Comparison of implant-like cylindrical rods with four different surgical implant guides by 3D imaging methods

Dört farklı cerrahi implant klavuzu ile yerleştirilen implant benzeri silindirik çubukların 3B görüntüleme yöntemi ile karşılaştırılması

  1. Tez No: 778954
  2. Yazar: BERK TOLONAY
  3. Danışmanlar: DOÇ. DR. EDİZ DENİZ
  4. Tez Türü: Doktora
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Dental implantasyon, Dental implantlar, Kılavuzlar, Üç boyutlu görüntüleme, Dental implantation, Dental implants, Guides, Three dimensional imaging
  7. Yıl: 2022
  8. Dil: İngilizce
  9. Üniversite: Yeditepe Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Ağız, Diş ve Çene Cerrahisi Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Dental implant tedavisinin amacı eksik bir diş kökünü tamamlamaktır. Dental implant yerleştirmek cerrahi bir prosedürdür. Dental implantların başarısını pek çok etken değiştirebilir ama bu etkenlerden biri implantın konumudur ve cerrahın tecrübesi ile de ilişkilidir. Hastanın konforunu arttırmak ve cerrahın yanlış konumlandırma ihtimalini azaltmak için implant uygulama klavuzları dünya çapında kullanılır. Klavuzlar günümüzde reçine ile üretilmektedir. Bu çalışmanın amacı üç farklı filament şeklinde üretilmiş malzeme ile reçineyi klavuz üretim malzemesi olarak kıyaslamaktır. Bu çalışmayı yapmak için ABS, PET, PLA ve Reçine olmak üzere dört farklı ana deney grubu vardır. 2 cm, 5 cm ve 10 cm olarak sırasıyla tek kuron, köprü restorasyonu ve total dişsiz bir ağızı temsil eden farklı boyutlarda 3 alt grup vardır. Her alt grup için 10 adet toplamda 120 adet deney düzeneği vardır. İmplantın boyun ve apeks kısmında çizgisel sapmaya gövdesinde ise açısal sapmaya bakılmıştır. ABS, PET ve PLA filamentler BASF 3D Printing Solutions GmbH firmasından temin edilmiş ve Creality CR-10 v3 yazıcısı kullanılarak yazılmıştır. Reçine klavuzlar Straumann tarafından temin edilmiştir. Her deney düzeneği implant angldruvası ile 500 rpm hızda ve 20 N/cm torkta sıvı irrigasyon ile frezlenmiştir. Her düzenek frezlendikten sonra boşluklara pin yerleştirilmiş ve NewTom CT ile görüntülenmiştir. İstatistiksel analizler NCSS (Number Cruncher Statistical System) 2007 (Kaysville, Utah, USA) yazılımı ile yapılmıştır. Sonuçlar p<0.05 ve p<0.01 anlamlılık düzeyinde değerlendirilmiştir. Çizgisel sapma ve açı farklılığı konusunda istatistiksel olarak anlamlı ve en iyi sonuçlar boyut olarak 10 cm grubunda çıkmıştır. Bu anlamda 2 cm grubu 5 cm grubundan daha iyi sonuç vermesine rağmen çıkan farklar istatistiksel olarak anlamlı bulunmamıştır. Aynı boyutta farklı malzemelerin değerlendirilmesinde farklılıklar vardır ancak istatistiksel olarak anlamlılık yoktur. PET deneylerde daha iyi sonuçlar verirken en kötü sonuçlar ABS'de bulunmuştur.

Özet (Çeviri)

The purpose of implant treatment is to replace a missing tooth root. Implant placement is a surgical procedure. Many factors can affect implant success but one of them is the place of the implant which is also related with the experience of the operator. Eliminating surgical discomfort for the patient and misplacing possibility for the operators implant application guides are used world-wide. Guides are made of resin already. The aim of this study is to compare three filament-based materials and resin as a choice of material in guide production. In order to do that four main test groups are designed which are ABS, PET, PLA, and Resin. Three subgroups with 2 cm, 5 cm and 10 cm edge squares were created representing single crown, bridge restoration and totally edentulous mouth, respectively. Each subgroup has 10 samples and there are a total number of 120 samples. Linear deviations at the top and the apex of the implant and angular changes of the implants were observed. ABS, PET, and PLA were supplied from BASF 3D Printing Solutions GmbH and printed in Creality CR-10 v3. Resin guides were provided by Straumann. Each test subject was drilled by implant driver at 500 rpm 20 N/cm torque with irrigation. A pin (1,3mm in diameter and 27,95 mm in length) was placed into the socket scanned with NewTom CT. Statistical analyses were performed with NCSS (Number Cruncher Statistical System) 2007 (Kaysville, Utah, USA) software. The results were evaluated at the significance level of p<0.05 and p<0.01. Best results were received in 10 cm group in linear and angular deviations. 2 cm groups are better in linear and angular deviations than 5 cm, but the difference was not statistically significant. There were no statistically significant difference in the same size between different materials. PET generally gave better scores than the others while ABS did the worse.

Benzer Tezler

  1. Rezorbe olmuş tam dişsiz üst çenenin farklı açı ve konumda implant uygulamaları ile alternatif tedavi seçeneklerinin sonlu elemanlar analiz yöntemi ile karşılaştırılması

    The comparison of alternative treatment methods for rehabilitating resorbed total edentulous maxilla with dental implants in different angle an positions by implementing finite element analysis

    VOLKAN ATAK

    Doktora

    Türkçe

    Türkçe

    2018

    Diş HekimliğiGazi Üniversitesi

    Ağız, Diş ve Çene Cerrahisi Ana Bilim Dalı

    PROF. DR. GÖKHAN HAKKI ALPASLAN

  2. 6-11 yaş arası normal işiten, koklear implant ve işitme cihazı kullananların işaretleme testi performanslarının karşılaştırılması

    Comparison of verbal and nonverbal cancellation test performance between 6-11 years old with normal hearing, cochlear implant and hearing aid users

    MERVE KOÇAK SİLİSTRE

    Yüksek Lisans

    Türkçe

    Türkçe

    2019

    Kulak Burun ve BoğazEge Üniversitesi

    Kulak Burun Boğaz Ana Bilim Dalı

    PROF. DR. CEM BİLGEN

  3. Farklı implant- abutment bağlantılarının çiğneme kuvvetleri altında yorgunluk, kırılganlık dayanımlarının in-vitro olarak incelenmesi

    The in-vitro comparison of fracture resistance in dental implant-abutment connection using two different implant systems besides chewing forces

    SELİN KIPIRDI

    Doktora

    Türkçe

    Türkçe

    2013

    Diş Hekimliğiİstanbul Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    DOÇ. DR. BİLGE GÖKÇEN RÖHLİG

  4. 60-72 aylık işitme kayıplı ve işitme kayıplı olmayan çocuklarda erken okuryazarlık becerilerinin karşılaştırılması

    A comparison of early literacy skills in 60-72 month-old children with hearing loss and their peers without hearing loss

    FATMA ZEHRA SAATCI

    Yüksek Lisans

    Türkçe

    Türkçe

    2019

    Kulak Burun ve BoğazKto Karatay Üniversitesi

    Odyoloji Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ İCLAL ŞAN

  5. Comparıson of bıoactıvıtıes of Ti6Al4V ımplants after multıple surface treatments

    Çoklu yüzey işlemleri uygulanan Ti6Al4V implantların biyoaktivitelerinin karşılaştırılması

    NEŞE BENAY SEKEN

    Yüksek Lisans

    İngilizce

    İngilizce

    2025

    Mühendislik Bilimleriİstanbul Teknik Üniversitesi

    Nanobilim ve Nanomühendislik Ana Bilim Dalı

    PROF. DR. NİLGÜN BAYDOĞAN