İki farklı markaya ait implantların farklı değişkenler eşliğinde kemiğe yerleştirilmesi sırasında kemikte oluşturduğu sıcaklık değişimi ve stresin incelenmesi
Examination of the temperature change and stress created in the bone during the placement of implants of two different brands with different variables
- Tez No: 1030360
- Danışmanlar: PROF. DR. CENK FATİH ÇANAKÇI
- Tez Türü: Doktora
- Konular: Diş Hekimliği, Dentistry
- Anahtar Kelimeler: Dental implant, sıcaklık, stres, Dental implantlar, Diş hekimliği, Dental implant, stress, temperature, Dental implants, Dentistry
- Yıl: 2026
- Dil: Türkçe
- Üniversite: Atatürk Üniversitesi
- Enstitü: Sağlık Bilimleri Enstitüsü
- Ana Bilim Dalı: Periodontoloji Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
Amaç: Bu çalışmanın amacı, farklı implant sistemleri, implant çapları, yerleştirme derinlikleri, tork değerleri ve kemik modellerinin peri-implant kemikte oluşturduğu stres dağılımını ve implant yuvası preparasyonu sırasında farklı frezleme koşullarının kemikte meydana getirdiği sıcaklık değişimini değerlendirmektir. Materyal ve Metot: Sonlu elemanlar analizinde Evoss 3.5×10 mm, Evoss 4.8×10 mm ve Nucleoss 3.5×10 mm implant modelleri kullanıldı. Mandibular D2 ve maksiller D4 kemik modellerinde 4, 7 ve 10 mm yerleştirme derinlikleri ile 20 ve 40 Ncm tork ko-şulları değerlendirildi. Kortikal kemikte Von Mises, Maximum Principal ve Minimum Principal; trabeküler kemikte Maximum Principal ve Minimum Principal stresler incelen-di. Sıcaklık analizinde taze sığır femur bloklarında dış irrigasyon altında 500 ve 1000 rpm, 20 ve 40 Ncm tork ile 4 ve 8 mm ölçüm derinlikleri K tipi termokupllarla değerlendirildi. Bulgular: Kortikal stresler genel olarak 4 mm'de en yüksek, 10 mm'de en düşük bulundu. Çap artışı kortikal stresleri azaltırken, tork artışı Evoss 3.5 mm mandibula mode-linde stresleri artırdı. İmplant sistemleri ve kemik modelleri arasında farklı stres dağılımları gözlendi. Sıcaklık analizinde 1000 rpm, 8 mm ölçüm derinliği ve Evoss 3.5 mm frezleme protokolü daha yüksek sıcaklıklarla ilişkili bulundu. Tüm sıcaklık değerleri 47°C'nin al-tında kaldı. Sonuç: İmplant yerleştirilmesi sırasında oluşan peri-implant stres dağılımının imp-lant sistemi, çap, yerleştirme derinliği, tork ve kemik modeline; implant yuvası preparas-yonu sırasında oluşan sıcaklık değişiminin ise frezleme koşulları ve implant sistemine ait frezleme protokolüne bağlı olarak değişebildiği sonucuna varılmıştır.
Özet (Çeviri)
Aim: This study aimed to evaluate the effects of different implant systems, implant diameters, insertion depths, torque values, and bone models on peri-implant stress distri-bution and to assess temperature changes in bone under different drilling conditions du-ring implant site preparation. Material and method: Finite element analysis was performed using Evoss 3.5×10 mm, Evoss 4.8×10 mm, and Nucleoss 3.5×10 mm implant models. Insertion depths of 4, 7, and 10 mm and torque values of 20 and 40 Ncm were evaluated in mandi-bular D2 and maxillary D4 bone models. Von Mises, maximum principal, and minimum principal stresses were assessed in cortical bone, while maximum and minimum principal stresses were evaluated in trabecular bone. For the thermal analysis, fresh bovine femoral bone blocks were subjected to drilling at 500 and 1000 rpm and 20 and 40 Ncm under external irrigation. Temperatures were measured at depths of 4 and 8 mm using K-type thermocouples. Results: Cortical stress values were generally highest at 4 mm and lowest at 10 mm. Increasing implant diameter reduced cortical stresses, whereas increased torque pro-duced higher stresses in the Evoss 3.5 mm mandibular model. Stress distributions diffe-red between implant systems and bone models. In the thermal analysis, 1000 rpm, an 8-mm measurement depth, and the Evoss 3.5 mm drilling protocol were associated with higher temperatures. All recorded temperatures remained below 47°C. Conclusion: Peri-implant stress distribution varied according to implant system, diameter, insertion depth, torque, and bone model, while temperature changes during imp-lant site preparation varied according to drilling conditions and implant-system-specific drilling protocols.
Benzer Tezler
- Farklı açılarla yerleştirilen implantların desteklediği 'overdenture' protezlerde kullanılan ataçmanların in vitro olarak karşılaştırılması
The in vitro comparison of the attachments used in overdentures which are supported by different angulated implants
İKBAL LEBLEBİCİOĞLU KURTULUŞ
- Dental implant dayanak preparasyonunun, dayanak vidasının geri çıkartma torkuna olan etkisi: İn vitro çalışma
The effect of dental implant abutment preparation on removal torque of abutment screw: An in vitro investigation
HAYDAR ALBAYRAK
- Farklı dizayna sahip iki ortodontik mini vidanın stabilite açısından değerlendirilmesi
Evaluation of the stability of two orthodontic mini screws with different designs
YEŞİM YASEMİN GÖLLERLİ
- Farklı tip ve kalınlıklardaki monolitik zirkonya seramiklerin rezin simanların polimerizasyon ve mikrosertliğine etkisi
Effect of the different type and thickness of monolithic zirconia ceramics on the resin cement polymerization and microhardness
İPEK BALEVİ AKKESE
- Farklı buğday unu tiplerinin Halla ekmeği kalitesi üzerine etkisi
The effect of wheat flour types on Challah bread quality
IŞIK KARAKOÇ