Geri Dön

Ccd–merrill crowe proses entegrasyonunda filtrasyon performansı ve operasyonel parametrelerin optimizasyonunun incelemesi

Investigation of filtration performance and optimisation of operational parameters in ccd–merrill crowe process integration

  1. Tez No: 1029780
  2. Yazar: SEMİH ERZENOĞLU
  3. Danışmanlar: DOÇ. DR. HÜSEYİN BAŞTÜRKCÜ
  4. Tez Türü: Yüksek Lisans
  5. Konular: Maden Mühendisliği ve Madencilik, Mining Engineering and Mining
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2026
  8. Dil: Türkçe
  9. Üniversite: İstanbul Teknik Üniversitesi
  10. Enstitü: Lisansüstü Eğitim Enstitüsü
  11. Ana Bilim Dalı: Cevher Hazırlama Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Cevher Hazırlama Mühendisliği Bilim Dalı
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Altın ve gümüş kazanımında yaygın olarak kullanılan Merrill–Crowe prosesi, özellikle berrak solüsyon kalitesi ve filtrasyon performansına yüksek derecede bağlı çalışan bir proses olup işletme sürekliliğinin sağlanmasında kritik rol oynamaktadır. Filtrasyon performansındaki bozulmalar, sementasyon verimini, işletme sürekliliğini ve nihai metal kazanımını doğrudan etkileyebilmektedir. Bu nedenle Merrill–Crowe ünitesi öncesinde gerçekleştirilen katı-sıvı ayırma işlemlerinin etkinliği ve filtrasyon koşullarının kontrol altında tutulması, proses performansının sürdürülebilirliği açısından büyük önem taşımaktadır. Bu tez çalışmasında, Özbekistan Almalık bölgesinde faaliyet gösteren ve Merrill–Crowe prosesi ile işletilen altın zenginleştirme tesisinde devreye alma ve erken işletme döneminde gözlemlenen filtrasyon problemlerinin kök nedenlerinin belirlenmesi ve gerçekleştirilen operasyonel iyileştirmelerin laboratuvar ortamında doğrulanması amaçlanmıştır. Çalışma kapsamında Counter Current Decantation (CCD) ve Merrill–Crowe prosesleri arasındaki etkileşim değerlendirilmiş; filtrasyon performansını etkileyebileceği değerlendirilen operasyonel parametreler sistematik olarak incelenmiştir. Bu doğrultuda toplam 40 adet laboratuvar ölçekli deney gerçekleştirilmiş; pH, bulanıklık (turbidity), kaplama (precoat) uygulaması, flokülant, koagülant, solüsyonun dinlendirilmesi, silis tutunması ve metalik çinko dozajı gibi değişkenlerin filtrasyon davranışı üzerindeki etkileri araştırılmıştır. Deneysel çalışmalar sırasında filtrasyon süresi, diferansiyel basınç değişimi, bulanıklık, çözünmüş silis miktarı ve filtrat kalitesi birlikte değerlendirilmiş; elde edilen laboratuvar sonuçları saha gözlemleri ile karşılaştırılarak yorumlanmıştır. Elde edilen sonuçlar, filtrasyon performansı üzerinde en belirleyici parametrenin bulanıklık kontrolü olduğunu göstermiş; ikinci derecede etkili parametreler olarak flokülant uygulaması ve pH kontrolü öne çıkmıştır. Özellikle CCD operasyonunun kararlılığı ve uygun flokülasyon koşullarında düşük bulanıklık seviyelerinin korunmasının, Merrill–Crowe filtrasyonunun sürdürülebilir şekilde işletilmesinde kritik olduğu belirlenmiştir. pH değişiminin çözeltideki silis davranışı üzerinde etkili olduğu, yüksek pH koşullarında çözünmüş silisin faz değişimine eğilim gösterebildiği ve bunun filtrasyon davranışını dolaylı olarak etkileyebileceği değerlendirilmiştir. Diğer parametrelerin ise düşük ölçüde etkili olmakla birlikte sistem performansını tek başına belirleyen faktörler olmadığı görülmüştür. Çalışma sonucunda saha gözlemleri ile laboratuvar bulguları arasında yüksek uyum elde edilmiştir. Filtrasyon problemlerinin azaltılmasına yönelik uygulanabilir bir işletme yaklaşımı koşulları ortaya konularak tesis optimizasyonuna yönelik bulgular elde edilmiştir.

Özet (Çeviri)

Merrill–Crowe process is one of the most widely applied hydrometallurgical methods for the recovery of gold and silver from cyanide leach solutions, particularly in operations where high-grade pregnant solutions are produced. The efficiency of this process largely depends on the clarity of the pregnant solution before cementation. Suspended solids, colloidal materials, and fine particles remaining in the solution may significantly reduce filtration efficiency, shorten filter operating life, increase differential pressure, and adversely affect the cementation stage. Consequently, maintaining an efficient solid–liquid separation system and ensuring stable filtration performance are essential not only for precious metal recovery but also for maintaining continuous and reliable plant operation. In industrial gold processing plants, the Counter Current Decantation (CCD) circuit and the Merrill–Crowe process operate as consecutive stages. Although these units perform different functions, their operational performances are closely interconnected. Variations in CCD overflow quality directly influence the filtration stage preceding the Merrill–Crowe unit. Therefore, understanding the interaction between these two process units and identifying the operational parameters governing filtration performance are of considerable importance for improving plant efficiency. Despite the widespread industrial application of the Merrill–Crowe process, studies focusing on the operational relationship between CCD performance and filtration behavior remain relatively limited. This study was carried out to contribute to this subject by combining field observations with laboratory-scale experimental investigations. The primary objective of this thesis was to determine the root causes of filtration problems observed during the commissioning and early operational stages of a gold processing plant operating with the Merrill–Crowe process in the Almalyk region of Uzbekistan. Another objective was to verify, under controlled laboratory conditions, the effectiveness of the operational improvements implemented in the plant. Throughout the study, the interaction between the Counter Current Decantation (CCD) circuit and the Merrill–Crowe filtration system was evaluated, and the operational parameters that could potentially influence filtration performance were systematically investigated. A comprehensive laboratory testing program consisting of 40 laboratory-scale experiments was designed to simulate actual plant operating conditions. Experimental studies focused on operational parameters including pH, turbidity, precoat application, flocculant dosage, coagulant application, solution settling, silica retention, and metallic zinc dosage. Each parameter was investigated individually in order to evaluate its influence on filtration behavior while minimizing the effects of other variables. Throughout the experimental program, filtration time, filtration rate, differential pressure, turbidity, dissolved silica concentration, filtrate quality, and filter cake behavior were carefully monitored and recorded. The laboratory findings were continuously compared with observations obtained from plant operation in order to evaluate the consistency and practical applicability of the results. The experimental results demonstrated that turbidity control was the most influential parameter affecting filtration performance. Lower turbidity values consistently resulted in shorter filtration times, lower differential pressure, improved filtrate quality, and more stable filter operation. These findings confirmed that maintaining low suspended solid concentrations before filtration is essential for achieving sustainable Merrill–Crowe operation. The study also showed that the stability of the CCD circuit and the optimization of flocculation conditions play a decisive role in controlling the turbidity level of the pregnant solution supplied to the filtration stage. Flocculant application was identified as another significant operational parameter. Laboratory observations indicated that both the dosage and preparation of the flocculant solution affected filtration performance. Proper dilution and dosage promoted effective particle aggregation and improved clarification efficiency, whereas excessive or improperly prepared flocculant solutions produced unfavorable filtration behavior by increasing filtration resistance. These findings highlighted the necessity of maintaining an appropriate balance between flocculant dosage and solution turbidity in order to maximize filtration efficiency. The influence of pH on filtration performance was also investigated in detail. Although moderate pH variations did not produce significant changes in filtration rate under normal operating conditions, higher pH values affected the behavior of dissolved silica present in the pregnant solution. Laboratory analyses suggested that increasing pH promoted the transformation of dissolved silica into colloidal or gel-like structures, particularly after a certain solution retention period. This phenomenon was associated with increased turbidity, higher filtration resistance, and gradual accumulation of silica-related deposits on the filter surface. While complete filter blockage was not observed during laboratory experiments, the results indicated that long-term operation under highly alkaline conditions could contribute to progressive filtration deterioration. Precoat material selection was evaluated by comparing different commercially available filter aid materials. The experiments demonstrated that cellulose-based precoat materials provided superior mechanical stability and more consistent filtration performance compared with alternative materials. Differences in cake stability, crack formation, permeability, and filtrate quality were clearly observed among the tested materials. These findings emphasize that appropriate precoat selection contributes not only to filtration efficiency but also to filter operational stability. The effects of coagulant application, solution settling, and metallic zinc dosage were also investigated. Solution settling significantly reduced turbidity through natural particle sedimentation and consequently improved filtration performance. Coagulant application produced varying results depending on the initial characteristics of the solution, indicating that its effectiveness depends on solution composition rather than dosage alone. In contrast, metallic zinc dosage within the investigated operating range showed no significant direct influence on filtration performance, suggesting that its primary role remains limited to the cementation process rather than filtration behavior. Comparison of laboratory observations with actual plant performance demonstrated a high degree of agreement between experimental findings and industrial operating conditions. The consistency of the results confirmed that the experimental methodology successfully represented the principal mechanisms affecting filtration performance in the Merrill–Crowe process. Furthermore, the study provided practical recommendations for optimizing filtration operation by controlling turbidity, maintaining appropriate flocculation conditions, selecting suitable precoat materials, and managing solution chemistry, particularly with respect to pH and dissolved silica behavior. Overall, this study presents an integrated evaluation of filtration performance within the CCD–Merrill–Crowe process by combining field experience with systematic laboratory investigations. The findings contribute to a better understanding of the operational factors governing filtration efficiency and provide practical guidance for reducing filtration-related problems in industrial precious metal recovery plants. The proposed operational approach is expected to support process optimization, improve operational reliability, and enhance the long-term sustainability of Merrill–Crowe filtration systems.

Benzer Tezler

  1. Televizyon teknolojisinde CCD chipli kameralar ve video yazımlama üniteleri

    CCD cameras and video recording units at television technology

    KORAY ERSOY

    Yüksek Lisans

    Türkçe

    Türkçe

    1999

    Ege Üniversitesi

    Radyo Televizyon Ana Bilim Dalı

    Yükleniyor...

  2. Optimum stüdyo tasarımı için CCD kameraların performans analizi

    The performance analysis of the CCD cameras for designig an optimum studio

    UFUK ÜMİT BÜYÜK

    Yüksek Lisans

    Türkçe

    Türkçe

    2000

    Karadeniz Teknik Üniversitesi

    Elektronik Mühendisliği Ana Bilim Dalı

    Yükleniyor...

  3. CCD teknolojisine dayalı olan yarıiletken foto-dedektörlü kızılötesi görüntü çeviricinin incelenmesi

    Başlık çevirisi yok

    MURAT AKPINAR

    Yüksek Lisans

    Türkçe

    Türkçe

    2001

    Gazi Üniversitesi

    Fizik Ana Bilim Dalı

    Yükleniyor...

  4. Samanyolu galaksisinin CCD-sloan fotometrisi ile incelenmesi

    CCD-sloan photometric investigation of the milky way galaxy

    SELÇUK BİLİR

    Doktora

    Türkçe

    Türkçe

    2002

    İstanbul Üniversitesi

    Astronomi ve Uzay Bilimleri Ana Bilim Dalı

    Yükleniyor...

  5. CCD photometry and time deries analysis of V2275 Cyg and RW UMi using data from the Tubitak national observatory

    Tubitak ulusal gözlemevi verilerini kullanarak V2275 Cyg ve RW UMi`nin CCD fotometrisi ve zaman serisi analizi

    MUSTAFA ARDA YILMAZ

    Yüksek Lisans

    İngilizce

    İngilizce

    2004

    Orta Doğu Teknik Üniversitesi

    Fizik Ana Bilim Dalı

    Yükleniyor...