Duvardan radyant soğutmalı deplasmanlı havalandırma ile desteklenmiş bir mahalin ısıl konforunun deneysel incelenmesi
Experimental investigation of thermal comfort in a space with radiant cooling panels embedded in the wall and supported by displacement ventilation
- Tez No: 1002706
- Danışmanlar: PROF. DR. AHMET SELİM DALKILIÇ
- Tez Türü: Yüksek Lisans
- Konular: Makine Mühendisliği, Mechanical Engineering
- Anahtar Kelimeler: Belirtilmemiş.
- Yıl: 2026
- Dil: Türkçe
- Üniversite: Yıldız Teknik Üniversitesi
- Enstitü: Fen Bilimleri Enstitüsü
- Ana Bilim Dalı: Makine Mühendisliği Ana Bilim Dalı
- Bilim Dalı: Isı Proses Bilim Dalı
- Sayfa Sayısı: Belirtilmemiş.
Özet
Termal konfor, bireylerin içinde bulundukları ortam koşullarını çeşitli açılardan değerlendirdiklerinde memnuniyet duydukları durumu ifade eder. Özellikle kapalı ortamlarda çalışan bireylerin verimliliği ve sağlığı açısından büyük önem taşıyan termal konfor, bina tasarımı, havalandırma sistemleri ve enerji verimliliği bakımından kritik bir rol oynar. Bu çalışmada, radyant soğutmalı bir duvarın deplasmanlı havalandırma ile desteklendiği bir düzenek deneysel olarak incelenmiştir. Bu yaklaşımın, deney odasındaki çeşitli yüzeylerdeki ve odanın orta noktasındaki dikey sıcaklık dağılımlarını ve farklarını nasıl etkilediği değerlendirilerek, radyant duvara gönderilen su sıcaklıkları ve üfleme kanalı hava hızları ölçümleri ile termal konfor koşulları ortaya konulmuştur. Bu kapsamda, bir odanın bir duvarının radyant soğutma sistemi ile soğutulduğu, zemin seviyesiden difüzörler ile deplasmanlı havalandırma yapıldığı ve farklı senaryoların etkilerinin incelendiği durumlar deneyler ile değerlendirilmiştir. Soğuk iç duvar yüzey sıcaklığı yoğuşma olmaması maksadıyla 14–16 °C aralığında seçilmiştir. Hava giriş sıcaklığı sabit tutulurken, difüzör öncesi üfleme kanalı içerisindeki hava hızları 0, 0,25 ve 0,5 m/s olarak belirlenmiştir. Radyant panelleri besleyen suyun giriş sıcaklıkları ise 12.9, 13,9 ve 14,9 °C olmak üzere üç farklı değer olarak belirlenmiştir. Çeşitli sıcaklık dağılımları ve farkları, Testo 400 termal konfor cihazından elde edilen PMV-PPD indeksleri ile değerlendirilmiş; sonuçlar ASHRAE 55 standardında tanımlanan termal konfor kriterleriyle karşılaştırılmıştır. Bulgulara göre, 0,5 m/s besleme hızında iç ortamın daha homojen bir dağılım sergilediği görülmüştür. Senaryolarda, oturur pozisyonda baş seviyesi–ayak bileği seviyesi sıcaklık farkı 0,4–1,2 °C aralığında kalarak 3 °C sınırının belirgin biçimde altında kalmıştır. Bu koşullarda 0,5 m/s besleme hızında ölçülen tavan–taban sıcaklık farkı 0,25 m/s besleme hızında 1,1–1,7°C aralığındayken 0,5–1,1°C aralığına gerilemiştir. Buna paralel olarak PMV değerleri −0,3 ile +0,3 aralığında kalarak ±0,5 sınırını aşmamıştır. PPD değerleri ise %5,0–%6,9 aralığında gerçekleşerek %10 sınırının altında kalmıştır. Sonuç olarak, mevcut çalışma kapsamında uygulanan havalandırma sisteminin iç mekan konforunun iyileştirilmesi için uygulanabilir bir yaklaşım olduğu değerlendirilmiştir.
Özet (Çeviri)
Thermal comfort refers to the condition in which individuals feel satisfied when they evaluate the environmental conditions they are exposed to from various perspectives. Thermal comfort, which is of great importance for the productivity and health of individuals working in indoor environments, plays a critical role in building design, ventilation systems, and energy efficiency. In this study, an experimental setup in which a radiantly cooled wall is supported by displacement ventilation was investigated. By evaluating how this approach affects the vertical temperature distributions and differences on various surfaces in the test room and at the room center, thermal comfort conditions were revealed through measurements of the water temperatures supplied to the radiant wall and the air velocities in the supply duct. Within this scope, cases in which one wall of a room was cooled by a radiant cooling system, displacement ventilation was provided via diffusers at floor level, and the effects of different scenarios were examined were evaluated experimentally. The cold interior wall surface temperature was selected in the range of 14–16 °C in order to avoid condensation. While the inlet air temperature was kept constant, the air velocities in the supply duct upstream of the diffusers were set to 0.0, 0.25, and 0.5 m/s. The inlet temperatures of the water supplying the radiant panels were determined as three different values: 12.9, 13.9, and 14.9 °C. Various temperature distributions and differences were evaluated using the PMV–PPD indices obtained from the Testo 400 thermal comfort instrument, and the results were compared with the thermal comfort criteria defined in ASHRAE 55. According to the findings, a more homogeneous indoor distribution was observed at the supply velocity of 0.5 m/s. Across the scenarios, the temperature difference between head level and ankle level in the seated posture remained within 0.4–1.2 °C and was well below the 3 °C limit. Under these conditions, the measured ceiling–floor temperature difference decreased from 1.1–1.7 °C at 0.25 m/s to 0.5–1.1 °C at 0.5 m/s. In parallel, PMV values remained between −0.3 and +0.3 and did not exceed the ±0.5 limit. PPD values ranged from 5.0% to 6.9% and remained below the 10% limit. As a result, the ventilation system applied within the scope of the present study was considered to be an applicable approach for improving indoor comfort.
Benzer Tezler
- Radyant soğutmalı duvar ve slot difüzörlü havalandırmalı bir mahalde ısıl konforun incelenmesi
Examination of thermal comfort in a radiant cooled wall and slot diffuser ventilated room
MELEK ÇALIŞKAN TEMİZ
Doktora
Türkçe
2026
Makine MühendisliğiYıldız Teknik ÜniversitesiMakine Mühendisliği Ana Bilim Dalı
PROF. DR. AHMET SELİM DALKILIÇ
DOÇ. DR. MUHAMMET CAMCI
- Duvardan ısıtma ve soğutmalı toprak kaynaklı ısı pompasının performansının incelenmesi
Performance analysis of the ground source heat pump with wall heating and cooling
ASLIHAN BAŞKAL
Yüksek Lisans
Türkçe
2011
Makine MühendisliğiYıldız Teknik ÜniversitesiMakine Mühendisliği Ana Bilim Dalı
PROF. DR. OLCAY KINCAY
- Yüzeyden ısıtma sistemli modüler hibrit duvar panelindeki alüminyum folyonun ölçülerinin belirlenmesi
The estimation of aluminium foil dimensions in the modular hybrid wall heating panel system
MEVLÜT GÜRSEL ÇETİN
Yüksek Lisans
Türkçe
2016
EnerjiYıldız Teknik ÜniversitesiMakine Mühendisliği Ana Bilim Dalı
DOÇ. DR. ŞEVKET ÖZGÜR ATAYILMAZ
DR. ZAFER GEMİCİ
- Yerden soğutma sisteminin deneysel olarak incelenmesi için ashrae 138 standardına uygun bir test odasının tasarımı, kurulumu ve performans testleri
Design, installation and performance tests of a test room according to ashrae 138 for experimental investigation of underfloor radiant cooling system
GÜLTEKİN ŞAHİN
Yüksek Lisans
Türkçe
2019
Makine MühendisliğiGazi ÜniversitesiMakine Mühendisliği Ana Bilim Dalı
PROF. DR. ABUZER ÖZSUNAR
- Evaluating the LCA of two buildings with close embodied energy which have different functions
Farklı işlevlere sahip olan iki binanın üç tür duvar kullanarak yaşam döngüsünün değerlendirilmesi
POOYA PAKMEHR
Yüksek Lisans
İngilizce
2014
Mimarlıkİstanbul Teknik ÜniversitesiMimarlık Ana Bilim Dalı
DOÇ. DR. MUSTAFA ERKAN KARAGÜLER