Geri Dön

Kennedy sınıf III dişsizlik olgularında üç farklı tür hassas tutucunun kuvvet iletimi yönünden karşılaştırılması

The comparison of the spesification of force distribution of three types of precision attachments used in kennedy class III partially edentulous arches

  1. Tez No: 129859
  2. Yazar: BURCU AVCI DEMİRALP
  3. Danışmanlar: PROF. DR. MUTAHHAR ULUSOY
  4. Tez Türü: Doktora
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Direkt tutucular, fotoelastik kuvvet analizi, hareketli bölümlü protez, hassas tutucular, kuvvet iletimi, Direct retainers, load transmission, photoelastic stress analysis, precision attachments, removable partial denture
  7. Yıl: 2003
  8. Dil: Türkçe
  9. Üniversite: Ankara Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

73 ÖZET Kennedy Sınıf m Dişsizlik Oiguiarında Üç Farklı Tür Hassas Tutucunun Kuvvet İletimi Yönünden Karşılaştırılması Çalışmamızda Klas III oiguiannda kullanılan üç ana gruptaki (rezilient, rijid ve yarı- rijid) hassas tutucuların destek dişlere ilettiği kuvvetlerin fotoelastik stres analizi yöntemi ile invitro, karşılaştırmalı olarak incelenmesi amaçlandı. Ağız ortamını yansıtan modelin hazırlanması amacıyla Kennedy Sınıf III / Modifikasyon I vakasına uyan alçı modelden silikon esaslı ölçü maddesi ile negatif elde edildi ve bu negatif içerisine pembe mum eritilerek, alçı modelin mum dublikatı hazırlandı. Cr-Co alaşımından döküm yolu ile elde edilen metal dişlerin periodontal membranı silikon esaslı ölçü maddesinden oluşturuldu. Dişler mum modele gömülerek model üzerinden, iki fazlı silikon esaslı ölçü maddesi ile ölçü alındı. Ölçü içerisindeki mum kaynatılarak oluşan boşluğa fotoelastik rezin (PL-2) dökülerek model elde edildi. Model üzerinde VKS-SG (esnek, rijid ve yarı-rijid tip), Ceka-Revax, ASC-52, Special series stress breaker, Miniancor rijid attachment, NAB-92, Rod attachment, AP-Piccolino, Klinat-98 ve Preci- Vertex hassas tutucularını içeren altı adet iskelet bölümlü protez hazırlandı. Herbir hassas tutucunun kuvvet iletim özelliklerini değerlendirmek amacıyla ODTÜ Makine Mühendisliği Bölümü Fotoelastisite laboratuvannda, herbir protez ayrı ayrı model üzerine oturtularak polariskop cihazı üzerine yerleştirilerek çift taraflı dikey ve tek taraflı dikey, mesial ve distal yönlü kuvvetler uygulandı. Yüklemeler sonucu modelde oluşan renkli kuvvet çizgileri polariskop cihazında gözlendi ve fotoğrafları çekildi. Çalışmamızın sonucunda Amortisör ve NAB-92' nin en olumsuz hassas tutucular olmuş bunları Miniancor, AP-Piccolino ve Bredent esnek tip izlemiştir. En az gerilim ise ASC-52 ve Bredent yarı-rijid tipte görülmüştür.

Özet (Çeviri)

74 SUMMARY The comparison of the spesification of force distribution of three types of precision attachments used in Kennedy Class III partially edentulous arches. In this study we evaluated the load transmission characteristics to the abutment teeth of mandibular Kennedy Class III removable partial dentures designed with three different types of precision attachments by using photoelastic stress analysis method. The model, simulating the in vivo situation, was prepared with photoelastic resin named as PL-2. The condensation type silicone impression material was used to simulate the periodontal ligament of the abutment teeth which had been casted with Cr-Co alloy. A total of six removable partial dentures carrying, VKS-SG (resilient, rigid and semi-rigid type), Ceka-Revax, ASC-52, Special series stress breaker, Miniancor rigid attachment, NAB-92, Rod attachment, AP-Piccolino, Klinat-98 and Preci- Vertex attacchments, were produced. Bilateral vertically and unilateral vertically, mesially and distally directed loads were applied to the prostheses and the fringes which appeared on the polariscop were photographed. As a result of this investigation, it was determined that special series stress breaker and NAB-92 were the worst precision attachments in distributing loads. These attachments were followed by Miniancor rigid attachment, AP-Piccolino and Bredent resilient type attachments. ASC-52 and Bredent semi-rigid type attachments were the most favorable attachments in load transmission.

Benzer Tezler

  1. Parsiyel diş eksikliğinde çeşitli intraoral tarayıcı ve 3 boyutlu yazıcı ile elde edilen ölçülerin ve çalışma modellerin İn-Vivo olarak değerlendirilmesi

    Accuracy of impression and model obtained from different digital techniques in partial edentulism In Vivo

    SİNEM İŞLER KAYA

    Doktora

    Türkçe

    Türkçe

    2025

    Diş HekimliğiMarmara Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. ŞEBNEM BEGÜM TÜRKER

  2. Kısmi dişsizlik durumlarında görülen temporomandibular eklem rahatsızlıklarının protetik tedaviden önce ve sonra manyetik rezonans görüntüleme yöntemi ile değerlendirilmesi

    The Evaluation of temporomandibular joint disorders observeding the case of partial edentulous through magnetic resonance imagine before and after prosthetic rehabilitation

    KORHAN BÖKE

    Doktora

    Türkçe

    Türkçe

    2000

    Diş HekimliğiAnkara Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF.DR. YÜKSEL TÜRKÖZ

  3. İmplant yerleşim derinliğinin, posterior diş varlığının ve farklı tarama stratejilerinin dijital ölçü doğruluğu ve hassasiyeti üzerine etkisi

    The impact of implant placement depth, posterior tooth presence and scanning strategies on accuracy and precision of partial edentulism

    BÜŞRA BOZDOĞAN

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2024

    Diş HekimliğiAydın Adnan Menderes Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ ESRA TALAY ÇEVLİK

    DOÇ. DR. MEHMET ESAD GÜVEN

  4. Üst çene ana bağlayıcıların optimizasyonu

    Optimization of maxillary major connectors

    İPEK AÇIKBAŞ

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2022

    Diş HekimliğiSelçuk Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. SERHAN AKMAN

  5. Parsiyel protezlerde ölçü metodlarının karşılaştırılması

    Başlık çevirisi yok

    İSLAM İSLAMOĞLU

    Doktora

    Türkçe

    Türkçe

    1986

    Diş Hekimliğiİstanbul Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. NURİ MUĞAN