Manyetik rezonans görüntüleme magnetlerinin yüksek sıcaklık süperiletken şeritlerden kavramsal tasarımı ve çoklu fizik analizleri

Conceptual design and multiphysics analysis of magnetic resonance imaging magnets by high temperature superconducting tapes

  1. Tez No: 769626
  2. Yazar: HÜSNÜ KARA
  3. Danışmanlar: PROF. DR. FEDAİ İNANIR, DOÇ. DR. ÖNDER YARGI
  4. Tez Türü: Doktora
  5. Konular: Bilim ve Teknoloji, Fizik ve Fizik Mühendisliği, Science and Technology, Physics and Physics Engineering
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2022
  8. Dil: Türkçe
  9. Üniversite: Yıldız Teknik Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Fizik Ana Bilim Dalı
  12. Bilim Dalı: Fizik Bilim Dalı
  13. Sayfa Sayısı: 102

Özet

MRG için aktif olarak korunan geniş çaplı bir mıknatıs sistemi tasarlanmıştır.COMSOL Multiphysics'in gradyan tabanlı optimizasyon çözücüsü, MRG sisteminde simetrik elektromıknatısların optimum geometrik düzenlemesini elde etmek için kullanılmıştır. Yüksek ve homojen bir manyetik alan oluşturmak için, on çift pankek bobine (ÇPB) sarılmış ikinci nesil (2G) nadir toprak baryum-bakır-oksit (REBCO) yüksek sıcaklık süperiletkeni (YSİ) kullandık. ÇPB setlerinin boyutları, REBCO YSİ şeritlerinin boyutu dikkate alınarak seçilmiştir ve optimize edilmiş tasarım çözümü, her ÇPB setinde manyetik alan, kaçak alan ve YSİ şeritlerinden geçen akımı sağlar. 1.5 T aktif korumalı bir mıknatısın tasarım detaylarını sunuyoruz. 200 mm DSV'de 1.23 ppm'lik homojensizlik ve 5 m mesafenin dışında 0.05 G kadar düşük bir kaçak alan elde edildi. Ek olarak, ÇPB setlerinde 2.40 T'lik düşük bir tepe alanı elde edilmiştir, bu da“quench”koruması için faydalıdır. Bu düşük homojensizlik, daha yüksek bir sinyal-gürültü oranı ve sonuç olarak daha hızlı görüntü toplama ve daha iyi görüntü kalitesi sağlar. Bu, hastalıkların daha erken aşamalarda teşhis ve tedavi edilebileceği anlamına gelir. Sonuçlarımız, REBCO YSİ kullanan bu MRG mıknatıs tasarımının klinik tanıda kullanım için uygun olduğunu ve oluşturulabileceğini göstermektedir. Ayrıca üçüncü bölümde tasarlanmış olan perdelemeli magnet tasarımları için AC transport kayıp analizinin yanı sıra elektro-termal ve elektro-mekanik analizler gerçekleştirilmiştir.

Özet (Çeviri)

An actively shielded wide-bore magnet system has been designed for magnetic resonance imaging. The gradient-based optimization solver of COMSOL Multiphysics has been used to obtain an optimum geometrical arrangement of symmetrical electromagnets in the MRI system. To generate a high and homogeneous magnetic field, we employed a second-generation (2G) rare-earth barium-copper-oxide (REBCO) high-temperature superconductor (HTS) which was wound into ten double pancake coils (DPC). The dimensions of the DPC sets have been chosen considering the size of REBCO HTS tapes, and the optimized design solution provides magnetic field, stray field, and current passing through the HTS tapes on each DPC set. We present the design details of a 1.5 T actively shielded magnet. The inhomogeneity of 1.23 ppm in the 200 mm DSV and a stray field of as low as 0.05 G outside of the 5 m distance were achieved. Additionally, a low peak field of 2.40 T in DPC sets has been accomplished, which is beneficial for“quench”protection. This low inhomogeneity provides a higher signal-to noise ratio and, consequently, faster image collection and better image quality. This means that diseases can be diagnosed and treated at earlier stages. Our results show that this MRI magnet design using REBCO HTS is suitable for use in clinical diagnosis and could be constructed. In addition, AC transport loss analysis as well as electro-thermal and electro-mechanical analyzes were carried out for the shielded magnet designs designed in the third section.

Benzer Tezler

  1. Manyetik rezonans görüntüleme teknikleri

    Magnetic resonance imaging techniques

    SERKAN ERİŞ

    Yüksek Lisans

    Türkçe

    Türkçe

    2008

    Radyoloji ve Nükleer TıpPamukkale Üniversitesi

    Fizik Ana Bilim Dalı

    PROF. DR. HASAN ERDOĞAN

  2. Manyetik rezonans görüntüleme yöntemi ile fetal santral sinir sistemi ve ilişkili anomalilerin tespiti ve değerlendirilmesi

    Detection and evaluation of fetal central nervous system and related patologies with magnetic resonance imaging

    ZUHAL CANDAN ERENLER

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2009

    Radyoloji ve Nükleer TıpOndokuz Mayıs Üniversitesi

    Radyodiagnostik Ana Bilim Dalı

    YRD. DOÇ. DR. MELTEM CEYHAN

  3. Cerebellum ve ventral pons volümüne yaş ve cinsiyetin etkisi; prospektif bir MR çalışması

    Effects of age and gender on the cerebellum and the ventral pons volume- a prospective MR study

    RABİA GÖKALP

    Yüksek Lisans

    Türkçe

    Türkçe

    2008

    AnatomiSelçuk Üniversitesi

    Anatomi Ana Bilim Dalı

    DOÇ. DR. İ.İLKNUR UYSAL

  4. The design of an optically powered low voltage CMOS receiver for magnetic resonance imaging

    Manyetik rezonans görüntüleme için optik güçle çalışan düşük voltajlı CMOS alıcı tasarımı

    AHMED AKSU

    Yüksek Lisans

    İngilizce

    İngilizce

    2024

    Elektrik ve Elektronik MühendisliğiBoğaziçi Üniversitesi

    Elektrik-Elektronik Mühendisliği Ana Bilim Dalı

    PROF. DR. GÜNHAN DÜNDAR

    PROF. DR. ARDA DENİZ YALÇINKAYA

  5. Electromagnetic MEMS switch for MRI detuning circuits

    MRI detuning devreleri için elektromanyetik MEMS anahtarı

    GÖKBERK KEREM DEMİR

    Yüksek Lisans

    İngilizce

    İngilizce

    2024

    Elektrik ve Elektronik MühendisliğiBoğaziçi Üniversitesi

    Elektrik-Elektronik Mühendisliği Ana Bilim Dalı

    PROF. DR. ARDA DENİZ YALÇINKAYA