Buzdolaplarında kullanılan seri sıralamalı (tandem) sistemlerin deneysel ve teorik incelenmesi

Experimental and theoretical investigation of the serial arrangement (tandem) refrigeration system in refrigerators

  1. Tez No: 151583
  2. Yazar: TALİP ÇAĞLAR
  3. Danışmanlar: PROF. DR. NİLÜFER EĞRİCAN
  4. Tez Türü: Yüksek Lisans
  5. Konular: Makine Mühendisliği, Mechanical Engineering
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2004
  8. Dil: Türkçe
  9. Üniversite: İstanbul Teknik Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Makine Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

BUZDOLAPLARINDA KULLANILAN SERİ SIRALAMALI (TANDEM) SİSTEMLERİN DENEYSEL VE TEORİK İNCELENMESİ ÖZET Buzdolaplarında kullanılagelen çift buharlaştırıcılı, seri sıralamalı soğutma çevrimierinde temel olarak iki verimsizlik mevcuttur. Bunlardan ilki buzolabtnda yer alan taze gıda bölmesinin gerekenden daha düşük bir buharlaşma basıncında ve sıcaklığında soğutulmasıdır. Düşük buharlaşma sıcaklıkları kompresörün dolayısıyla da sistemin SHK'ini düşürmektedir. Bu nedenle taze gıda bölmesi için gerekenden daha düşük bir buharlaşma basıncında (buharlaşma sıcaklığında) soğutma yapılması verimsiz bir soğutma işlemine sebep olmaktadır. Bunun çözümü için taze gıda bölmesinin, kendisi için daha verimli olan yüksek bir buharlaşma basıncında yani buharlaşma sıcaklığında soğutulması gerekmektedir. Bunu yaparken ise bu çalışmada kompresörün kalkış anından itibaren başlayan ve çevrim alt ve üst basınçları (buharlaşma ve yoğuşma basınçları) dengeye gelene kadar devam eden geçici rejim koşullan (aralığı) taze gıda bölmesinin soğutulmasında kullanılmıştır. Geçici rejim süresinden etkin bir şekilde yararlanmak için taze gıda buharlaştıncısı olarak zorlanmış taşınımlı bir bııharlaştırıcı kullanılmıştır. Diğer bir verimsizlik ise dondurucu buharlaştıncısı tanının çalışma zamanlamasından kaynaklanmaktadır. Kompresörün durmasıyla birlikte yüksek basınçlı basma hattı ile düşük basınçlı emme hattı arasındaki basınç farkından ötürü bir soğutkan göçü meydana gelmektedir. Bu göç neticesinde kompresör çalışmaz iken buharlaştırıcılar ısınmakta ve kompresörün çalışmaya başlamasıyla birkaç dakika bölmelerini soğutamamakta aksine bölmelerine ısıtabilmektedirier. Bu yüzdendir ki, kompresörün çalışmaya başlamasıyla birlikte özellikle dondurucu buharlaştıncısı fanının da çalışmaya başlaması dondurucu bölmesinin ısı yükünü artırmaktadır. Bu durumun çözümü için ise dondurucu fanı kompresör çalışmasını takiben belli bir süre sonra çalıştırılmıştır.

Özet (Çeviri)

EXPERIMENTAL AND THEORETICAL INVESTIGATION OF THE SERIAL ARRANGEMENT (TANDEM) REFRIGERATION SYSTEM IN REFRIGERATORS SUMMARY The current conventional domestic serial cycles have two main inefficiencies. One of said inefficiencies is inappropriate pressure levels for cooling fresh food compartment. Lower evaporation pressure than required degrades COP of compressor and refrigeration system. Therefore, the refrigeration cycle operates inefficiently to keep the fresh food compartment at desired temperatures with inappropriate (lower) evaporation levels. In this study, transient regime was used to cool fresh food compartment. During the transient regime, evaporation temperature and pressure levels are suitable to provide efficient cooling for the fresh food compartment while evaporation pressure and temperature are higher than desired levels for the freezer compartment. Fresh food evaporator was changed from cold- wall natural-convection heat exchanger to forced-convection heat exchanger to enhance the transient regime effects on cooling of fresh food compartment. The other inefficiency is related to the start time of freezer evaporator fan according to the compressor. When the compressor starts to operate, the FRZ evaporator can't cool its compartment in first few minutes because of increased evaporator temperature due to refrigeration migration during the compressor off period. Moreover, working of the freezer fan in this period cause extra heat load to the its cabinet. Therefore, in this study, freezer fan was started to operate after the adequate time of the compressor initiation.

Benzer Tezler

  1. A Numerical study of the air motion inside a frost-refrigerator

    Cebri hava dolaşımlı bir buzdolabı içindeki hava hareketinin sayısal bir çalışması

    AYHAN GÖKBAĞ

    Yüksek Lisans

    İngilizce

    İngilizce

    1995

    Boğaziçi Üniversitesi

    Yükleniyor...

  2. Thermoeconomic optimisation of simple refrigerators

    Basit buzdolaplarının termoekonomik optimizasyonu

    HALDUN DİNGEÇ

    Yüksek Lisans

    İngilizce

    İngilizce

    1996

    Orta Doğu Teknik Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    Yükleniyor...

  3. Ankara ilindeki eczanelerde soğuk-zincir konusunda uygulamalar

    Cold chain practices in the pharmacies in Ankara

    A. NİLÜFER ÖZAYDIN

    Yüksek Lisans

    Türkçe

    Türkçe

    1997

    Hacettepe Üniversitesi

    Halk Sağlığı Ana Bilim Dalı

    Yükleniyor...

  4. Kesici takımların performansına takım malzemesinin ve tin kaplamanın etkisi

    The Effect of tool materials and tin coating on the performance of cutting tools

    HAYRETTİN AHLATCI

    Yüksek Lisans

    Türkçe

    Türkçe

    1997

    İstanbul Teknik Üniversitesi

    Metalurji Mühendisliği Ana Bilim Dalı

    Yükleniyor...

  5. A new adaptive defrost method its instrumentation and experimental verfication

    Yeni bir uyarlamalı kar çözme yöntemi donanım ve deneysel doğrulanması

    HİKMET BALCI

    Yüksek Lisans

    İngilizce

    İngilizce

    1999

    Orta Doğu Teknik Üniversitesi

    Elektrik-Elektronik Mühendisliği Ana Bilim Dalı

    Yükleniyor...