Lösemi tedavisinde kullanılan azasitidinin farmasötik formlardan, ticari serumdan ve çevre materyallerinden tayini için moleküler baskılanmış polimer tabanlı elektrokimyasal sensör geliştirilmesi
Development of a molecularly imprinted polymer-based electrochemical sensor for the determination of leukemia drug azacitidine from pharmaceutical forms, commercial serum, and environmental matrices
- Tez No: 1030893
- Danışmanlar: PROF. DR. AYŞEGÜL GÖLCÜ
- Tez Türü: Yüksek Lisans
- Konular: Kimya, Chemistry
- Anahtar Kelimeler: Moleküler baskılı polimer, Molecularly imprinted polymer
- Yıl: 2026
- Dil: Türkçe
- Üniversite: İstanbul Teknik Üniversitesi
- Enstitü: Lisansüstü Eğitim Enstitüsü
- Ana Bilim Dalı: Kimya Ana Bilim Dalı
- Bilim Dalı: Kimya Bilim Dalı
- Sayfa Sayısı: Belirtilmemiş.
Özet
Azasitidin (AZA), akut miyeloid lösemi (AML) ve miyelodisplastik sendrom (MDS) gibi hematolojik hastalıkların tedavisinde kullanılan önemli bir antineoplastik ilaç etken maddesidir. AZA'nın farmasötik formülasyonlarda ve biyolojik örneklerde doğru, hızlı, duyarlı ve seçici şekilde tayin edilebilmesi, ilaç kalite kontrolü, tedavi takibi, doz güvenliği ve farmakokinetik değerlendirmeler açısından büyük önem taşımaktadır. Bununla birlikte, AZA'nın düşük derişimlerde bulunması ve ticari serum, farmasötik formülasyon, musluk suyu ve toprak gibi karmaşık matrislerde çeşitli girişimci bileşenlerin bulunabilmesi, analitik tayin sürecini zorlaştırmaktadır. Bu nedenle, klasik analiz yöntemlerine alternatif olarak düşük maliyetli, hızlı, hassas, seçici ve uygulanabilir elektrokimyasal sensör sistemlerinin geliştirilmesi güncel analitik kimya çalışmaları açısından önemlidir. Bu tez çalışmasında, AZA'nın kantitatif tayinine yönelik yüksek seçicilikte moleküler baskılanmış polimer (MIP) tabanlı elektrokimyasal sensörlerin geliştirilmesi amaçlanmıştır. Bu amaç doğrultusunda, camsı karbon elektrot yüzeyinde elektropolimerizasyon (EP) ve fotopolimerizasyon (FP) olmak üzere iki farklı polimerizasyon yaklaşımı kullanılarak AZA'ya özgü tanıma bölgeleri içeren MIP sensör platformları hazırlanmıştır. Sensör performansını artırmak amacıyla amin fonksiyonelli çok duvarlı karbon nanotüp (NH2-MWCNT) modifikasyonundan yararlanılmıştır. NH2-MWCNT'nin yüksek yüzey alanı, iyi elektriksel iletkenliği ve fonksiyonel yüzey yapısı sayesinde elektrot yüzeyinde daha etkin elektron transferinin sağlanması ve analitik sinyalin güçlendirilmesi hedeflenmiştir. Ayrıca nanoparçacık içeren ve içermeyen sensörler karşılaştırılarak NH2-MWCNT modifikasyonunun analitik performans üzerindeki etkisi değerlendirilmiştir. Hazırlanan sensörlerin yüzey ve elektrokimyasal karakterizasyonları taramalı elektron mikroskobu (SEM), zayıflatılmış toplam yansıma-Fourier dönüşümlü kızılötesi spektroskopisi (ATR-FTIR), dönüşümlü voltametri (DV), diferansiyel puls voltametrisi (DPV) ve elektrokimyasal empedans spektroskopisi (EIS) teknikleri kullanılarak gerçekleştirilmiştir. SEM analizleri, elektrot yüzeyinde polimerik tabakanın oluştuğunu ve NH2-MWCNT modifikasyonunun yüzey morfolojisini belirgin biçimde değiştirdiğini göstermiştir. ATR-FTIR sonuçları, MIP ve NIP yapılarının kimyasal bileşenlerini ve şablon uzaklaştırma sonrası meydana gelen yapısal değişimleri desteklemiştir. DV, DPV ve EIS ölçümleri, elektrot yüzeyinde gerçekleşen modifikasyon, şablon uzaklaştırma ve yeniden bağlanma basamaklarının elektrokimyasal olarak izlenebildiğini ortaya koymuştur. Sensör hazırlama koşullarının optimize edilmesi amacıyla şablon/monomer oranı, damlatma hacmi, elektropolimerizasyon döngü sayısı, tarama hızı, fotopolimerizasyon süresi, uzaklaştırma çözeltisi, uzaklaştırma süresi ve yeniden bağlanma süresi gibi xxvi parametreler incelenmiştir. Optimizasyon çalışmaları sonucunda, AZA'ya özgü tanıma boşluklarının etkin şekilde oluşmasını ve yeniden bağlanma sonrası güçlü analitik yanıt elde edilmesini sağlayan deneysel koşullar belirlenmiştir. Nanoparçacık içermeyen EP-AZA@MIP/CKE ve FP-AZA@MIP/CKE sensörleri 1.0 × 10-12–1.0 × 10-11 M derişim aralığında doğrusal yanıt göstermiştir. Ancak NH2-MWCNT modifikasyonu sonrasında sensörlerin doğrusal çalışma aralığı 5.0 × 10-13–1.0 × 10-11 M aralığına genişlemiş ve tayin sınırı değerlerinde belirgin bir iyileşme sağlanmıştır. Nanoparçacık modifiyeli EP-AZA@MIP/NH2-MWCNT/CKE sensörü için teşhis sınırı ve tayin alt sınırı sırasıyla 9.39 × 10-15 M ve 3.12 × 10-14 M olarak hesaplanırken, FP-AZA@MIP/NH2-MWCNT/CKE sensörü için bu değerler sırasıyla 8.63 × 10-15 M ve 2.87 × 10-14 M olarak bulunmuştur. Bu sonuçlar, NH2-MWCNT modifikasyonunun düşük derişimlerde AZA tayin kapasitesini önemli ölçüde artırdığını göstermektedir. Geliştirilen sensörlerin pratik uygulanabilirliği, ticari serum, farmasötik formülasyon, musluk suyu ve toprak örneklerine ekleme-geri kazanım çalışmaları ile değerlendirilmiştir. Ticari serum ortamında AZA derişimleri klinik değerlendirmeye daha uygun olması amacıyla pg/mL biriminde verilmiş ve her iki sensör için 0.12–2.44 pg/mL aralığında doğrusal yanıt elde edilmiştir. Ticari serum örneklerinde EP ve FP sensörleri için ortalama geri kazanım değerleri sırasıyla % 99.06 ve % 102.59 olarak bulunmuştur. Farmasötik numunelerde geri kazanım değerleri EP sensörü için % 102.17, FP sensörü için % 98.19 olarak hesaplanmıştır. Musluk suyu ve toprak numunelerinde de %100'e yakın geri kazanım değerleri elde edilmiş; düşük bağıl standart sapma değerleri, yöntemin tekrarlanabilirliğini desteklemiştir. Sensörlerin seçicilik performansı, AZA'ya yapısal benzerlik gösteren sitarabin ve klofarabin varlığında değerlendirilmiştir. MIP sensörlerinin NIP sensörlere kıyasla AZA'ya karşı daha yüksek yanıt vermesi, oluşturulan baskılanmış boşlukların hedef moleküle özgü tanıma sağladığını göstermiştir. Ayrıca dopamin, parasetamol, askorbik asit, ürik asit ve çeşitli inorganik iyonlar gibi potansiyel girişimci türlerin varlığında yapılan çalışmalar, geliştirilen sensörlerin karmaşık matrislerde AZA'yı seçici ve güvenilir bir şekilde tayin edebildiğini ortaya koymuştur. Ayrıca, MIP tabanlı sensörlerin atomik düzeydeki tanıma mekanizmasını açıklamak amacıyla Yoğunluk Fonksiyoneli Teorisi (Density Functional Theory, DFT) temelli moleküler modelleme çalışmaları yürütülmüştür. Yüzey-ayırma analizleri, fonksiyonlandırılmış karbon nanotüpün tanıma sürecine aktif olarak katılarak bağlanma afinitesini artırdığını; elektropolimerize kompleks modellemesi ise anilin ko-monomerinin baskılanmış boşluğun kararlılığını ve elektron transferini desteklediğini göstermiştir. Çalışma kapsamında geliştirilen sensörlerin sürdürülebilirlik profilleri AGREE ve AGREEMIP metrikleriyle değerlendirilmiştir. EP ve FP yöntemleriyle hazırlanan sensörler; düşük örnek hacmi, sınırlı reaktif tüketimi, kısa analiz süresi ve düşük enerji gereksinimi sayesinde yeşil analitik kimya ilkeleriyle uyumlu bulunmuştur. Genel olarak sonuçlar, NH2-MWCNT modifiyeli MIP tabanlı elektrokimyasal sensörlerin AZA'nın farmasötik, biyolojik ve çevresel örneklerde hızlı, duyarlı, seçici ve güvenilir bir şekilde tayin edilmesi için alternatif bir analitik yaklaşım sunduğunu göstermektedir.
Özet (Çeviri)
Azacitidine (AZA) is an important antineoplastic drug used to treat hematological disorders, particularly acute myeloid leukemia (AML) and myelodysplastic syndromes (MDS). As a cytidine analog and hypomethylating agent, AZA plays a significant role in epigenetic therapy by inhibiting DNA methyltransferase activity and contributing to the reactivation of silenced genes. The reliable determination of AZA in pharmaceutical formulations and biological samples is therefore essential for drug quality control, treatment monitoring, dose safety, and pharmacokinetic evaluation. In addition, determining AZA in environmental matrices may be important, given the potential release of pharmaceutical residues into aqueous and soil environments. However, the analysis of AZA is challenging because the drug may be present at very low concentration levels and may coexist with various interfering species in complex sample matrices such as synthetic serum, pharmaceutical formulations, tap water, and soil. Conventional analytical methods used for drug determination, including chromatographic and mass spectrometric techniques, can provide high accuracy and sensitivity. Nevertheless, these methods generally require expensive instrumentation, trained personnel, relatively long analysis times, and considerable solvent consumption. These limitations increase the need for alternative analytical platforms that are rapid, sensitive, selective, low-cost, and suitable for practical applications. Electrochemical sensors are promising tools in this regard because they offer high sensitivity, short response time, low sample consumption, relatively simple operation, and compatibility with miniaturized and portable systems. However, one of the major challenges in electrochemical sensing is achieving sufficient selectivity for the target molecule, especially in complex matrices containing structurally similar compounds and electroactive interferents. Molecularly imprinted polymers (MIPs) provide an effective strategy to overcome this selectivity limitation. MIPs are synthetic recognition materials prepared by polymerizing functional monomers and cross-linkers in the presence of a target molecule used as a template. After polymerization, the template molecule is removed from the polymer matrix, leaving recognition cavities complementary to the target in size, shape, and functional group arrangement. These artificial binding sites enable selective rebinding of the target molecule, even in complex sample environments. Owing to their chemical stability, low cost, ease of preparation, and high recognition ability, MIPs have attracted considerable attention in the development of selective electrochemical sensors for pharmaceutical and biological analysis. xxviii The aim of this thesis was to develop highly selective MIP-based electrochemical sensors for the quantitative determination of AZA. For this purpose, two different polymerization strategies, namely electropolymerization (EP) and photopolymerization (PP), were employed on glassy carbon electrode surfaces. Using these two approaches, AZA-imprinted sensor platforms were prepared and compared for surface characteristics, electrochemical behavior, analytical performance, selectivity, and applicability to real samples. Besides the polymerization approach, the influence of nanomaterial modification was assessed by adding amino-functionalized multi-walled carbon nanotubes (NH2-MWCNTs) to the sensor. NH2-MWCNTs were chosen for their high surface area, excellent electrical conductivity, functional surface groups, and capacity to improve electron transfer at the electrode interface. In the electropolymerization approach, the MIP layer was formed directly on the glassy carbon electrode surface via electrochemical polymerization of the monomer mixture in the presence of AZA. This method enabled controlled film formation on the electrode surface and allowed the polymer thickness to be adjusted by varying electrochemical parameters such as the number of cycles and the scan rate. In the photopolymerization-based approach, the polymeric film was formed under ultraviolet irradiation from a photopolymerization mixture containing AZA, functional monomers, a cross-linker, a photoinitiator, and NH2-MWCNTs. This approach enabled quick polymer formation under gentle conditions and offered an alternative method for creating MIP-based recognition layers. For both EP and PP systems, non-imprinted polymer (NIP) sensors were also produced under similar conditions but without the template molecule to assess the specific role of molecular imprinting. The sensor fabrication involved several essential steps: cleaning the electrodes, modifying the surface with NH2-MWCNTs, forming the AZA-imprinted polymer layer, removing the template molecule, and allowing AZA to rebind into the imprinted cavities. Removing the template was essential because creating accessible recognition cavities directly affects the sensor's sensitivity and selectivity. After AZA to be removed from the polymer matrix, the rebinding step allowed it to be removed again, enabling the target molecule to interact selectively with the imprinted sites. The analytical response was tracked electrochemically with the ferri/ferrocyanide redox probe system. Variations in current response and charge transfer resistance helped assess each modification, removal, and rebinding process. The prepared sensors were analyzed using surface and electrochemical methods. Scanning electron microscopy (SEM) was used to examine the surface structure of the modified electrodes. SEM images confirmed that polymeric layers were effectively applied to the electrode surfaces and revealed that NH2-MWCNT modification resulted in significant alterations in surface morphology. The surfaces with nanotube modification showed a more developed and heterogeneous structure, which helps to increase the active surface area and enhances the electrochemical response. Attenuated total reflectance-Fourier transform infrared spectroscopy (ATR-FTIR) was employed to analyze the chemical structure of the MIP and NIP layers and to confirm the formation of the polymeric matrix. The observed changes following template removal revealed structural differences related to the elimination of AZA from the imprinted polymer. xxix The sensors' electrochemical behavior was assessed through cyclic voltammetry (CV), differential pulse voltammetry (DPV), and electrochemical impedance spectroscopy (EIS). CV and DPV measurements clearly showed the changes at the electrode surface during polymer formation, template removal, and AZA rebinding. After polymer formation, the redox probe signal decreased because the polymer layer partially blocked electron transfer. After removing the template, the current increased because the imprinted cavities made it easier for the redox probe to reach the electrode surface. Following AZA rebinding, the current decreased again as the target molecules occupied the cavities, preventing electron transfer. This pattern confirmed the successful creation of the MIP sensors and showed that the imprinted polymer layer could specifically recognize target molecules. EIS measurements further confirmed the step-by-step modification of the electrode surface. The charge-transfer resistance increased after the polymeric film formed, indicating that the polymer layer impeded electron transfer. Once the template was removed, a notable decrease in resistance was seen, showing that accessible cavities had formed within the polymer matrix. Subsequent AZA rebinding increased resistance due to the target molecule occupying these cavities. The comparison between MIP and NIP sensors revealed that MIP systems exhibited more pronounced changes during the removal and rebinding phases, indicating the presence of specific recognition sites. Additionally, the lower resistance values recorded with NH2-MWCNT-modified sensors highlighted the advantageous role of nanotubes in enhancing the conductivity of the sensing interface. Various experimental parameters were optimized to ensure the most accurate and consistent analytical results. These included the template-to-monomer ratio, drop-casting volume in the photopolymerization system, number of electropolymerization cycles, scan rate, photopolymerization duration, removal solvent, removal duration, and rebinding time. These parameters critically affect the polymer layer's structure, the accessibility of imprinted cavities, and the overall efficiency of target rebinding. Optimization studies helped identify optimal preparation and measurement conditions for both EP- and PP-based MIP sensors. The chosen conditions ensured adequate polymer coverage while preserving effective electron transfer and high AZA recognition. The analytical performance of the developed sensors was evaluated using standard AZA solutions. First, the performance of nanoparticle-free MIP sensors was assessed. Both EP-AZA@MIP/GCE and PP-AZA@MIP/GCE sensors exhibited linear responses over the concentration range of 1.0 × 10-12–1.0 × 10-11 M. Then, NH2-MWCNT-modified MIP sensors were examined. After nanomaterial modification, the linear working range was extended to 5.0 × 10-13–1.0 × 10-11 M, indicating that NH2-MWCNTs improved the sensors' detection capability at lower AZA concentrations. For the EP-AZA@MIP/NH2-MWCNT/GCE sensor, the limit of detection and limit of quantification were calculated as 9.39 × 10-15 M and 3.12 ×10-14 M, respectively. For the PP-AZA@MIP/NH2-MWCNT/GCE sensor, these values were 8.63 × 10-15 M and 2.87 × 10-14 M, respectively. These findings showed that both sensor platforms achieved highly sensitive AZA detection, with NH2-MWCNT modification notably improving analytical performance. xxx The practical use of the developed sensors was evaluated across various sample matrices, including synthetic serum, pharmaceutical formulations, tap water, and soil. In serum samples, AZA concentrations were evaluated in pg/mL to better reflect biologically relevant concentrations. Both EP and PP sensors showed linear responses in the range of 0.12–2.44 pg/mL. The average recovery values from synthetic serum samples were nearly 100%, demonstrating that the developed method is effective for biological matrices. Additionally, the sensors were used with pharmaceutical samples, producing satisfactory recovery results for both EP and PP systems. Furthermore, the analysis of tap water and soil samples showed that the sensors could reliably determine AZA in environmental matrices. The low relative standard deviation values obtained in these studies confirmed the repeatability and practical reliability of the proposed method. Selectivity is a key performance criterion for MIP-based sensors. Consequently, the developed sensors' selectivity was tested with structurally similar drugs, cytarabine and clofarabine. The MIP sensors showed stronger responses to AZA than to structurally similar compounds, whereas the NIP sensors exhibited lower and less specific responses. These findings confirmed that the imprinting process generated selective recognition cavities for AZA. The results on relative selectivity indicated that both EP- and PP-based MIP sensors could differentiate AZA from comparable molecules, confirming the successful creation of target-specific binding sites. The study also evaluated how potential interfering species might affect sensor performance in complex samples. Inorganic ions and electroactive substances—such as dopamine, paracetamol, ascorbic acid, and uric acid—were tested as possible interferents. The results demonstrated that these species did not lead to notable deviations in the AZA response. This suggests that the MIP-based sensors developed can uphold analytical reliability despite the presence of common interfering compounds. The integration of molecular imprinting with NH2-MWCNT modification improved both selective molecular recognition and increased electrochemical signal output. Apart from analyzing performance, the sustainability of the developed methods was assessed using green analytical chemistry tools. The EP and PP methods were examined based on reagent consumption, sample volume, waste generation, analysis time, energy use, and overall environmental impact. Both sensor preparation strategies exhibited favorable features, including low sample volume, limited reagent consumption, short analysis time, and compatibility with electrochemical detection. Using MIP-based recognition layers enhances sustainable analytical methods by enabling selective detection with minimal sample prep. These findings show that the sensors created are not only highly sensitive and selective but also align with the principles of greener analytical chemistry. This thesis details the development, characterization, optimization, and use of NH2-MWCNT-modified MIP-based electrochemical sensors for accurately measuring azacitidine. It successfully employs and compares two fabrication methods: electropolymerization and photopolymerization. The results indicated that both methods are effective for developing AZA-selective MIP sensor platforms. Adding NH2-MWCNTs enhanced their electrochemical performance by boosting conductivity and facilitating better electron transfer. The sensors achieved low detection limits, broad linear ranges, reliable recovery, good selectivity, and consistent repeatability. xxxi Additionally, molecular modeling using Density Functional Theory (DFT) was performed to clarify how the MIP-based sensors recognize substances at the atomic level. Surface-decoupling analyses showed that the functionalized carbon nanotube plays an active role in recognition, which enhances binding strength. Furthermore, modeling of the electropolymerized complex demonstrated the cooperative function of the aniline co-monomer, which not only improved the thermodynamic stability of the imprinted cavity but also reduced the HOMO-LUMO energy gap, offering theoretical support for the sensor's electrical conductivity and electron-transfer kinetic. This thesis demonstrates that MIP-based electrochemical sensors are effective alternatives to conventional methods for detecting AZA. These sensors offer multiple advantages, including rapid response times, cost-effectiveness, high sensitivity, excellent selectivity, and adaptability to different sample types. The EP-AZA@MIP/NH2-MWCNT/GCE and PP-AZA@MIP/NH2-MWCNT/GCE sensors developed demonstrate potential for detecting AZA in pharmaceutical, biological, and environmental samples. More broadly, this research also advances nanomaterial-supported MIP-based electrochemical sensors for drug analysis and can inform future research aimed at selectively measuring similar pharmaceutical compounds.
Benzer Tezler
- Sivas yöresinde akraba evliliği yapan ve yapmayan çiftlerde dermatoglifik benzerlikler
Similarities of dermataoglyphies among individval of married relatives and married couples not related to each other in Sivas region
Y. SELMA SÜNGÜ
- Malignite ile tek gen mutasyonları ve kromozom düzensizliklerinin ilişkisi üzerine araştırmalar
Investigations on the relationship between malignancy and a single gene mutation and chromosomal abnormalities
M. NAİL ALP
- Kararlı şartlarda kontrollu katılaştırılmış Zn+%4A1 ve Zn+%4A1 (Cu, Fe ve Mg ilaveli) alaşımlarında mikroyapı ve bileşen dağılımı
Başlık çevirisi yok
AHMET ALTMIŞOĞLU