Geri Dön

Farklı dental tarayıcılardan elde edilen kayıtların farklı üç boyutlu yazıcı çıktılarının uyumlarının incelenmesi

The analysis of compatibility of the output from different 3D printers in relation to the data obtained from different dental scanners

  1. Tez No: 774380
  2. Yazar: BERKEHAN TUNÇEL
  3. Danışmanlar: DOÇ. DR. SEDEN AKAN BAYHAN
  4. Tez Türü: Doktora
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Dental tarayıcılar, Diş hekimliği, Ortodonti, Ortodontik aygıtlar, Sayısal tarayıcılar, Tarayıcılar, Üç boyutlu yazıcı, Dental scanners, Dentistry, Orthodontics, Orthodontic appliances, Digital scanners, Scanners, Three dimensional printer
  7. Yıl: 2022
  8. Dil: Türkçe
  9. Üniversite: Altınbaş Üniversitesi
  10. Enstitü: Lisansüstü Eğitim Enstitüsü
  11. Ana Bilim Dalı: Ortodonti Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

AMAÇ: Bu çalışmanın amacı dental sektörde kullanılan farklı tarayıcı türleri ile farklı yazıcı türlerinin uyumlarını araştırmaktır. Bu çalışma, kliniğe yeni alınan teknolojik materyal ile eskilerinin entegre edilip edilemeyeceğini ve üreticilerin önerdiği yeni teknolojilerin de alınmasının zorunlu olup olmadığının incelemesini içermektedir. 3D yazıcılar ile elde edilen modeller alçı modellerin yerini alacağından, bunların istatistiksel olarak doğruluğunu ve bu sonuçların klinik olarak anlamlı olup olmadığını araştırmak önemlidir. GEREÇ VE YÖNTEM: 3'ü ağız içi, 1'i masaüstü tarayıcı olmak üzere 4 farklı dental tarayıcı (iTero, Trios 3, PrimeScan, E1) ile tek bir typodont model üzerinden tarama yapılarak farklı .stl formatlar elde edilmiştir. Daha sonra bu .stl formatlar 4 farklı 3D yazıcıya (SLA, mSLA, DLP, FDM) gönderilmiş ve toplamda 32 çene modeli elde edilmiştir. Typodont ve üretilen modeller üzerinden XYZ düzlemleri üzerinde farklı ölçümler yapılarak bu ölçümlerin ortalamaları üzerinden uyumları değerlendirilmiştir. Ölçümler dijital dental kaliper yardımı ile gerçekleştirilmiştir. Ölçümler arasındaki uyumun incelenmesinde Sınıf İçi Korelasyon Katsayısı (ICC) kullanılmıştır. BULGULAR: 4 farklı yazıcıdan elde edilen ölçümler typodont modelden elde edilen ölçümlerle karşılaştırıldığında tüm düzlemlerde istatistiksel olarak anlamlı farklılıklar elde edilmiştir (p<0,001). Sagittal ölçümlerde yazıcılar ile typodont model karşılaştırıldığında tüm tarayıcılarda mükemmel uyum gözlemlenmiştir. Transversal düzlemde ise en iyi uyumu 3Shape Trios 3 ile SLA kombinasyonu göstermiştir. İstatistiksel olarak tarayıcı yazıcı kombinasyonlarında en farklı değerler vertikal düzlemde gözlemlenmiştir. SONUÇ: Bu çalışma, farklı 3D yazıcıların farklı tarayıcılar ile klinik olarak kabul edilebilir doğruluk seviyeleri üretebileceğini göstermiştir. XYZ düzlemlerinde, tarayıcılar ile yazıcıların kombinasyonları karşılaştırıldığında 3Shape Trios 3 ile SLA istatistiksel olarak diğerlerine kıyasla en iyi uyumu göstermiştir. Bu uyumu 3Shape Trios 3 ile DLP kombinasyonu takip etmiştir. Klinik kullanımda tüm yazıcılar tarayıcılar ile iyi uyum gösterirken FDM aralarında en son tercih edilecek yazıcı olarak bulunmuştur.

Özet (Çeviri)

AIM: The purpose of this study is to investigate the compatibility of different scanner types and different printer types used in the dental sector. This study includes the examination of whether the new technological materials purchased for the clinic can be integrated with old ones and whether it is necessary to purchase the new technologies suggested by the manufacturers. Since the models obtained with 3D printers will replace the plaster models, it is important to investigate their statistical accuracy and whether these results are clinically meaningful. MATERIAL AND METHOD: Different .stl formats were obtained by scanning a single typodont model with 4 different dental scanners (iTero, Trios 3, PrimeScan, E1), 3 of which are intraoral and 1 of which is desktop scanner. Then, these .stl formats were sent to 4 different 3D printers (SLA, mSLA, DLP, FDM) and a total of 32 jaw models were obtained. Different measurements were made on the XYZ planes on the Typodont and printed models, and their compatibility was evaluated over the averages of these measurements. Measurements were made manually with a digital dental caliper. Intra-Class Correlation Coefficient (ICC) was used to examine the compatibility between the measurements. RESULTS: When measurements obtained from 4 different printers were compared with measurements obtained from typodont model, statistically significant differences were obtained in all planes (p<0,001). Comparing printers and typodont model in sagittal measurements, a perfect match was observed in all scanners. In the transversal plane, the combination of 3Shape Trios 3 and SLA showed the best compatibility. Statistically, the most different values in scanner-printer combinations were observed in vertical plane. CONCLUSION: This study showed that different 3D printers can produce clinically acceptable accuracy with different scanners. When comparing combinations of scanners and printers in XYZ planes, 3Shape Trios 3 and SLA showed the best match statistically compared to others. This harmony was followed by the combination of 3Shape Trios 3 and DLP. In clinical use, while all printers are well compatible with scanners, FDM has been found to be the last preferred printer among them.

Benzer Tezler

  1. Farklı ağız içi tarayıcılar ile alınan tek ve çift taraflı kapanış kaydının kayıt doğruluğuna etkisi

    The effect of unilateral and bilateral bite recording with different intraoral scanners on recording accuracy

    YUSUF KAMİL ŞEKER

    Doktora

    Türkçe

    Türkçe

    2026

    Necmettin Erbakan Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    Yükleniyor...

  2. Bazı esterlerin kinetik incelenmesi ve termodinamik parametrelerin belirlenmesi

    Kinetic study and detesmination of thermodnamic parameters of some esters

    İBRAHİM TAŞ

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    Uludağ Üniversitesi

    Kimya Ana Bilim Dalı

    Yükleniyor...

  3. İzmir'de bazı yolların kapatılarak yaya bölgeleri oluşturma da kent peyzajını geliştirme açısından yeniden planlanması üzerinde araştırmalar

    Başlık çevirisi yok

    BAHAR TÜRKYILMAZ

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    Ege Üniversitesi

    Şehir ve Bölge Planlama Ana Bilim Dalı

    Yükleniyor...

  4. Testosteron dihidrotestosteron ve östrojenin benign prostat hiperplazisindeki etyolojik rolleri

    The roles of testosterone, dihydrotestosterone and estradiole on the etiology of benign prostatic hyperplasia

    HALUK TOKUÇOĞLU

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1986

    Gazi Üniversitesi

    Üroloji Ana Bilim Dalı

    Yükleniyor...

  5. Süt formüllerinin tüketim uygulamaları ve süt formüllerinin C vitamini içeriği ile pH değerleri

    Başlık çevirisi yok

    GÖNÜL VAROL

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    İstanbul Üniversitesi

    Çocuk Gelişimi Ana Bilim Dalı

    Yükleniyor...