Geri Dön

Bentonit katkılı ortopedik alçı kompozitlerinin yapısal, mekanik ve radyografik özelliklerinin deneysel olarak incelenmesi

Experimental investigation of structural, mechanical and radiographic properties of bentonite-reinforced orthopedic gypsum composites

  1. Tez No: 1026104
  2. Yazar: MELİKE DURSUN
  3. Danışmanlar: DOÇ. DR. HAYRETTİN EROĞLU
  4. Tez Türü: Yüksek Lisans
  5. Konular: Kimya, Chemistry
  6. Anahtar Kelimeler: Mekanik dayanım, Mikroyapı, Yapısal özellikler, Mechanical strength, Microstructure, Structural properties
  7. Yıl: 2026
  8. Dil: Türkçe
  9. Üniversite: Erzurum Teknik Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Kimya Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Bu çalışmada, kırık tespit uygulamalarında kullanılmak üzere geliştirilen bentonit katkılı ortopedik alçı kompozitlerinin mekanik, mikroyapısal, termal ve radyasyon geçirgenlik özellikleri deneysel olarak incelenmiştir. Kompozit numuneler, kalsiyum sülfat esaslı ortopedik alçı matrisi içerisine ağırlıkça %1, %2,5, %5 ve %10 oranlarında bentonit ilave edilerek hazırlanmıştır. Numunelerin basma dayanımı, priz süresi, termal iletkenlik ve radyasyon geçirgenlik davranışları değerlendirilmiş; mikroyapısal karakterizasyon SEM, EDS, FTIR ve XRD analizleri ile gerçekleştirilmiştir. Sonuçlar, bentonit ilavesinin alçı matrisinin fiziksel ve yapısal özelliklerini önemli ölçüde etkilediğini göstermiştir. Basma dayanımı sonuçları, düşük ve orta katkı oranlarında mekanik performansın büyük ölçüde korunduğunu, yüksek katkı oranlarında ise artan gözeneklilik ve parçacık aglomerasyonu nedeniyle dayanımın azaldığını ortaya koymuştur. Priz süresi analizleri, bentonitin hidratasyon sürecini hızlandırarak ilk ve son priz sürelerini kısalttığını göstermiştir. Radyasyon geçirgenlik analizlerinde bentonitin özellikle düşük enerji bölgesinde lineer ve kütlesel zayıflatma katsayılarını etkilediği belirlenmiş, %2,5 bentonit içeren numune radyografik görüntüleme açısından en dengeli geçirgenlik davranışını sergilemiştir. Termal iletkenlik sonuçlarında en düşük değer %5 bentonit katkılı numunede elde edilirken, SEM analizleri düşük ve orta katkı oranlarında daha kompakt ve homojen bir mikroyapı oluştuğunu göstermiştir. Genel olarak, bentonit katkılı ortopedik alçı kompozitlerinin geleneksel alçı sistemlerini geliştirme potansiyeline sahip olduğu belirlenmiştir.

Özet (Çeviri)

In this study, the mechanical, microstructural, thermal, and radiation attenuation properties of bentonite-reinforced orthopedic plaster composites developed for fracture immobilization applications were experimentally investigated. Composite specimens were prepared by incorporating bentonite into a calcium sulfate-based orthopedic plaster matrix at weight fractions of 1%, 2.5%, 5%, and 10%. Compressive strength, setting time, thermal conductivity, and radiation attenuation properties were evaluated, while microstructural characterization was performed using SEM, EDS, FTIR, and XRD analyses. The results demonstrated that bentonite incorporation significantly influenced the physical and structural properties of the plaster matrix. Compressive strength was largely maintained at low and moderate bentonite contents but decreased at higher addition levels due to increased porosity and particle agglomeration. Setting time analyses indicated that bentonite accelerated the hydration process, resulting in shorter initial and final setting times. Radiation attenuation analyses showed that bentonite affected the linear and mass attenuation coefficients, particularly in the low-energy region, while the specimen containing 2.5 wt.% bentonite exhibited the most balanced radiographic performance. The lowest thermal conductivity was obtained for the specimen containing 5 wt.% bentonite, and SEM observations revealed a more compact and homogeneous microstructure at low and moderate bentonite contents. Overall, bentonite-reinforced orthopedic plaster composites demonstrated considerable potential for improving the performance of conventional orthopedic plaster systems.

Benzer Tezler

  1. Bentonit katkılı siltli numunelerin üç eksenli cihazda hacimsel davranışı

    Volumetric behavior of bentonite added silty samples in a triaxial device

    CEMRE MUHİKANCİ

    Yüksek Lisans

    Türkçe

    Türkçe

    2025

    Sakarya Üniversitesi

    İnşaat Mühendisliği Ana Bilim Dalı

    Yükleniyor...

  2. Bentonit katkılı siltli numunelerin kesme kutusu davranışı

    Shear test behavior of silty samples with bentonite additive

    İLKNUR BOZARSLAN

    Yüksek Lisans

    Türkçe

    Türkçe

    2025

    Sakarya Üniversitesi

    İnşaat Mühendisliği Ana Bilim Dalı

    Yükleniyor...

  3. Bentonit katkılı siltli numunelerin konsolidasyonlu-drenajsız üç eksenli (CU) davranışı

    Consolidated-undrained triaxial (CU) behavior of bentonite-admixed silty samples

    YUNUS CANTÜRK

    Yüksek Lisans

    Türkçe

    Türkçe

    2025

    Sakarya Üniversitesi

    İnşaat Mühendisliği Ana Bilim Dalı

    Yükleniyor...

  4. Polivinil alkol katkılı Na-bentonit kompozitlerin yapısal, termal ve dielektrik özelliklerinin incelenmesi

    Investigation of structural, thermal and dielectric properties of polyvinyl alcohol added Na-bentonite composites

    YEŞİM AKAR

    Yüksek Lisans

    Türkçe

    Türkçe

    2019

    Kocaeli Üniversitesi

    Fizik Ana Bilim Dalı

    Yükleniyor...

  5. Polimetilmetakrilat katkılı ham bentonit ve Na- bentonitin yapısal ve dielektrik özelliklerinin incelemesi

    Investigation of structural and dielectric properties of raw bentonite and Na-bentonite with polymethylmetacrylate additives

    EYLEM TATOĞLU

    Yüksek Lisans

    Türkçe

    Türkçe

    2019

    Kocaeli Üniversitesi

    Fizik Ana Bilim Dalı

    Yükleniyor...