentulous arches

    MELEK SULTAN KİRAZ

    Doktora

    Türkçe

    Türkçe

    2022

    Diş HekimliğiGazi Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    DOÇ. DR. PINAR ÇEVİK

  3. Dijital ölçü aşamasında kullanılan titanyum ve peek tarama gövde materyallerinin yer değiştirmeye bağlı hassasiyetinin değerlendirilmesi

    Evaluation of displacement precision of titanium and peek scan body materials used in digital impression

    EMRE DİKER

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2021

    Diş HekimliğiAnkara Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. SEDAT HAKAN TERZİOĞLU

  4. Tam ark implant üstü dijital ölçü doğruluğuna yardımcı yöntemlerin etkisinin İn Vitro olarak incelenmesi

    In vitro investigation of the effects of auxiliary methods on the accuracy of full-arch implant digital impressions

    HAFİZE DİZEK

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2024

    Diş Hekimliğiİzmir Katip Çelebi Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. SÜLEYMAN AGÜLOĞLU

  5. Dijital implant ölçü netliğinin artırılmasına etkili parametrelerin incelenmesi

    Evaluation of the parameters effecting the accuracy of digital implant impressions

    GÖRKEM GÖKSOY

    Doktora

    Türkçe

    Türkçe

    2024

    Diş Hekimliğiİstanbul Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. BİLGE GÖKÇEN RÖHLİG