Camilerde ısıl konfor ve iç ortam hava kalitesinin tespiti ve ısıtma soğutma enerji tüketiminin azaltılması için farklı stratejilerin değerlendirilmesi

Investigation of thermal comfort and indoor air quality in mosques and evaluation of heating and cooling strategies for energy consumption reduction

  1. Tez No: 823540
  2. Yazar: AHMET YÜKSEL
  3. Danışmanlar: PROF. DR. MÜSLÜM ARICI
  4. Tez Türü: Doktora
  5. Konular: Enerji, Makine Mühendisliği, Energy, Mechanical Engineering
  6. Anahtar Kelimeler: Enerji, Enerji tüketimi, Energy, Energy consumption
  7. Yıl: 2023
  8. Dil: Türkçe
  9. Üniversite: Kocaeli Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Makine Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Evler, ofisler ve işyerleri gibi sürekli kullanım alanlarının enerji tüketimindeki payı fazla olsa da aralıklı olarak kullanılan ibadethaneler gibi yapıların sayısı günden güne artığı için enerji tüketimindeki payı göz ardı edilmemelidir. Bu tez çalışmasında, Yalova/Türkiye'de bulunan, orta ölçekli tipik bir mahalle camisini temsil eden Hacı Hasan Sert Cami'nin farklı iklim şartlarında ve doluluk oranlarında kullanıldığı Cuma, Bayram, Teravih ve vakit namazlarında meydana gelen mevcut ısıl konfor, iç hava kalitesi ve enerji tüketimleri deneysel olarak incelenmiştir. Ayrıca mevcut konfor şartlarının daha az enerji sarfiyatıyla sağlanması amacıyla iklimlendirme sistemleri kullanım stratejilerini barındıran senaryolar oluşturulmuş ve simüle edilmiştir. Çalışmada, iklimlendirme sistemlerinin çalışma stratejisine ve doluluk oranlarına bağlı olarak camideki en sağlıklı ve konforlu şartların daha az enerji tüketimi ile sağlanması amaçlanmıştır. Deneysel çalışmalar, cemaat sayısındaki ve caminin kullanım süresindeki artışın ısıl konfor üzerinde kış ayları için olumlu, yaz ayları için ise olumsuz etkileri olduğunu göstermiştir. Pencereler kapalı iken caminin yüksek doluluk oranında kullanımı, CO2 konsantrasyonunun 3500 ppm'e kadar artmasına sebep olmuştur. En düşük ve en yüksek PM konsantrasyonları ile sırasıyla sabah ve yatsı namazları sonrasında karşılaşılmıştır. Dolayısıyla halıların süpürülmesi işlemi için en uygun zamanın sabah namazından sonra olduğu belirlenmiştir. Covid-19 salgınının etkin olduğu süreçte alınan tedbirlerin camideki konfor şartlarının, iç hava kalitesinin ve enerji tüketiminin iyileşmesini sağladığı tespit edilmiştir. Simülasyon çalışmaları, yerden ısıtma sisteminin, yatsı – sabah ve sabah – öğle namazları arasında kapatılmasının %30'a kadar yakıt tasarrufu sağladığını göstermiştir. Yaz aylarında ise klimaların deneysel koşullarda olduğu gibi cemaatin isteği doğrultusunda kullanımı, oluşturulan senaryolara göre daha düşük elektrik tüketimi ve CO2 salımı ile sonuçlanmıştır.

Özet (Çeviri)

The increasing number of intermittently used temples, such as mosques, should not be overlooked in terms of their energy consumption although the share of continuously occupied spaces such as homes, offices, and workplaces in energy consumption is high. In this thesis study, the existing thermal comfort, indoor air quality, and energy consumption of Hacı Hasan Sert Mosque, representing a typical medium-scale neighborhood mosque in Yalova/Turkey, were experimentally investigated under different climatic conditions and occupancy rates during Friday, Eid, Tarawih, and regular daily prayers. Furthermore, scenarios incorporating HVAC system usage strategies aimed at achieving the current comfort conditions with reduced energy consumption were formed and simulated. The study aimed to determine the most healthy and comfortable conditions in the mosque with less energy consumption depending on the HVAC system's operational strategy and occupancy rates. Experimental investigations revealed that the increase in the number of congregants and the duration of mosque usage had positive effects on thermal comfort during winter months but negative effects during summer months. The indoor CO2 concentration increased up to 3500 ppm when the windows were closed during high occupancy. The lowest and highest indoor PM concentrations were observed after morning and night prayers, respectively. Therefore, it was determined that the most appropriate time for carpet sweeping was after the morning prayer. It was found that the measures taken during the Covid-19 pandemic period improved the comfort conditions, indoor air quality, and energy consumption in the mosque. Simulation studies demonstrated that turning off the underfloor heating system between night - morning prayers and between morning - noon prayers resulted in up to 30% fuel savings. In summer months, the use of air conditioning units for cooling according to the congregation' preferences, as per the formed scenarios, led to lower electricity consumption and CO2 emissions compared to experimental conditions.

Benzer Tezler

  1. Kubbeli yapıların yaz şartlarında iç ortamlarının ısıl analizi

    Thermal analysis of the internal environments in summer conditions of domed structures

    VEDAT ÇIPLAK

    Yüksek Lisans

    Türkçe

    Türkçe

    2019

    EnerjiHarran Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    PROF. DR. REFET KARADAĞ

  2. Kubbe örtülü camilerde iç mekan hava kalitesi için uygun açıklık tasarımına yönelik bir yöntem önerisi

    A suggestion of methodology toward designing of optimal aperture for the indoor air quality in domed mosques

    AYŞE ŞEYMA ÇOBAN

    Doktora

    Türkçe

    Türkçe

    2025

    MimarlıkGazi Üniversitesi

    Mimarlık Ana Bilim Dalı

    PROF. DR. İDİL AYÇAM

  3. Camilerin ısıl konfor ve enerji tüketimi açısından değerlendirilmesi için bir yöntem: İstanbul örneği

    A method for assessment of mosques in terms of thermal comfort and energy consumption: Istanbul as a case

    AHMET BİRCAN ATMACA

    Doktora

    Türkçe

    Türkçe

    2025

    MimarlıkYıldız Teknik Üniversitesi

    Mimarlık Ana Bilim Dalı

    PROF. DR. GÜLAY ZORER GEDİK

  4. Thermal comfort analysis of historical mosques. case study: The Ulu Mosque, Manisa, Turkey

    Tarihi camilerde ısıl konfor analizi. alan çalışması: Ulu cami, Manisa,Türkiye

    YUSUF DİLER

    Yüksek Lisans

    İngilizce

    İngilizce

    2019

    Enerjiİzmir Yüksek Teknoloji Enstitüsü

    Enerji Mühendisliği (enerji ve Güç Sistemleri) Ana Bilim Dalı

    PROF. DR. GÜLDEN GÖKÇEN AKKURT

    DR. ÖĞR. ÜYESİ CİHAN TURHAN

  5. Adaptive thermal comfort analysis of historic mosques: The case study of Salepcioglu Mosque, Izmir, Turkey

    Tarihi camilerin uyarlanır ısıl konfor analizi: Salepçioğlu Camisi alan çalışması, İzmir, Türkiye

    KHALED S M BUGHRARA

    Yüksek Lisans

    İngilizce

    İngilizce

    2016

    Enerjiİzmir Yüksek Teknoloji Enstitüsü

    Enerji Mühendisliği Ana Bilim Dalı

    DR. ZEYNEP DURMUŞ ARSAN

    PROF. DR. GÜLDEN GÖKÇEN AKKURT