Geri Dön

İmplant üstü dijital ölçülerde kullanılan farklı tarama gövdesi tasarımlarının ölçü hassasiyetine etkisinin değerlendirilmesi

The effect of different scan body designs used in digital implant impression on accuracy

  1. Tez No: 1012735
  2. Yazar: ECEM KAHYA
  3. Danışmanlar: PROF. DR. FATMA GÜLBAHAR IŞIK ÖZKOL
  4. Tez Türü: Doktora
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Ağız-dişsiz, Dental implantlar, Dental kalıp alma teknikleri, Dental tarayıcılar, Dijital tarama, Mouth-edentulous, Dental implants, Dental impression technics, Dental scanners, Digital scanning
  7. Yıl: 2026
  8. Dil: Türkçe
  9. Üniversite: İstanbul Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
  12. Bilim Dalı: Protetik Diş Tedavisi Bilim Dalı
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Amaç: Çoklu implant vakalarında ağız içi tarayıcıyla alınan tam ark dijital ölçülerde, tarama mesafesinin artmasıyla birlikte kümülatif hata birikimi riski yükselmektedir. Tarama gövdesi geometrisinin bu hata birikimi üzerindeki etkisi konusunda henüz bir kesin kanı bulunmamaktadır. Bu çalışmanın amacı, farklı geometrik özelliklere sahip özel tarama gövdesi tasarımları ile splintleme yönteminin tam ark dijital ölçülerde açısal ve lineer hassasiyete etkisini değerlendirmektir. Gereç ve Yöntem: Altı paralel implant içeren alt ve üst çene modelleri kullanıldı. Kısa silindirik, uzun silindirik, kısa yamuk ve uzun yamuk geometrilerinde özel tarama gövdeleri CAD/CAM yöntemiyle üretildi. Standart ve splintlenmiş tarama gövdesi gruplarıyla birlikte toplam altı tarama grubu oluşturuldu. Her gruptan ağız içi tarayıcıyla dijital ölçüler alındı; açısal ve lineer sapma değerleri masaüstü tarayıcıyla elde edilen referans model üzerinde Geomagic Control X yazılımıyla hesaplandı. Anlamlılık p<0,05 düzeyinde değerlendirildi. Bulgular: Tarama grupları arasında açısal sapma bakımından anlamlı farklılık saptandı (p=0,011); en düşük ortanca değer splintleme grubunda (0,40°), en yüksek değer kısa silindirik grupta (0,76°) elde edildi. Çene ile tarama grubu etkileşimi anlamlı bulundu (p<0,001). Uzun tasarımlar kısa tasarımlara kıyasla daha düşük açısal sapma gösterdi (p=0,026); geometrik şekil tek başına etkili olmazken (p=0,503), çene ile etkileşime girdiğinde anlamlı farklılık oluşturdu (p=0,013). Lineer sapma açısından hem tarama grupları (p=0,038) hem de çeneler (p=0,014) arasında anlamlı farklılık saptandı. Sonuç: Tarama gövdesi geometrik tasarımı, tam ark dijital ölçülerde açısal ve lineer sapma üzerinde anlamlı etkiye sahiptir. Uzun tasarımlar açısal doğrulukta kısa tasarımlara üstünlük sağlamış, splintleme grubu en düşük sapma değerlerini sergilemiştir. Çene tipi ile tasarım arasındaki etkileşim, grupların farklı çenelerde farklı performans gösterdiğini ortaya koymuştur.

Özet (Çeviri)

Aim: In full-arch digital impressions of multiple implant cases, the risk of cumulative error accumulation increases with scanning distance. There is no consensus regarding the effect of scan body geometry on this error. This study aimed to evaluate the effect of custom scan body designs with different geometric properties and the splinting technique on angular and linear accuracy of full-arch digital impressions. Materials and Methods: Maxillary and mandibular models with six parallel implants were used. Custom scan bodies were fabricated by CAD/CAM in four geometries: short cylindrical, long cylindrical, short trapezoidal, and long trapezoidal. Including standard and splinted scan body groups, six scanning groups were formed. Digital impressions were obtained using an intraoral scanner; angular and linear deviations were calculated on a desktop scanner-acquired reference model using Geomagic Control X software. Significance was set at p<0.05. Results: A significant difference was found among groups regarding angular deviation (p=0.011); the lowest median was in the splinting group (0.40°), the highest in the short cylindrical group (0.76°). Long designs showed significantly lower angular deviation (p=0.026); geometric shape alone was not significant (p=0.503) but produced a significant difference when interacting with jaw (p=0.013). For linear deviation, significant differences were found both among groups (p=0.038) and between jaws (p=0.014). Conclusion: Scan body geometric design significantly affects both angular and linear deviation in full-arch digital impressions. Long designs outperformed short designs in angular accuracy, and the splinting group exhibited the lowest deviation values. The jaw–design interaction demonstrated that groups performed differently across jaws.

Benzer Tezler

  1. Dijital ölçü aşamasında kullanılan titanyum ve peek tarama gövde materyallerinin yer değiştirmeye bağlı hassasiyetinin değerlendirilmesi

    Evaluation of displacement precision of titanium and peek scan body materials used in digital impression

    EMRE DİKER

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2021

    Ankara Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    Yükleniyor...

  2. Kobaylarda splenik ototransplantasyon ve postsplenektomi sepsisi

    Başlık çevirisi yok

    S.ÇAĞATAY ÇİFTER

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1987

    Gazi Üniversitesi

    Genel Cerrahi Ana Bilim Dalı

    Yükleniyor...

  3. Saleplerin tohumla üretilmeleri

    Başlık çevirisi yok

    NURGÜL SÜBEROĞLU

    Yüksek Lisans

    Türkçe

    Türkçe

    1987

    Ege Üniversitesi

    Peyzaj Mimarlığı Ana Bilim Dalı

    Yükleniyor...

  4. Filtre edilebilme sayısı ile filtrasyon optimum dozunun araştırılması

    Başlık çevirisi yok

    HULUSİ ÇOKADAR

    Doktora

    Türkçe

    Türkçe

    1984

    İstanbul Teknik Üniversitesi

    Yükleniyor...