Amperometric determination of ascorbic acid (vitamin C) by poly (vinylferrocene)-polypyrrole modified platinum electrode
Poli (vinilferrocen)-polipirol modifiye platin elektrodu ile askorbik asit (vitamin C) tayini
- Tez No: 197175
- Danışmanlar: PROF. DR. HALUK ÖZYÖRÜK
- Tez Türü: Yüksek Lisans
- Konular: Kimya, Chemistry
- Anahtar Kelimeler: Poli(vinilferrosenyum)-Polipirol modifiye elektrot, askorbikasit, amperometrik sensör, Poly(vinylferrocenium)-Polypyrrole modified electrode, ascorbic acid, amperometric sensor
- Yıl: 2005
- Dil: İngilizce
- Üniversite: Hacettepe Üniversitesi
- Enstitü: Fen Bilimleri Enstitüsü
- Ana Bilim Dalı: Kimya Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
Bu çalışmada, 2 mg mL-1 poli(vinilferrosen) ve 20 mM pirol içeren metilen klorür/0.1 M TBAP çözücü/destek elektrolit sisteminde Ag/AgCl elektroduna karşı0.0 - +1.1 V arasında dönüşümlü voltametrik tarama ile oluşturulan bir modifiyeelektrot kullanarak askorbik asit için kararlı hal amperometrik ölçümleri yapıldı.Tarama sırasında elektrot yüzeyinde pirol polimerleşirken, poli(vinilferrosenyum)polimer tabakası oluşturuldu.En uygun amperometrik ölçüm koşulları olarak; pH= 5.0, 5 mM fosfat tamponu,DKE'ye karşı +0.5 V sabit potansiyel, dönüşümlü voltametrik 10 döngü ile eldeedilen kaplama kalınlığı, 20ºC ortam sıcaklığı, 20 mM pirol derişimi bulundu.PVF+PPy+ polimer elektrot yapısı yüksek iletkenlik özelliğiyle katalitik etkilerinibirleştirmiştir.
Özet (Çeviri)
In this study the steady state amperometric measurements of ascorbic acid wasperformed by a modified Pt electrode. The modified electrode was developedthrough cyclic voltammetric scans between 0.0 to +1.1V vs. Ag/AgCl electrode inmethylene chloride/0.1 M tetra-n-butyl ammonium perchlorate solvent/supportingelectrolyte system which contains 2 mg mL-1 poly(vinylferrocene) and 20 mMpyrrole. While scanning pyrrole was electropolymerized and poly(vinylferrocenium)was electroprecipitated onto the electrode surface.The most suitable amperometric measurement conditions were found as 5 mMphosphate buffer at pH 5.0, +0.5 V vs. SCE constant applied potential, 10 cyclesof scanning as the polymeric film thickness and 20ºC as the temperature of themedium, concentration of pyrrole in the polymer solution as 20 mM.The higher conductivity and mediator effects are combined in the PVF+PPy+modified electrode structure.
Benzer Tezler
- Elektrokimyasal sensör materyali olarak polimerlerin sentezi ve fizikokimyasal özelliklerinin incelenmesi
Başlık çevirisi yok
ERGUN EKİNCİ
- Sulu ortamda glikoz tayini için yeni bir biyosensörün geliştirilmesi
Başlık çevirisi yok
PINAR ERDOĞDU
- Bazı yerli üzüm çeşitlerinde yaprağın ampelografik ölçülerinin belirlenmesi
Başlık çevirisi yok
MEHMET TAŞCI
- Bazı biyokimyasal moleküllerin iletken polimer elektrotlardaki voltametrik davranışlarının incelenmesi
Başlık çevirisi yok
GAMZE ERDOĞDU