Geri Dön

Term gebelerde umblikal coiling ındex,fetal serebral ve umblical arter doppler parametreleri ile umblikal ven kan gazı ve IMA değerleri arasındaki ilişkisinin araştırılması

Research of the relevance between umbilical coiling index, fetal cerebral and umblical artery doppler parameters, umblical vein blood gas and IMA values in term pregnants

  1. Tez No: 854493
  2. Yazar: ZEYNEP BEGÜM ÇELİK
  3. Danışmanlar: DOÇ. DR. GÜLSEREN DİNÇ
  4. Tez Türü: Tıpta Uzmanlık
  5. Konular: Kadın Hastalıkları ve Doğum, Obstetrics and Gynecology
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2024
  8. Dil: Türkçe
  9. Üniversite: Karadeniz Teknik Üniversitesi
  10. Enstitü: Tıp Fakültesi
  11. Ana Bilim Dalı: Kadın Hastalıkları ve Doğum Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 63

Özet

Amaç: Çalışmamızın amacı yenidoğanlarda oksidatif stresin bir göstergesi olarak da sayılabilecek İskemi Modifiye Albumin değeri, fetal iyilik halinin ilk belirteçlerinden olan umblikal ven kan gazı değerleri ve antenatal olarak ölçülebilecek değerler olan umblikal coiling indeks, umblikal ve orta serebral arter Doppler parametreleri ile arasında anlamlı bir ilişki olup olmadığının araştırılmasıdır. Gereç ve yöntem: Araştırma kapsamında Kadın Hastalıkları ve Doğum Anabilim Dalı polikliniğine gebe izlemi amacıyla başvuran ve yatışı yapılarak doğumu gerçekleştirilen, 37 hafta ve üzeri (term) gebeliği olan, risk faktörü sayılabilecek ek tanısı bulunmayan 65 gebeye doğum öncesi ultrason ile bakılarak umblikal coiling indeks, umblikal ve orta serebral arter Doppler parametreleri kaydedildi. Doğum sırasında umblikal venden alınan kan gazı ve serum örnekleri biyokimya laboratuvarına gönderildi ve kan gazı değerleri ile IMA (İskemi Modifiye Albumin) çalışılarak kaydedildi. Gebelerin yaşı, gravida ve parite sayısı, doğum haftası, yenidoğanların doğum kilosu, 5. Dakika APGAR skoru, yenidoğan yoğun bakım ünitesinde takip edilip edilmediği ve cinsiyetleri kaydedildi. Elde edilen veriler IBM SPSS 11.5 istatistik programı kullanılarak değerlendirildi. Bulgular: Umblikal kord coiling indeks ölçümlerinde en düşük ölçülen değer 0,210 coil/cm, en yüksek ölçülen değer 0,471 coil/cm, ortalama coiling indeks değeri 0,337 olarak ölçüldü. Umblikal ve orta serebral arter Doppler parametreleri referans değerlerin dışında izlenmedi. Coiling indeks ile umblikal ven kan gazı değerleri, IMA değerleri veya umblikal ve orta serebral arter Doppler indeksleri ile gebelik yaşı, gebelik haftası, 5. Dakika Apgar skoru arasında anlamlı bir korelasyon ilişkisi saptanmadı. Umblikal arter S/D oranı ile yenidoğan doğum ağırlığı arasında negatif yönde korelasyon (p

Özet (Çeviri)

Purpose: The aim of our study is to determine whether there is a significant relationship between the Ischemia Modified Albumin value, which can also be considered as an indicator of oxidative stress in newborns, the umbilical vein blood gas value, which is one of the first indicators of fetal well-being, and the umbilical coiling index, umbilical and middle cerebral artery Doppler parameters, which are values that can be measured antenatally. Material and method: Within the scope of the research, 65 pregnant women who applied to the Department of Obstetrics and Gynecology for pregnancy follow-up and were hospitalized and delivered, who had a pregnancy of 37 weeks or more (term) and who did not have an additional diagnosis that could be considered a risk factor, were examined with prenatal ultrasound and umbilical coiling index, umbilical and middle cerebral artery Doppler parameters were recorded. Blood gas and serum samples taken from the umbilical vein during birth were sent to the biochemistry laboratory and blood gas values and IMA (Ischemia Modified Albumin) were studied and recorded. Age, gravida and parity number of pregnant women, week of birth, birth weight of newborns, 5th minute APGAR score, whether they were followed in the neonatal intensive care unit and gender were recorded. Obtained data were evaluated using IBM SPSS 11.5 statistical program. Results: In umbilical cord coiling index measurements, the lowest measured value was 0.210 coil/cm, the highest measured value was 0.471 coil/cm, and the average coiling index value was 0.337. Umbilical and middle cerebral artery Doppler parameters were not observed differently from the reference values. No significant correlation was detected between the coiling index and umbilical vein blood gas values, IMA values, or umbilical and middle cerebral artery Doppler indices and gestational age, gestational week, or 5th minute Apgar score. There was a negative correlation between umbilical artery S/D ratio and newborn birth weight (p

Benzer Tezler

  1. Term gebelerde intrapartum fetal zayıflığın öngörüsünde serebroplasental oranın yeri

    The importance of cerebroplacental ratio in predicting intrapartum fetal compromise at term

    BURCU UÇAR

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2020

    Kadın Hastalıkları ve DoğumEge Üniversitesi

    Kadın Hastalıkları ve Doğum Ana Bilim Dalı

    PROF. DR. M. SAİT YÜCEBİLGİN

  2. İntrauterin hepatik ve portal venöz sistemin renkli doppler ultrasonografi ile değerlendirilmesi

    Colour doppler ultrasonographic evaluation of the intrauterine hepatic and portal venous system

    MEHMET AKİF SARICA

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2010

    Kadın Hastalıkları ve DoğumGaziantep Üniversitesi

    Radyoloji Ana Bilim Dalı

    PROF. DR. REŞAT KERVANCIOĞLU

  3. Sezaryen operasyonlarında genel ve rejyonel anestezi uygulamalarımızın maternal ve neonatal etkilerinin değerlendirilmesi

    Evaluation of the maternal and neonatal effects of OUR general and regional anesthesia practices in cesarean section operations

    DERYA KAPLAN TOSUN

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2023

    Anestezi ve ReanimasyonAkdeniz Üniversitesi

    Anesteziyoloji ve Reanimasyon Ana Bilim Dalı

    PROF. DR. NURTEN KAYACAN

  4. Obez gebelerde maternal ve umbilikal kord homosistein düzeylerinin incelenmesi

    The assessment of maternal and umbilical cord homocystein levels in obese pregnant women

    BAŞAK KAYA

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2012

    Kadın Hastalıkları ve DoğumSağlık Bakanlığı

    Kadın Hastalıkları ve Doğum Ana Bilim Dalı

    UZMAN SERDAR KAYA

  5. Sezaryen ile doğum yapan term ve preterm gebelerde maternal ve umbilikal kord HE 4 düzeyleri

    He4 levels in term and preterm pregnant patients whogave birth with ceserian section

    HANDE ESRA KOCA

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2019

    Kadın Hastalıkları ve DoğumSağlık Bilimleri Üniversitesi

    Kadın Hastalıkları ve Doğum Ana Bilim Dalı

    PROF. DR. TUNCAY KÜÇÜKÖZKAN