Geri Dön

Zirkonya materyallerinin farklı yüzey bitirme işlemleri sonrası renk değişiminin karşılaştırılması

Comparison of color change of zirconia materials after different surface finishing processes

  1. Tez No: 944161
  2. Yazar: SERAP FALCI
  3. Danışmanlar: PROF. DR. SELİM ERKUT
  4. Tez Türü: Doktora
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Translüsent monolitik zirkonya, Polisaj, Glaze, Renklenme, Translucent monolithic zirconia, Polishing, Glaze, Staining
  7. Yıl: 2025
  8. Dil: Türkçe
  9. Üniversite: Başkent Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
  12. Bilim Dalı: Protetik Diş Tedavisi Bilim Dalı
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Bu in vitro çalışmanın amacı, farklı translüsensiye ve farklı kalınlığa sahip zirkonya materyallerinin yüzey bitirme işlemleri sonrası yüzey özelliklerinin incelenmesi ve termal döngü ile yüzey renklendirici bir ajana maruz bırakılması sonucu yüzey renklenmelerinin karşılaştırılmasıdır. Bu tez çalışmasında Vita (VITA Zahnfabrik, Almanya) markasına ait, sırayla 4Y-TZP ve 5Y-TZP içeriklerine sahip süper translüsent ve ekstra translüsent monolitik zirkonya diskler frezelenerek, yarısı 0,8 mm diğer yarısı 2 mm kalınlıkta olan toplam 128 adet blok hazırlanmış ve sinterlenmiştir. Belirlenen çalışma grupları doğrultusunda, GrSinter grubundaki örneklere (n=32) sinterizasyon sonrasında herhangi bir yüzey bitirme ve polisaj işlemi uygulanmamıştır. GrFırın grubundaki örnekler (n=32) sinterizasyondan sonra 3 defa tekrarlanan fırınlama işlemine tabi tutulmuştur. GrGlaze grubundaki örneklere (n=32) elmas frezle yüzey aşındırması yapıldıktan sonra glaze uygulanmıştır. GrPolisaj grubundaki örnekler (n=32) yüzey aşındırmasından sonra polisaj kitiyle polisajlanmıştır. Ardından tüm örneklere 5000 döngüde termal yaşlandırma uygulanmıştır ve başlangıç (T0) renk ölçümleri Vita Easyshade (VITA Zahnfabrik, Bad Sackingen ve Almanya) spektrofotometre ile yapılmıştır. 60 gün boyunca 37°C etüvde hazır kahve solüsyonu içerisinde bekletilen örneklerin renk ölçümü 1. hafta (T1), 2. hafta (T2), 1. ay (T3) ve 2. ayda (T4) tekrarlanmıştır. Tüm örneklerin yüzey pürüzlülüğü Perthometer M2 profilometre cihazı (The Universal Standard Instrument Mahr GmbH ve Almanya) ile ölçülmüştür. Bu çalışmada 1 ve 3,5 arasındaki renk değişim (ΔE) değerleri klinik olarak kabul edilebilir olarak değerlendirilmiştir. Çalışmamızda neredeyse tüm örneklerde ΔE>3,5 olarak bulunmuştur. Yalnızca GrGlaze XT 2 mm grubundaki örneklerdeki renklenme diğer tüm gruplara göre klinik olarak kabul edilebilir olarak bulunmuştur. Zirkonya kalınlığının Ra değerini etkilemediği (p>0,05) ancak, ΔE değerini etkilediği sonucuna varılmıştır (p<0,001). İnce örneklerde ΔE değeri, kalın örneklere kıyasla daha yüksek bulunmuştur. Ra değeri en yüksek GrSinter ve GrFırın gruplarında bulunurken, en düşük GrGlaze grubunda bulunmuştur. Zirkonyanın translüsensi farkı Ra ve ΔE değerlerinde istatistiksel olarak anlamlı bir fark yaratmamıştır (p>0,05). Anterior bölge restorasyonlarında kullanılan translüsent monolitik zirkonyanın renk stabilitesinin korunması estetik açıdan önemli olduğu için bu in vitro çalışmanın sonuçlarının da günümüzde anterior bölgede sıkça tercih edilen ve yeni geliştirilen translüsent monolitik zirkonyaların, renklenme potansiyeline bağlı olarak klinik seçimine yön verme konusunda bilgi vereceği düşünülmektedir. Bu çalışma Başkent Üniversitesi Tıp ve Sağlık Bilimleri Araştırma Kurulu tarafından onaylanmış (Proje no: D-KA24/08) ve Başkent Üniversitesi Araştırma Fonunca desteklenmiştir.

Özet (Çeviri)

The aim of this in vitro study is to investigate the surface properties of zirconia materials with different translucency and different thickness after surface finishing processes, and to compare the surface coloration after thermal cycling and exposure to a surface coloring agent. In this thesis study, monolithic zirconia discs manufactured by Vita (VITA Zahnfabrik, Germany) with 4Y-TZP (super translucent) and 5Y-TZP (extra translucent) compositions were used. The discs were milled using a CAD/CAM system to obtain a total of 128 specimens, with half of them prepared at 0.8 mm and the other half at 2 mm thickness. All specimens were subsequently sintered according to the manufacturer's instructions. Based on the experimental design, no surface finishing or polishing procedures were applied to GrSinter group (n=32). GrFırın group (n=32) specimens were subjected to a repeated firing cycle performed three times following sintering. After surface abrasion with a diamond bur, a glaze layer was applied to GrGlaze group (n=32). GrPolisaj group (n=32) specimens underwent polishing using a polishing kit after surface abrasion. Following surface treatments, all specimens were subjected to thermocycling for 5000 cycles. Initial color measurements (T0) were performed using Vita Easyshade (VITA Zahnfabrik, Bad Sackingen and Germany) spectrophotometer. Specimens were then immersed in a instant coffee solution at 37°C in an incubator, and color measurements were repeated at the 1st week (T1), 2nd week (T2), 1st month (T3), and 2nd month (T4). Surface roughness (Ra) of all specimens was measured using a profilometer device (Perthometer M2, The Universal Standard Instrument, Mahr GmbH and Germany). In this study, color change (ΔE) values between 1 and 3.5 were considered clinically acceptable. In our study, ΔE>3.5 was found in almost all samples. Only the coloration in the samples in the GrGlaze XT 2 mm group was considered clinically acceptable compared to all other groups. It was concluded that the zirconia thickness did not affect the Ra value (p>0.05), but affected the ΔE value (p<0.001). The ΔE value was found to be higher in thin samples compared to thick samples. The highest Ra value was found in the GrSinter and GrFırın groups, while the lowest was found in the GrGlaze group. The difference in the translucency of zirconia did not create a statistically significant difference in the Ra and ΔE values (p<0.05). Since preserving the color stability of translucent monolithic zirconia used in anterior region restorations is important from an aesthetic point of view, it is thought that the results of this in vitro study will provide information on guiding the clinical selection of newly developed translucent monolithic zirconia, which is frequently preferred in the anterior region today, depending on the coloration potential. This study was approved by Baskent University Institutional Review Board (Project no: D-KA24/08) and supported by Baskent University Research Fund.

Benzer Tezler

  1. Zirkonya esaslı seramik kaplamanın fiziksel ve kimyasal özelliklerinin değiştirilmesi

    Changing physical and chemical properties of zirconia based ceramic coating

    İSMET ÇEVİK

    Doktora

    Türkçe

    Türkçe

    1990

    İstanbul Teknik Üniversitesi

    Yükleniyor...

  2. Mullit-Zirkonya seramik kompozitlerinin reaksiyon sinterlemesi yöntemi ile elde edilmesi ve stransiyum oksit katkısısnın etkisi

    Başlık çevirisi yok

    SEHER KINIKOĞLU

    Doktora

    Türkçe

    Türkçe

    1993

    Yıldız Teknik Üniversitesi

    Metalurji Mühendisliği Ana Bilim Dalı

    Yükleniyor...

  3. Plazma sprey kaplamalarda bazı malzeme parametrelerinin bağlanma mukavemetine etkileri

    Başlık çevirisi yok

    MURAT DEMİRCİ

    Yüksek Lisans

    Türkçe

    Türkçe

    1994

    Marmara Üniversitesi

    Yükleniyor...

  4. A Study for the properties of zirconiq toughened alumina via statistical methods

    İstatistik yöntemlerle zirkonya toklandırılmış alumina özellikleri konusunda bir çalışma

    NUR ÖZKAN

    Yüksek Lisans

    İngilizce

    İngilizce

    1994

    Orta Doğu Teknik Üniversitesi

    Metalurji Mühendisliği Ana Bilim Dalı

    Yükleniyor...