Geri Dön

Optik mikrodamla algılama sistemi tasarımı ve proses performansının deneysel analizi

Optical microdrop detection system design and experimental analysis of process performance

  1. Tez No: 895946
  2. Yazar: HALİD CEYLAN
  3. Danışmanlar: PROF. DR. KADRİ SÜLEYMAN YİĞİT
  4. Tez Türü: Yüksek Lisans
  5. Konular: Mekatronik Mühendisliği, Tıbbi Biyoloji, Makine Mühendisliği, Mechatronics Engineering, Medical Biology, Mechanical Engineering
  6. Anahtar Kelimeler: Debi, Fiziksel optik, Optik sensörler, Sıvı damlası modelleri, İnfüzyonlar-intravenöz, Flow, Physical measurements, Optical sensors, Liquid drop models, Infusions-intravenous
  7. Yıl: 2024
  8. Dil: Türkçe
  9. Üniversite: Kocaeli Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Makine Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Sıvı İntravenöz İnfüzyon (IV) uygulamalarında, yer çekimi etkisi ile çalışan infüzyon sistemleri ve bu sistemlerin kontrol sistemleri giderek artan bir popülariteye sahiptir. Bu tez çalışması ile, IV uygulamaları kontrol sistemleri için damla sayma tekniği kullanılarak yeni bir debi ve hacim algılama sistemi tasarımı gerçekleştirilmiştir. Bu amaçla tez çalışmasında öncelikli olarak mikrodamla oluşumu incelenmiş, mikrodamlaların hacim ve debiye etkileri analiz edilmiştir. Yapılan analizlere göre algılama sistemi hata oranları ve bu hataların sebep-sonuç ilişkileri tanımlanmıştır. Bu tanımlamalara bağlı olarak algılama sisteminin parametreleri ortaya çıkarılmıştır. Deneysel çalışma aşamasında ise, oluşturulan yeni algılama sistemi ile farklı akışkan hızlarında deneyler gerçekleştirilmiştir. Deney sonuçları, akışkan debi ve hacim verileri üzerinden detaylı olarak tartışılmıştır.

Özet (Çeviri)

In Liquid Intravenous Infusion (IV) applications, infusion systems working with the effect of gravity and the control systems of these systems are increasingly popular. With this thesis study, a new flow and volume detection system design was carried out using the drop counting technique for IV application control systems. For this purpose, in the thesis study, microdrop formation was primarily examined and the effects of microdrops on volume and flow rate were analyzed. According to the analysis, detection system error rates and cause-effect relationships of these errors were defined. Based on these definitions, the parameters of the perception system were revealed. In the experimental study phase, experiments were carried out at different fluid velocities with the new detection system created. The experimental results are discussed in detail based on fluid flow and volume data.

Benzer Tezler

  1. Ağızlık açma mekanizmalarının tasarımı

    Başlık çevirisi yok

    RECEP EREN

    Yüksek Lisans

    Türkçe

    Türkçe

    1987

    Uludağ Üniversitesi

    Tekstil Mühendisliği Ana Bilim Dalı

    Yükleniyor...

  2. İnce taneli sementasyon çeliklerinde sıcak şekil verme ve ısıl işleminin ostenit tane büyüklüğüne etkisi

    Başlık çevirisi yok

    MERAL ŞANLI

    Yüksek Lisans

    Türkçe

    Türkçe

    1987

    Uludağ Üniversitesi

    Fizik Ana Bilim Dalı

    Yükleniyor...

  3. Akaryakıtla çalışan endüstriyel tav fırınlarında yanma, sıcaklık ve basıncın optimum kontrolu

    Optimum control of combustion temperature and pressure in industrial tempering furnaces working with fuel-oil

    MEHMET EROĞLU

    Yüksek Lisans

    Türkçe

    Türkçe

    1987

    Gazi Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    Yükleniyor...

  4. Tedaviye cevap vermeyen diyabetik makula ödeminde vitreoskizisin rolü

    The role of vitreoschisis in diabetic macular edema refractory to treatment

    MAKBULE BERNA ÖTÜK YAŞAR

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2008

    İstanbul Üniversitesi

    Göz Hastalıkları Ana Bilim Dalı

    Yükleniyor...