Comparison of accuracy and reproducibility of Cephio and Webceph with conventional method

Cephio ve Webceph'in doğruluğunun ve tekrarlanabilirliğinin geleneksel yöntemle karşılaştırılması

  1. Tez No: 861966
  2. Yazar: THAER AL KHUDARI
  3. Danışmanlar: PROF. DR. MUSTAFA HALUK İŞERİ
  4. Tez Türü: Yüksek Lisans
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Sefalometri, Webceph, Cephio, geleneksel yöntem, güvenilirlik, yeniden üretilebilirlik, Cephalometry, Webceph, Cephio, reliability, reproducibility
  7. Yıl: 2024
  8. Dil: İngilizce
  9. Üniversite: İstanbul Yeni Yüzyıl Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Ortodonti Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Amaç: Bu çalışma,“Webceph”ve“Cephio”web uygulamalarından alınan sefalometrik ölçümlerin doğruluğunu ve tekrarlanabilirliğini, geleneksel yöntemle karşılaştırarak değerlendirmektedir. Ortodontik tedavide vazgeçilmez olan sefalometrik analiz, teknolojiyle birlikte gelişerek bilgisayar destekli yöntemlerin ortaya çıkmasına neden olmuştur. Bu araştırmanın amaç, yapay zeka destekli, kullanıcı dostu web uygulamalarının sağlık hizmetlerinde karmaşık veya manuel tekniklerin yerini etkili bir şekilde alıp alamayacağını araştırmaktır. Gereç ve Yöntemler: Toplam 40 hastada, 23 iskeletsel ve dişsel parametre tanımlanmıştır. WebCeph, Cephio ve konvansiyonel yöntem kullanılarak sefalometrik radyografiler üzerinde toplam 27 ölçüm yapılmıştır. Webceph, Cephio uygulamalarından ve konvansiyonel yöntemden elde edilen ölçümler aynı operatör tarafından 4 hafta arayla iki kez uygulanmıştır. Güvenilirlik, Pearson korelasyon katsayısı kullanılarak değerlendirilmiş ve yöntemler arasındaki farklılıklar (tekrarlanabilirlik) p<0,05 olarak belirlenen anlamlılık düzeyi ile ANOVA ve eşleştirilmiş t-testleri ile hesaplanmıştır. Bulgular: Pearson korelasyon katsayısı, çok yüksek düzeyde bir güvenirliğe işaret eden güçlü bir korelasyon göstermiştir (tüm ölçümler için r2 > 0,84). Anova'ya göre üç ölçüm yöntemi arasında 18 istatistiksel fark vardır (SN, N S Ar, N S Ba, S Ar, SNA, Co A, ANS PNS /SN, SNB, Co Gn, Ar Go, Ar Go Gn, N S Go Me, ANS PNS /Go Gn, ANS PNS/Go Me, Wits, Nazolabial açı, U dudaktan E çizgisine, L dudaktan E çizgisine) (p<0,05). Geleneksel yöntem ile Webceph arasındaki eşleştirilmiş t-testine göre 9 istatistiksel fark vardır (SNA, Co A, Co Gn, Ar Go, N S/Go Me, Ans Pns/Go Gn, ANS PNS/Go Me, U1'den NA'ya (derece), L dudaktan E çizgisine). Geleneksel yöntem ile Cephio arasında yapılan eşleştirilmiş t-testine göre 8 istatistiksel fark mevcuttur (SN, S Ar, Co A, Co Gn, Ar Go Gn, ANS PNS/Go Me, Wits, Nazolabial açı). Sonuç: Yarı otomatik yöntemler birçok açıdan geleneksel yöntemlerle yüksek güvenilirlik ve tutarlılık göstermiş, bazı parametrelerde önemli farklılıklar görülmüştür. Bazı ölçümler geleneksel yönteme göre farklılık gösterebileceğinden yorumlanırken dikkatli olmalıdır. Ancak, bu yapay zeka araçlarının verimliliği ve veri yönetimi yetenekleri klinik uygulamada önemli avantajlar sunmaktadır. Kullanıcı dostu olma ve maliyet etkinliğinin olumlu katkısı, bu alanda artan popülerliğe önemli ölçüde katkıda bulunmaktadır.

Özet (Çeviri)

Purpose: This study assesses the accuracy and reproducibility of cephalometric measurements from“Webceph”and“Cephio”web apps, comparing them to the conventional method. Essential in orthodontic treatment, cephalometric analysis has evolved with technology, leading to computer-aided methods. This research explores whether AI-driven, user-friendly web applications can effectively replace complex or manual technique in healthcare. Material and Methods: A total of 40 patients, 23 skeletal and dental parameters were defined and a total of 27 measurements were measured on cephalometric radiographs using WebCeph, Cephio, and the conventional method. Measurements obtained from Webceph, Cephio applications and conventional method were made by the same operator twice with an interval of 4 weeks. Reliability was assessed using Pearson's correlation coefficient, and variations between methods (reproducibility) were calculated by the ANOVA and paired t- tests, with a significance level set at p<0.05. Results: The Pearson correlation coefficient demonstrated a strong correlation, indicating a very high level of reliability (r2 > 0.84 for all measurements). According to Anova there were 18 statistical differences between the three measurement methods (SN, N S Ar, N S Ba, S Ar, SNA, Co A, ANS PNS /SN, SNB, Co Gn, Ar Go, Ar Go Gn, N S Go Me, ANS PNS /Go Gn, ANS PNS/Go Me, Wits, Nasolabial angle, U lip to E line, L lip to E line). According to the paired t-test between the conventional method and Webceph there were 9 statistical differences (SNA, Co A, Co Gn, Ar Go, N S/Go Me, Ans Pns/Go Gn, ANS PNS/Go Me, U1 to NA(deg), L lip to E line). According to the paired t-test between the conventional method and Cephio there were 8 statistical differences (SN, S Ar, Co A, Co Gn, Ar Go Gn, ANS PNS/Go Me, Wits, Nasolabial angle). Conclusion: The semi-automated method demonstrated high reliability and consistency with conventional method in many aspects, certain parameters exhibited significant differences. Care should be taken when interpreting certain measurements, as they may vary from conventional method. The efficiency and data management capabilities of these AI tools, however, present significant advantages in clinical practice. This combination of user- friendliness and cost-effectiveness significantly contributes to their growing popularity in the field.

Benzer Tezler

  1. Sayısal ortodontik model analizinde kullanılan farklı yazılımların tekrarlanabilirlik, güvenilirlik ve hassasiyet açılarından karşılaştırılması

    Comparison of accuracy, reliability, and reproducibility of 3 different digital model softwares

    AYDAN COŞKUN ATEŞ

    Doktora

    Türkçe

    Türkçe

    2011

    Marmara Üniversitesi

    Ortodonti Ana Bilim Dalı

    Yükleniyor...

  2. Glokom hastalarında HRT 3 cihazında MRA ve GPS programlarının tanısal değerlerinin karşılaştırılması

    Comparison of the diagnostic accuracy of MRA and GPS programs on HRT 3 device in glaucoma patients

    MAHMUT OĞUZ ULUSOY

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2012

    Celal Bayar Üniversitesi

    Göz Hastalıkları Ana Bilim Dalı

    Yükleniyor...

  3. Farklı dijital oklüzal analiz cihazları ile elde edilen interoklüzal kayıtların doğruluk ve tekrarlanabilirliğinin karşılaştırılması

    Comparison of precision and reproducibility of interocclusal recordings obtained with different digital occlusal analyzers

    BÜŞRA UĞURGELEN

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2022

    Marmara Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    Yükleniyor...

  4. 3 boyutlu dijital modeller üzerinde yapılan ölçümlerin güvenilirliğinin ve tekrarlanabilirliğinin değerlendirilmesi

    Evaluation of the reliability and reproducibility of measurements on 3 dimensional digital models

    NARİN ÖZTÜRK

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2020

    Ankara Üniversitesi

    Ortodonti Ana Bilim Dalı

    Yükleniyor...

  5. Sigara dumanına aktif ve pasif maruz kalan kişilerde tırnak örneğinde nikotin ve kotinin seviyelerinin karşılaştırılması

    Comparison of nicotine and cotine levels in nail samples of people active and passive exposed to cigarette smoke

    BURCU DURAN

    Yüksek Lisans

    Türkçe

    Türkçe

    2024

    İstanbul Üniversitesi-Cerrahpaşa

    Fen Bilimleri Ana Bilim Dalı

    Yükleniyor...