Geri Dön

Birinci tirimester down sendromu taramasında Duktus venozus Doppleri'nin nukal translusensi ve serum belirteçleri ile birlikte değerlendirilmesi

The assessment of Ductus venosus Doppler measurements with nukal translucency and serum markers for down syndrome screening in the first trimester

  1. Tez No: 171642
  2. Yazar: ÖZLEM ÖZER
  3. Danışmanlar: PROF.DR. FÜSUN VAROL
  4. Tez Türü: Tıpta Uzmanlık
  5. Konular: Kadın Hastalıkları ve Doğum, Obstetrics and Gynecology
  6. Anahtar Kelimeler: Duktus venozus, Down sendromu, ilk trimester, tarama. 87, Ductus venosus, Down syndrome, first trimester, screening. 89
  7. Yıl: 2006
  8. Dil: Türkçe
  9. Üniversite: Trakya Üniversitesi
  10. Enstitü: Tıp Fakültesi
  11. Ana Bilim Dalı: Kadın Hastalıkları ve Doğum Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 101

Özet

ÖZET Çalışmamızın amacı mevcut birinci trimester Down sendromu tarama protokolü olan Nukal Translusensi ve serum belirteçlerine fetal Duktus venozus Doppler çalışmalarının katkısını araştırmaktı. Prospektif olarak yapılan bu çalışmada, gebeliğin 11-14. haftalarından itibaren takip edilen olguların, istatiksel analizlerinde kullanılan risk sınır değerleri daha önce yayınlanan literatürlerden elde edildi. Çalışmaya alınan 213 fetusta anne yaşı, Nukal Translusensi ile Pregnancy associated plasma protein A ve serbest beta Human koryonik gonadotropin! içeren anne serum belirteçleri ve 212 fetusun Duktus venozus Doppler Pulsatilite indeksi değerleri ölçüldü, A dalgası dikkatle değerlendirildi. Ardından 185/213 olguya Alfa-fetoprotein, human koryonik gonadotropin ve Unconjugated estriol'den oluşan üçlü tarama testi uygulandı. Tüm gebeler ayrıntılı Ultrasonografi ile yapısal anomali taramasına alındı. Her tarama testi sonunda risk değerlendirilmesi yapıldı (ardışık test) ve riskli bulunanlara kesin tanısı için invaziv bir metot olan amniyosentez önerildi. İkili tarama testinde yüksek risk saptanan iki gebenin amniyosentez sonucu Down sendromu olarak bildirildi. Bunlardan birinde Nukal translusensi kalınlığı 3,6 mm (> 95. persantil), Duktus venozus Doppler Pulsatilite indeksi değeri 0,98 (< 95. persantil) ölçüldü ve A dalgası normaldi. Down sendromlu diğer gebenin Nukal translusensi kalınlığı 1,6 mm (< 95. persantil) idi. Ardışık test, diğer testlere göre Down sendromu saptama oram en yüksek tarama metotlarından olsa bile, yüksek invaziv girişim ihtiyacına neden olmaktadır. 86İkili tarama testinin önemli bir aşaması olan Nukal translusensi'nin belirlenmesi, standardize edilmiş kriterler ile değerlendirilmesi gerekliliğini getirdiğinden, işlemi yapan kişilerin eğitilmesini zorunlu kılmaktadır. Duktus venozus Doppler çalışması için ise daha ileri araştırmalara gerek vardır.

Özet (Çeviri)

THE ASSESSMENT OF DUCTUS VENOSUS DOPPLER MEASUREMENTS WITH NUKAL TRANSLUCENCY AND SERUM MARKERS FOR DOWN SYNDROME SCREENING IN THE FIRST TRIMESTER SUMMARY The aim of our sudy was to improve based on Nuchal translucency and serum markers Down syndrome screening methods by enclosing fetal Ductus venosus Doppler measurements. In this prospective study, the cut off values for Down syndrome risk analysis in the pregnancies followed between 11 and 14 weeks were obtained from the previous literatures. Maternal age, Nuchal translucency, Pregnancy associated plasma protein A and free beta Human chorionic gonadotropin values were measured in 213 fetuses and Ductus venosus Doppler pulsatilite index done in 212 fetuses. The existence of A wave was carefully analysed. Of 185 213 cases nipple test based on Alfa-fetoprotein, Human chorionic gonadotropin and Unconjugated estriol measurements were obtained. The level II ultrasound examinations were carried out in all pregnant women in this study. The risk assessment was made after every screening test (sequential test) and then amniocentesis was offered for definitive diagnosis to those who were at high risk. After all, two Down syndrome cases were diagnosed via amniocentesis which performed in high risk population of testing. In one of these two, Nuchal translucency thickness was 3,6 mm (> 95th percentile), Ductus Venosus Doppler Pulsatilite index value 88was 0,98 (< 95th percentile) and the A wave was normal. The Nuchal translucency thickness of other Down syndrome was 1,6 mm (< 95th percentile). The highest detection rate for Down syndrome was obtained by sequential test, however this may bring excessive rate in invasive procedure. Because the Nuchal translucency measurement, being one of the important step in double test, depends on examiner experience, Nuchal translucency assessment necessiates deep individual training. A further investigations are needed for the establishment of Ductus venosus Doppler studies in Down syndrome screening method.

Benzer Tezler

  1. Birinci ve ikinci trimester taramasına göre yüksek riskli olarak sınıflandırılan gebelerde amniosentez öncesi incelenen fetal duktus venozus akım hızı dalga formu ile fetal sonuçların ilişkisi

    The correlation of fetal ductus venosus flow velocity waveform examined before amniocentesis and fetal outcomes in pregnants classified as high risk according to first and second trimester screening

    GÖKHAN KARAKOÇ

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2010

    Kadın Hastalıkları ve DoğumSağlık Bakanlığı

    Kadın Hastalıkları ve Doğum Ana Bilim Dalı

    DOÇ. DR. AHMET NURİ DANIŞMAN

  2. Down sendromu taramasında kullanılan biyokimyasal belirteçlerin olumsuz gebelik sonuçlarını öngörmede yeri

    Prediction of adverse pregnancy outcomes with biochemical markers used in down syndrome screening

    ASLIHAN YAZICIOĞLU

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2013

    Kadın Hastalıkları ve DoğumHacettepe Üniversitesi

    Kadın Hastalıkları ve Doğum Ana Bilim Dalı

    DOÇ. DR. ÖZGÜR ÖZYÜNCÜ

  3. Down sendromu taramasında kullanılan birinci ve ikinci trimester maternal serum belirteçlerinin gebelik komplikasyonları ile ilişkisi

    First and second trimester maternal serum down syndrome markers and adverse pregnancy outcomes

    LALE SUSAN KARAKIŞ

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2010

    Kadın Hastalıkları ve DoğumSağlık Bakanlığı

    Kadın Hastalıkları ve Doğum Ana Bilim Dalı

    DOÇ. DR. NEŞE YÜCEL

  4. Tarama testleri ile gebelikte anöploidi riskinin belirlenmesi ve kantitatif floresan polimeraz zincir reaksiyonu ile prenatal tanısı

    Determination of the risk of aneuploidy by screening tests and prenatal diagnosis by quantitative fluorescent polymerase chain reaction

    ZELİHA ÖZEN GÜÇLÜTÜRK

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2011

    BiyokimyaÇukurova Üniversitesi

    Tıbbi Biyokimya Ana Bilim Dalı

    PROF. DR. MEHMET AKİF ÇÜRÜK

  5. 11-13/6 gebelik haftalarında Türk toplumunda fetal nazal kemik uzunluğu nomogramı

    Fetal nasal bone length nomogram in Turkish population at 11-13/6 weeks of gestation

    SERDAR ÖZER

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2008

    Kadın Hastalıkları ve DoğumSağlık Bakanlığı

    Kadın Hastalıkları ve Doğum Ana Bilim Dalı

    DOÇ. MÜZEYYEN GÜLNUR ÖZAKŞİT