Farklı lateral osteotomi dizaynı ile yapılan sagittal split ramus osteotomisindeki fiksasyon tekniklerinin stabiliteye etkisi : In vitro çalışma
The effect of fixation techniques on stability in sagittal split ramus osteotomy performed with different lateral osteotomy design : In vitro study
- Tez No: 1024638
- Danışmanlar: DR. ÖĞR. ÜYESİ TUBA DEVELİ
- Tez Türü: Doktora
- Konular: Diş Hekimliği, Dentistry
- Anahtar Kelimeler: Lateral osteotomi, sagittal split ramus osteotomisi, fiksasyon, Lateral osteotomy, sagittal split ramus osteotomy, fixation
- Yıl: 2026
- Dil: Türkçe
- Üniversite: İstanbul Medipol Üniversitesi
- Enstitü: Sağlık Bilimleri Enstitüsü
- Ana Bilim Dalı: Ağız, Diş ve Çene Cerrahisi Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
Çalışmanın amacı farklı lateral osteotomi dizaynları ile gerçekleştirilen sagittal split ramus osteotomisi modellerinde iki farklı fiksasyon tekniğinin biyomekanik stabilite üzerine etkisini değerlendirmektir. Bu amaçla klasik lateral osteotomi dizaynı ve minimal invaziv lateral osteotomi dizaynı; tek miniplak ve dört monokortikal vida fiksasyonu ile üç bikortikal vida fiksasyonu kullanılarak karşılaştırılmıştır. Çalışmada benzer yaş ve gelişim özelliklerine sahip koyunlardan elde edilen 20 adet mandibula kullanılmıştır. Mandibulalar yumuşak dokularından temizlendikten sonra orta hattan ayrılarak toplam 40 hemimandibula elde edilmiştir. Örnekler her grupta 10 hemimandibula olacak şekilde rastgele dört gruba ayrılmıştır. Grup 1'de klasik lateral osteotomi dizaynı sonrası tek miniplak ve dört monokortikal vida ile fiksasyon, Grup 2'de klasik lateral osteotomi dizaynı sonrası üç bikortikal vida ile fiksasyon, Grup 3'te minimal invaziv lateral osteotomi dizaynı sonrası tek miniplak ve dört monokortikal vida ile fiksasyon, Grup 4'te ise minimal invaziv lateral osteotomi dizaynı sonrası üç bikortikal vida ile fiksasyon uygulanmıştır. Osteotomi sonrası distal segmentler tüm gruplarda standart olarak 5 mm anterior ve 5 mm vertikal yönde, saat yönünün tersine rotasyon oluşturacak şekilde konumlandırılmıştır. Fiksasyon işlemlerinin ardından hemimandibula modelleri Shimadzu AGS-X üniversal test cihazında değerlendirilmiştir. Molar dişler bölgesinden 1 mm/dak hızla doğrusal kuvvet uygulanmış ve 20, 60, 100, 120, 150 ve 200 N kuvvet düzeylerinde oluşan yer değiştirme miktarları milimetre cinsinden kaydedilmiştir. Çalışmada kuvvet düzeyi arttıkça tüm gruplarda yer değiştirme miktarlarının arttığı gözlenmiştir. Tüm kuvvet düzeylerinde en yüksek ortalama yer değiştirme değerleri Grup 1'de, en düşük ortalama yer değiştirme değerleri ise Grup 4'te elde edilmiştir. Grup 1'de ortalama yer değiştirme değerleri 20, 60, 100, 120, 150 ve 200 N kuvvet düzeylerinde sırasıyla 0,37 mm, 0,76 mm, 1,45 mm, 1,99 mm, 2,47 mm ve 2,88 mm olarak bulunmuştur. Grup 4'te ise aynı kuvvet düzeylerinde ortalama yer değiştirme değerleri sırasıyla 0,02 mm, 0,15 mm, 0,32 mm, 0,41 mm, 0,53 mm ve 0,69 mm olarak saptanmıştır. Kruskal-Wallis testi sonucunda tüm kuvvet düzeylerinde 1 gruplar arasında istatistiksel olarak anlamlı fark bulunmuştur. Bonferroni düzeltmeli ikili karşılaştırmalarda 20 N ve 60 N kuvvet düzeylerinde Grup 4'teki yer değiştirme değerlerinin Grup 1 ve Grup 2'ye göre anlamlı düzeyde düşük olduğu belirlenmiştir. 100, 120, 150 ve 200 N kuvvet düzeylerinde ise Grup 4'ün Grup 1'e göre anlamlı düzeyde daha düşük yer değiştirme gösterdiği saptanmıştır. Çalışmanın bulguları BSSRO modellerinde lateral osteotomi dizaynı ve fiksasyon yönteminin biyomekanik stabilite üzerinde birlikte etkili olduğunu göstermektedir. Minimal invaziv lateral osteotomi dizaynı, klasik lateral osteotomi dizaynına göre daha düşük deplasman değerleri göstermiştir. Ayrıca üç bikortikal vida fiksasyonu, tek miniplak ve monokortikal vida fiksasyonuna kıyasla daha yüksek mekanik stabilite sağlamıştır. Çalışmanın deneysel koşulları altında en yüksek biyomekanik stabilite, minimal invaziv lateral osteotomi dizaynı ile üç bikortikal vida fiksasyonunun birlikte kullanıldığı grupta elde edilmiştir. Bu nedenle minimal invaziv lateral osteotomi dizaynının uygun fiksasyon yöntemiyle birlikte kullanıldığında klasik yaklaşıma biyomekanik açıdan alternatif oluşturabileceği düşünülmektedir.
Özet (Çeviri)
The aim of this study was to evaluate the effect of two different fixation techniques on biomechanical stability in sagittal split ramus osteotomy models performed with different lateral osteotomy designs. For this purpose, the conventional lateral osteotomy design and the minimally invasive lateral osteotomy design were compared using fixation with one miniplate and four monocortical screws, and fixation with three bicortical screws. In this study, 20 mandibles obtained from sheep with similar age and developmental characteristics were used. After the mandibles were cleaned of soft tissues, they were divided at the midline to obtain a total of 40 hemimandibles. The specimens were randomly divided into four groups, with 10 hemimandibles in each group. In Group 1, fixation was performed with one miniplate and four monocortical screws after conventional lateral osteotomy design. In Group 2, fixation was performed with three bicortical screws after conventional lateral osteotomy design. In Group 3, fixation was performed with one miniplate and four monocortical screws after minimally invasive lateral osteotomy design. In Group 4, fixation was performed with three bicortical screws after minimally invasive lateral osteotomy design. After osteotomy, the distal segments were positioned in a standardized manner in all groups, 5 mm anteriorly and 5 mm vertically, creating counterclockwise rotation. Following fixation, the hemimandible models were evaluated using a Shimadzu AGS-X universal testing machine. A linear force was applied from the molar region at a speed of 1 mm/min, and the displacement values occurring at force levels of 20, 60, 100, 120, 150, and 200 N were recorded in millimeters. In the study, displacement values increased in all groups as the force level increased. The highest mean displacement values at all force levels were obtained in Group 1, whereas the lowest mean displacement values were obtained in Group 4. In Group 1, the mean displacement values at 20, 60, 100, 120, 150, and 200 N were 0.37 mm, 0.76 mm, 1.45 mm, 1.99 mm, 2.47 mm, and 2.88 mm, respectively. In Group 4, the mean displacement values at the same force levels were 0.02 mm, 0.15 mm, 0.32 3 mm, 0.41 mm, 0.53 mm, and 0.69 mm, respectively. The Kruskal-Wallis test revealed statistically significant differences among the groups at all force levels. In Bonferroni adjusted pairwise comparisons, the displacement values in Group 4 were found to be significantly lower than those in Groups 1 and 2 at force levels of 20 N and 60 N. At force levels of 100, 120, 150, and 200 N, Group 4 showed significantly lower displacement values than Group 1. The findings of this study indicate that lateral osteotomy design and fixation method jointly affect biomechanical stability in BSSRO models. The minimally invasive lateral osteotomy design demonstrated lower displacement values compared with the conventional lateral osteotomy design. In addition, fixation with three bicortical screws provided greater mechanical stability than fixation with one miniplate and monocortical screws. Under the experimental conditions of this study, the highest biomechanical stability was achieved in the group in which minimally invasive lateral osteotomy design was combined with fixation using three bicortical screws. Therefore, it is considered that the minimally invasive lateral osteotomy design may represent a biomechanically viable alternative to the conventional approach when used with an appropriate fixation method.
Benzer Tezler
- Bazı esterlerin kinetik incelenmesi ve termodinamik parametrelerin belirlenmesi
Kinetic study and detesmination of thermodnamic parameters of some esters
İBRAHİM TAŞ
- İzmir'de bazı yolların kapatılarak yaya bölgeleri oluşturma da kent peyzajını geliştirme açısından yeniden planlanması üzerinde araştırmalar
Başlık çevirisi yok
BAHAR TÜRKYILMAZ
- Testosteron dihidrotestosteron ve östrojenin benign prostat hiperplazisindeki etyolojik rolleri
The roles of testosterone, dihydrotestosterone and estradiole on the etiology of benign prostatic hyperplasia
HALUK TOKUÇOĞLU
- Süt formüllerinin tüketim uygulamaları ve süt formüllerinin C vitamini içeriği ile pH değerleri
Başlık çevirisi yok
GÖNÜL VAROL