Geri dönüştürülmüş kemik modellerinde; transvers ve basamaklı osteotomilerin biyomekaniksel olarak karşılaştırılması
Biomechanical comparison of transverse and step-cut osteotomies in recycled bone models
- Tez No: 808472
- Danışmanlar: DOÇ. DR. TOLGA TOLUNAY
- Tez Türü: Tıpta Uzmanlık
- Konular: Ortopedi ve Travmatoloji, Orthopedics and Traumatology
- Anahtar Kelimeler: Geri dönüştürülmüş kemik, transvers osteotomi, basamaklı osteotomi, biyomekanik, aksiyel kompresyon, burulma, malign kemik tümörleri, Recycled bone, transverse osteotomy, Step-cut osteotomy, biomechanic, axial compression, torsion, malignant bone tumors
- Yıl: 2023
- Dil: Türkçe
- Üniversite: Gazi Üniversitesi
- Enstitü: Tıp Fakültesi
- Ana Bilim Dalı: Ortopedi ve Travmatoloji Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
Giriş ve Amaç: Çalışmamızda amaç olarak geri dönüştürülmüş kemik cerrahisinde geleneksel olarak kullanılan; kemik sınırlarda basit transvers osteotomi yerine basamaklı osteotomi tekniği kullanmanın, geri dönüştürülmüş kemiğin internal tespiti sonrası mekanik özelliklerini incelemektir. Gereç ve Yöntem: Çalışmada 28 adet güçlendirilmiş üçüncü kuşak kompozit sentetik sağ femur modelleri kullanıldı. Birinci gruptaki 14 adet femur; lateral femoral epikondilin en distal ucundan proksimale doğru 6. cm distal cerrahi sınır olarak ve distalden 20. cm proksimal cerrahi sınır olarak işaretlendi. Transvers gruptaki modellere bu seviyeden transvers olarak kesici motor yardımı ile osteotomi uygulandı. İkinci gruptaki 14 femur ise aynı seviyelerden cerrahi sınır olarak işaretlendi. Takiben koronal planda ters Z şekli oluşturacak şekilde, altta ve üstte 90 derece basamak oluşturacak biçimde ve basamak boyu 1 cm olmak üzere işaretlenerek kesici motor yardımı ile osteotomi yapıldı. Basamaklar oluşturulurken cerrahi sınır güvenliğini korumak adına basamak oluşturulan yön distalde distal tarafa ve proksimalde proksimal tarafa doğru hesaplandı. Bütün kemik modelleri aynı yer, aynı seviye ve konfigürasyonda distal femur lateral plak vida ile tespit edildi. Her iki gruptaki eşdeğer 14 model aksiyel kompresyon ve burulma(torsiyon) testine tabi tutulmak üzere iki gruba ayrıldı. Bulgular: Elde edilen veriler karşılaştırıldığında aksiyel yüklenme testlerindeki rijitlik (0.0728) , maksimum yük (0.9015) ve maksimum yükteki deplasman (0.5350) açısından istatistiksel olarak anlamlı bir fark bulunamamıştır (p<0.05). Burulma testlerindeki rijitlik (0.0926) ve maksimum torktaki açı (0.1649) 98 değerleri açısından da istatistiksel olarak anlamlı bir fark bulunmamasına rağmen, maksimum tork değerleri açısından (0.0069) istatistiksel olarak basamaklı osteotomi grubunda daha yüksek olmak üzere anlamlı fark bulunmuştur. Sonuç ve Öneriler: Geri dönüştürülmüş kemik modellerinde basamaklı osteotomi uygulamak osteotomi redüksiyonunu kolaylaştıran, kaynamamayı azaltması beklenen ve torsiyonel stabiliteyi de arttıran etkin ve uygun bir yöntem olarak kullanılabilecektir.
Özet (Çeviri)
Introduction and Goal: The aim of our study is to investigate the mechanical properties of recycled bone, following internal fixation by comparing the traditional use of simple transverse osteotomy at the bone margins with the technique of step-cut osteotomy in recycled bone surgery. Material and Method: In the study, 28 reinforced third generation composite synthetic right femur models were used. The first group comprised 14 femurs, with the surgical safe zones marked as 6. cm proximal from the distal tip of the lateral femoral epicondyle as the distal surgical boundary and 20. cm proximal from the distal tip of the lateral femoral epicondyle as the proximal surgical boundary. Transverse osteotomies were perfomed on the models in the transverse gruop at this level using a oscillating saw. The second group of 14 femurs was also marked at the same levels as the surgical boundaries. Subsequently, osteotomies were performed using oscillating saw, creating a reverse z-shaped configuration in the coronal plant with a 90 degree step both above and below, and a step lentgh of 1 centimeter. While creating the steps, the direction of step was determined to maintain surgical boundary integrity, wtih steps oriented distally towars the distal side and proximally towars the proximal side. All bone models were fixed with a distal femoral lateral plate and screws at the same location, level and configuration. The equivalent 14 models from each group were divided into two groups to undergo axial compression and torsion tests. Findings: When the acquired data were compared, no statistically significant difference was found in terms of stiffness (0.0728), maximum load (0.9015), and displacement at maximum load (0.5350) in axial loading tests (p<0.05). Although there was no statistically significant difference in terms of 100 stiffness (0.0926) and angle at maximum torque in torsion tests (0.1649), a significant difference was found in terms of maximum torque values (0.0069), which were higher in the step-cut osteotomy group. Conclusion and Recommendations: Applying step-cut osteotomy in recycled bone models can be used as an effective and suitable method that facilitates osteotomy reduction, reduces non-union rates, and increases torsional stability
Benzer Tezler
- Dokuma kumaşlarda örgü tipinin ham kumaşın boyutları ve geometrik özellikleri üzerindeki etkilerinin araştırılması
Başlık çevirisi yok
EMEL ÖNDER
- Bir pamuk iplikhanesinde fiili çalışma metodlarının incelenmesi ve mevcut işlemlerin standart sürelerinin saptanması
Başlık çevirisi yok
MÜRŞİDE KESEROĞLU
- An Experimental and analytical investigation of cam follower jump phenomenon
Başlık çevirisi yok
ŞÖLEN ŞEN
Yüksek Lisans
İngilizce
1987
Orta Doğu Teknik ÜniversitesiMakine Mühendisliği Ana Bilim Dalı
Yükleniyor...