Geri Dön

Femur lateral korteks devamlılığı olmayan intertrokanterik kırıklarda sefalomedüller çivileme ile sefalomedüller çivi ve trokanterik plak kombinasyonu uygulamasının biyomekanik karşılaştırılması

Biomechanical comparison of cephalomedullary nailing and cephalomedullary nail combined with a trochanteric plate in intertrochanteric fractures without lateral femoral cortex continuity

  1. Tez No: 1028649
  2. Yazar: BURAK MERT
  3. Danışmanlar: DR. ÖĞR. ÜYESİ ÖZKAN ÖZTÜRK
  4. Tez Türü: Tıpta Uzmanlık
  5. Konular: Ortopedi ve Travmatoloji, Orthopedics and Traumatology
  6. Anahtar Kelimeler: Biyomekanik Test, Çevrimsel Yükleme, İntertrokanterik Femur Kırığı, Lateral Femoral Duvar, Proksimal Femoral Çivi, Trokanterik Grip Plak, Biomechanical Testing, Cyclic Loading, Intertrochanteric Femoral Fracture, Lateral Femoral Wall, Proximal Femoral Nail, Trochanteric Grip Plate
  7. Yıl: 2026
  8. Dil: Türkçe
  9. Üniversite: Sağlık Bakanlığı
  10. Enstitü: Sabuncuoğlu Şerefeddin Eğitim ve Araştırma Hastanesi
  11. Ana Bilim Dalı: Ortopedi ve Travmatoloji Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Bu çalışmanın amacı, lateral femoral duvar ve posteromedial desteğin olmadığı instabil intertrokanterik femur kırıklarında yalnız proksimal femoral çivi (PFN) ile oluşturulan konstrüksiyon ile PFN'ye trokanterik grip plak eklenen konstrüksiyonun biyomekanik davranışlarını karşılaştırmaktır. Deneysel biyomekanik laboratuvar çalışmasında 20 standart sol kompozit femur kullanıldı. Tüm modellerde lateral femoral duvar ve trokanter minörü içeren posteromedial desteğin ayrıldığı AO/OTA 31-A3.3 instabil intertrokanterik kırık oluşturuldu. Numuneler sadece PFN ve PFN + plak gruplarına ayrıldı. Her iki grupta 10 × 240 mm, 125° kısa PFN; 10 × 100 mm tek sefalik lag vidası ve tek 5,0 mm distal kilitleme vidası kullanıldı. Kombine tespit grubunda ek olarak yedi delikli trokanterik plak, iki adet 5,0 mm proksimal kilitli vida ve üç adet Dall–Miles tipi serklaj kablosu uygulandı. Her gruptaki beş konstrüksiyon 2 mm/dk hızla makroskopik yapısal kırılmaya kadar aksiyel basma deneyine, diğer beş konstrüksiyon ise 70–700 N yük aralığında, 2 Hz frekansta 200.000 çevrimlik aksiyel yükleme deneyine alındı. Statik deneylerde maksimum aksiyel taşıma yükü ve maksimum yükteki aktüatör deplasmanı değerlendirildi. Çevrimsel deneylerde run-out durumu ve 200. ile 199.800. çevrimler arasında biriken ek aksiyel deplasman incelendi. Ortalama maksimum aksiyel taşıma yükü sadece PFN yapılan grupta 2,723 ± 0,204 kN, PFN + plak grubunda 3,27 ± 0,203 kN olarak bulundu. PFN + plak grubundaki değer yaklaşık %20,2 daha yüksek olup gruplar arasındaki fark istatistiksel olarak anlamlıydı (p = 0,002). Maksimum yükteki aktüatör deplasmanı sadece PFN grubunda 27,766 ± 1,71 mm, PFN + plak grubunda 35,500 ± 3,985 mm idi (p = 0,009). Biriken ortalama ek aksiyel deplasman sadece PFN grubunda 6,41 mm, PFN + plak grubunda 1,29 mm olarak hesaplandı. PFN + plak grubundaki birikmiş deplasman betimsel olarak yaklaşık %79,9 daha düşüktü. İncelenen AO/OTA 31-A3.3 sentetik kırık modeli ve deney koşulları altında PFN'ye trokanterik plak–vida–kablo konstrüksiyonu eklenmesi, maksimum aksiyel taşıma kapasitesini artırmış ve tekrarlayan yükler altında progresif aksiyel oturmayı sınırlandırmıştır.

Özet (Çeviri)

The aim of this study was to compare the biomechanical behavior of a proximal femoral nail (PFN) alone with PFN augmented by a trochanteric plate in an unstable intertrochanteric fracture model lacking lateral femoral wall and posteromedial support. Twenty standardized left composite femora were used. An AO/OTA 31-A3.3 unstable intertrochanteric fracture was created in all specimens by separating the lateral femoral wall and posteromedial support, including the lesser trochanter. Specimens were allocated to PFN-only and PFN + plate groups. In both groups, an 10 × 240 mm, 125° short PFN, a 10 × 100 mm lag screw, and a 5.0 mm distal locking screw were used. In the combined group, a seven-hole trochanteric plate, two 5.0 mm proximal locking screws, and three Dall–Miles-type cerclage cables were added. Five constructs per group underwent axial compression at 2 mm/min until macroscopic structural failure, while the remaining five underwent cyclic axial loading between 70 and 700 N at 2 Hz for 200,000 cycles. Maximum axial load and actuator displacement at maximum load were assessed during static testing. In cyclic testing, run-out status and accumulated additional axial displacement between cycles 200 and 199,800 were evaluated. Mean maximum axial load was 2.723 ± 0.204 kN in the PFN-only group and 3.27 ± 0.203 kN in the PFN + plate group, representing an approximately 20,2% increase with plate augmentation (p = 0.002). Actuator displacement at maximum load was 27.766 ± 1.71 mm and 35.500 ± 3.985 mm, respectively (p = 0.009). Mean accumulated additional axial displacement was 6.41 mm in the PFN-only group and 1.29 mm in the PFN + plate group, corresponding to an approximately 79.9% descriptive reduction. Under the tested conditions, addition of a trochanteric plate–screw–cable construct to PFN fixation increased maximum axial load-bearing capacity and limited progressive axial settling under repetitive loading.

Benzer Tezler

  1. Femur intertrokanterik kırık nedeniyle proksimal femur çivileme yapılan hastaların cerrahi sonrası kalça abdüksiyon gücünün değerlendirilmesi

    DUE to intertrochanteric fracture of the femurpatients with proximal femur nailing evaluation of hip abusion strength after surgery

    HAKAN ARLI

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2021

    Sağlık Bilimleri Üniversitesi

    Ortopedi ve Travmatoloji Ana Bilim Dalı

    Yükleniyor...

  2. Femur intertrokanterik kırıklarda proksimal femur çivisi uygulamalarında lag vida yerleşim bölgesine ait dansitenin fiksasyon üzerine etkisi

    The effect of bone density at the lag screw insertion site on fixation in proximal femoral nailing for intertrochanteric femur fractures

    ÖMER FARUK ÇELİK

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2025

    Sağlık Bilimleri Üniversitesi

    Ortopedi ve Travmatoloji Ana Bilim Dalı

    Yükleniyor...

  3. Menteşeli diz protezlerinde (modüler tümör rezeksiyon tipi) değişik femoral stem uzunluklarının femur üzerindeki stress etkileri in-vitro biomekanik çalışma

    The effect of different femoral stem lengths on the femoral bone with hinge type (modular tumor resection) knee prosthesis

    EYAD SKAIK

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2004

    Dokuz Eylül Üniversitesi

    Ortopedi ve Travmatoloji Ana Bilim Dalı

    Yükleniyor...

  4. Menteşeli diz protezlerinde (modüler tümör rezeksiyon tipi) değişik femoral stem uzunluklarının femur üzerindeki stress etkileri

    The effect of different femoral stem length on the femoral bone with hinge type (modular tumor resection) knee prothesis

    EYAD SKAİK

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2004

    Dokuz Eylül Üniversitesi

    Ortopedi ve Travmatoloji Ana Bilim Dalı

    Yükleniyor...

  5. Varus gonartrozunda medı̇al açık kama osteotomı̇sı̇ tedavı̇lerı̇mı̇z ve geç dönem sonuçlarımız

    Medial open wedge osteotomy treatments in varus gonarthrosis and long term results

    ÖMER ÖZEL

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2009

    Sağlık Bakanlığı

    Ortopedi ve Travmatoloji Ana Bilim Dalı

    Yükleniyor...