Geri Dön

Rijit ve semirijit bağlantılı implant-diş ve implant-implant destekli sabit parsiyel protezlerde kemik içerisinde oluşan stres dağılımının incelenmesi

The evaluation of stress distribution in supporting bone with rigid and semirigid connected implant-tooth and implant-implant supported fixed partial dentures

  1. Tez No: 195213
  2. Yazar: DİLEK ENHOŞ
  3. Danışmanlar: PROF.DR. ÖZGÜR İNAN
  4. Tez Türü: Doktora
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2007
  8. Dil: Türkçe
  9. Üniversite: Selçuk Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 139

Özet

Bu çalısmanın amacı, implant-dis ve implant-implant destekli sabit parsiyel protezlerdeki rijit ve semirijit baglantının destek kemik üzerindeki etkisini, farklı iki stres analiz yöntemi ile karsılastırmalı olarak degerlendirmektir. Bu amaçla üç adet Straumann marka, 4,1mm çapında, 12mm uzunlugunda, solid, vida tipi implant ile bir adet yeni çekilmis, çürüksüz, sag üst II. premolar dis kullanıldı. Dogal dise 6º'lik tepe açısı olan soulder basamaklı preperasyon hazırlandı. Disin kök yüzeyi 0,20-0,30mm kalınlıgında silikon esaslı ölçü maddesi ile kaplandı. 45mmx10mmx50mm boyutlarında hazırlanan akrilik bloklara implantlar ve dogal dis yerlestirildi. mplantların üzerine 50mm yüksekligindeki abutmentları sabitlendi. Metal destekli porselenden hazırlanan örneklerde hassas baglantı ünitesi olarak `T' tipi sürgü baglantısı kullanıldı. Fotoelastik stres analiz yöntemi için PL-2 epoksi rezin kullanıldı. Yükleme için üniversal test cihazı, olusan kuvvet çizgilerini izleyebilmek için ise beyaz ısık ve Polariskop cihazı kullanıldı. Her bir örnege, oklüzal tablanın orta noktasından, vertikal yönde 300N'luk kuvvet uygulandı ve sonuçlar dijital bir fotograf makinesi kullanılarak görüntülendi. Sonlu eleman analiz yöntemi için ise bilgisayar destekli modeller, gerçek boyutlarına uygun olarak bütün yapıların (mine, dentin, pulpa, periodontal ligament, kemik, implant) elastisite modülleri ve poisson oranları belirtilerek ayrı ayrı olusturuldu. Bu amaçla SAP2000 bilgisayar programı kullanıldı. Hazırlanan modellerin 2mm'lik kesitleri. Sonlu eleman modelleme yönteminin bir özelligi olarak bütün yapılar homojen, lineer elastik ve izotropik kabul edildi. Aynı sekilde yükleme yapıldı ve sonuçlar von Misses skalası baz alınarak degerlendirildi. Çalısma sonunda iki stres analiz yöntemine ait bulgular tek tek ve karsılastırmalı olarak degerlendirilmistir. Buna göre, iki yöntem arasında paralellik vardır ve en düsük stresler implant-implant baglantılı modellerde, en yüksek stresler ise disimplant destekli, semirijit baglantılı modellerde gözlemlenmistir. Dis-implant destekli modeller implant-implant destekli modeller ile yakın sonuçlar göstermislerdir. Buna baglı olarak implant-implant destekli sabit parsiyel protezlerin uygulanamadıgı yerlerde dis-implant destekli rijit baglantılı sabit parsiyel protezlerin bir alternatif olabilecegi söylenebilir.

Özet (Çeviri)

The aim of this study is to evaluate the effect of rigid/semi-rigid attachments in implant-tooth and implant-implant supported fixed partial dentures on the supporting bone with 2 different stress analysis methods. For this purpose 3 Straumann implants with 4,1mm in diameter, 12mm in lenght, solid, screw type and newly extracted caries free right upper second premolar tooth was used. Natural tooth was prepared in shoulder margin design with the angle of º6 at the top. The root surface was coated with silicone impression material 0,20-0,30 mm in thickness. Implants and natural tooth were placed in acrylic blocks 45mmx10mmx50mm and abutments with 50mm in height were fixed on implants. `T? type precise attachment was used at connector areas in metal ceramic fixed partial dentures. In photoelastic stress analysis method PL-2 epoxy resin was used. In order to see stress areas, white light and polariscope and for loading universal test device was used. The 300N was applied vertically in the centre of occlusal table for each sample and results were screened with digital camera. For finite element analysis computer aided models, all structures (enamel, dentine, pulp, periodontal ligament, bone, implant) were created as actual sizes regarding elasticity modulus and Poisson rates and SAP2000 software was used. Models were sectioned by two milimeters. All structures were assumed as homogen, linear elastic and isotropic. The samples were loaded and results were evaluated with von Misses scale. The results of two different stress analysis methods were evaluated comperatively and seperately. The results of, two methods finite element and photoelastic stres analysis were parallel and the lowest stress values were located in implant-implant supported models, the highest stress values were located in tooth-implant supported, semirigid attachments. Tooth-implant supported models showed similar results when compared to implant-implant supported models. When implant-implant supported fixed partial dentures could not be used, tooth-implant supported fixed partial dentures with rigid attachment could be an alternative.

Benzer Tezler

  1. Local and global modelling of semirigid structural connections using finite element models

    Yarı-rijit yapısal birleşimlerin lokal ve global sonlu eleman modelleri

    KEMAL BURAK HANOĞLU

    Yüksek Lisans

    İngilizce

    İngilizce

    1996

    İnşaat MühendisliğiBoğaziçi Üniversitesi

    PROF.DR. GÜLAY ALTAY

  2. Pes planuslu bireylerde farklı tip tabanlıkların elektromiyografik kas aktivasyonu üzerine etkisinin incelenmesi

    Investigation of the effect of insoles of different types on electromyographic muscle activation in individuals with pes planus

    EBRAR ERKAN

    Yüksek Lisans

    Türkçe

    Türkçe

    2023

    Fizyoterapi ve RehabilitasyonBolu Abant İzzet Baysal Üniversitesi

    Fizik Tedavi ve Rehabilitasyon Ana Bilim Dalı

    DOÇ. DR. TAMER ÇANKAYA

  3. Osteoporotik vertebra modelinde (poliüretan köpük blok) rijit rod (titanyum) ve semi rijit (polieter eter keton, PEEK) rod ile yapılan stabilizasyon sistemlerinin biyomekanik karşılaştırılması

    Biomechanical comparison of stabilization systems containing rigid rod (titanium) and semi rigid (polyeter eter keton, PEEK) rod in osteoporotic vertebrae model (polyurethane foam block)

    EGEMEN IŞITAN

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2018

    NöroşirürjiSağlık Bilimleri Üniversitesi

    Beyin ve Sinir Cerrahisi Ana Bilim Dalı

    DOÇ. DR. ALİ DALGIÇ

  4. Trikuspit onarımı: Sütur anuloplasti teknikleri ile rijit ve flexible ring anuloplasti tekniklerinin kısa ve uzun dönem sonuçları

    Tricuspit repair: Short and long-term results of suture anuloplasty techniques and rigid and flexible ring anuloplasty techniques

    UFUK TÜRKMEN

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2014

    Göğüs Kalp ve Damar CerrahisiSağlık Bakanlığı

    Kalp ve Damar Cerrahisi Ana Bilim Dalı

    DOÇ. DR. SADİ KAPLAN

  5. Koyun lomber omurgasında tek taraflı dinamik stabilizasyon uygulamasının biyomekanik incelemesi

    Biomechanical investigation of one sided dynamic stabilization in the lumbar spine of sheep

    DURMUŞ OĞUZ KARAKOYUN

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2013

    NöroşirürjiSağlık Bakanlığı

    Nöroşirürji Ana Bilim Dalı

    DOÇ. DR. ALİ DALGIÇ