Geri Dön

“Self tappıng”ve“Self drıllıng”vida sistemlerinin biyomekanik özelliklerinin tavşanda farklı yüz kemiklerinde karşılaştırılması

Comparing biomechanical properties of“Self tapping”and“Self drilling”screw systems on rabbit facial bones

  1. Tez No: 230149
  2. Yazar: MUSTAFA ONUR ÇUKURLUOĞLU
  3. Danışmanlar: DOÇ. DR. SELAHATTİN ÖZMEN
  4. Tez Türü: Tıpta Uzmanlık
  5. Konular: Plastik ve Rekonstrüktif Cerrahi, Plastic and Reconstructive Surgery
  6. Anahtar Kelimeler: Fiksasyon, Kemik ve kemikler, Kemik vidaları, Kırık fiksasyonu, Maksillofasiyal yaralanmalar, Tavşanlar, Fixation, Bone and bones, Bone screws, Fracture fixation, Maxillofacial injuries, Rabbits
  7. Yıl: 2009
  8. Dil: Türkçe
  9. Üniversite: Gazi Üniversitesi
  10. Enstitü: Tıp Fakültesi
  11. Ana Bilim Dalı: Plastik Rekonstrüktif ve Estetik Cerrahi Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Maksillofasiyal travma ve ortognatik cerrahi için, plak ve vida sistemleri ile açık redüksiyon ve internal fiksasyon günümüzde en sık tercih edilen yöntemdir. Ancak kullanılacak sistemlerle ilgili kesin endikasyonlar belirlenmemiştir. Bu çalışmanın amacı ?self drilling? ve ?self tapping? vidaların tavşanların farklı yüz kemiklerinde biyomekanik özelliklerini karşılaştırmaktırÇalışmada ağırlıkları 2800-3000 gr olan, 16 adet, erkek Yeni Zelanda tavşanı kullanıldı. Tüm deneklerde sol tarafa ?self drilling?, sağ tarafa ?self tapping? vida uygulandı. İki mm çaplı 7mm uzunlukta vidalar mandibulaya bikortikal olarak; 2mm çaplı 5mm uzunlukta vidalar mandibulaya monokortikal olarak, maksillaya ve orbita alt kenarına yerleştirildi. Deneklerden 8 tanesi hemen sakrifiye edildi, kalan diğer 8 tanesi ise 6 hafta iyileşme periyodu sonunda sakrifiye edildi. Vidaları kıyaslamak için giriş tork kuvvetleri ve aksiyel çekme testleri uygulandı. Her vida için kortikal kemik kalınlığı ölçümü yapıldı. İstatistiksel çalışma için bağımlı t testi ve Pearson korelasyon analizi kullanıldı. Kortikal kalınlık ortalamaları mandibula angulusta 630,74µm, mandibula ön kısmında 445,00µm, maksillada 275,05µm ve orbitada 335,25µm olarak bulundu. Hem 0. hafta hem altı hafta iyileşme süreci olan gruplarda tüm bölgeler için ?self drilling? vidaların aksiyel çekme kuvvetleri ?self tapping? vidalara göre daha yüksek bulundu. Ancak bu fark istatistiksel olarak anlamlı değildi. Tüm bölgelerde ?Self drilling? vidaların giriş tork kuvvetleri ?self tapping? vidalara göre daha yüksek bulundu. Mandibula bikortikal (p<0,001), mandibula monokortikal (p=0,002) ve orbitada (p=0,008) bu fark istatistiksel olarak anlamlı ancak maksilla (p=0,021) için anlamsız bulundu. Kemik iyileşmesinin etkisini araştırmak için 0. hafta ile 6. hafta denekler kıyaslandı. ?Self drilling? vidalar için 6. hafta grubunda her bölgede çekme kuvvetleri fazla bulunsa da fark istatistiksel olarak anlamlı değildi. ?Self tapping? vidalar için maksillada 6. hafta çekme kuvvetleri azalmış diğer bölgelerde artmış bulunsa da bu farklar istatistiksel olarak anlamlı değildi. Sıfırıncı hafta grubunda hem ?self tapping? hem ?self drilling? vidalar için mandibulada bikortikal yerleştirilenlerin çekme kuvvetleri monokortikal yerleştirilene göre istatistiksel olarak anlamlı olacak şekilde fazla bulundu. Altıncı hafta grubunda hem ?self tapping? hem ?self drilling? vidalar için mandibulada bikortikal yerleştirilenlerin çekme kuvvetleri monokortikal yerleştirilene göre fazla bulunsa da fark istatistiksel olarak anlamlı değildi. Tüm vidalar için bikortikal yerleştirilenlerin giriş tork kuvvetleri monokortikal yerleştirilene göre istatistiksel olarak anlamlı olacak şekilde fazla bulundu. Tüm vidalar için kortikal kemik kalınlığı ile hem çekme hem de giriş tork kuvvetleri arasında doğrusal ilişki olduğu gösterildiSonuç olarak ?self drilling? vidalar, termal hasar oluşturmaması, ameliyat süresini kısaltması, yeterli tutunma kuvveti sağlaması ve ince kemiklerde yerleştirme kolaylığı nedeniyle, maksilla ve orbita gibi ince yüz kemiklerinde avantajlı olabilirler.

Özet (Çeviri)

Nowadays, open reduction and internal fixation with plaque and screw systems is the most preferred system for maxillofacial traumatology and orthognathic surgery. Absolute indications about used systems are not mentioned. Purpose of this study is to compare biomechanic properties of ?self drilling? and ?self tapping? screws on rabbits different face bones.Sixteen New Zealand male weighting between 2800-3000 grams were used in this study. On all test subjects for the left side ?self drilling? and for the right side ?self tapping? screws are applied. Two mm diameter, 7 mm length screws were placed mandible bicortically, 2 mm diameter, 5 mm length screws were placed mandible monocortically, maxilla and orbita lower rim. 8 of the rabbits are sacrificed instantly and the rest 8 rabbits are sacrificed after the 6 week recovery period. To compare the screws initial torque forces and axial pull-out tests are applied. Cortical bone thickness measurements are done for each screw. Dependent sample t test and Pearson correlation analysis are used for the statistical study. Cortical thickness means are found as 630,74µm on mandible angle, 445,00µm on mandible front part, 275,05µm on maxilla and 335,25µm on orbita lower rim. For all areas in both 0. week and 6. week recovery period groups axial pull-out forces of ?self drilling? screws are found higher than ?self tapping? screws. But this difference was not statistically significant .On all areas initial torque forces of self drilling screws are found higher than self tapping screws. This difference was statistically significant for mandible bicortically (p<0,001), mandible monocortically (p=0,002), and orbita lower rim (p=0,008) but wasn?t for maxilla (p=0,021). 0. week and 6. week test subjects are compared for investigating bone recovery effect. For ?self drilling? screws in 6. week group on all areas pull-out forces are found higher but the difference was not statistically significant. For self tapping screws 6. week pull-out forces are found decreased on maxilla and increased on the other areas but the difference was not statistically significant. In 0. week group for both ?self tapping? and ?self drilling? screws pull-out forces of the screws that are placed on mandible bicortically are found higher than the monocortically placed screws and this difference was statistically significant. In 6. week group for both self tapping and self drilling screws pull-out forces of the screws that are placed on mandible bicortically are found higher than the monocortically placed screws but this difference was not statistically significant. For all screws initial torque forces of bicortically placed screws are found higher than the monocortically placed screws and this difference was statistically significant. For all screws a linear relationship between cortical bone thickness and both pull-out and initial torque forces was foundAs a result, it may be advantageous to use self drilling screws on thin face bones like maxilla and orbita as they don?t form thermal damage, decrease the surgery time, provide enough holding force and are easy to be placed on thin bones.

Benzer Tezler

  1. Sagittal split ramus osteotomisi sonrası farklı vida türlerinin biyomekanik dayanımının koyun mandibula modelinde değerlendirilmesi

    Evaluation of the biomechanical strength of different screw types after sagittal split ramus osteotomy using a sheep mandible model

    NUR MUHAMMED DEMİR

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2026

    Diş HekimliğiBolu Abant İzzet Baysal Üniversitesi

    Ağız, Diş ve Çene Cerrahisi Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ ÖMER FARUK BOYLU

  2. Self-tapping ve self-drilling ortodontik mikro implantların ortodontik tedavi sürecinde stabilitelerinin karşılaştırmalı değerlendirilmesi

    Comparative evaluation of the stability of self-tapping and self-drilling orthodontic micro implants during orthodontic treatment

    SİNA YILDIRIM

    Doktora

    Türkçe

    Türkçe

    2014

    Diş HekimliğiKaradeniz Teknik Üniversitesi

    Ortodonti Ana Bilim Dalı

    YRD. DOÇ. DR. MEHMET BİROL ÖZEL

  3. Kullanılmış ve kullanılmamış self-tapping, self-drilling mikro implantların stabilitelerinin ın vitro koşullarda karşılaştırılması

    In vitro comparison of the stability of reused self-tapping, self-drilling micro implants with unused ones

    BARIŞ BAŞER

    Diş Hekimliği Uzmanlık

    İngilizce

    İngilizce

    2018

    Diş HekimliğiKaradeniz Teknik Üniversitesi

    Ortodonti Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ MEHMET BİROL ÖZEL

  4. Ortodontik mikro-implantların primer stabilitesinin in vitro koşullarda incelenmesi

    The evaluation of the primary stability of the orthodontic micro-implants in vitro

    SEÇİL ÇEHRELİ

    Doktora

    Türkçe

    Türkçe

    2011

    Diş HekimliğiBaşkent Üniversitesi

    Ortodonti Ana Bilim Dalı

    DOÇ. DR. AYÇA ARMAN ÖZÇIRPICI

  5. Ark PVD yöntemiyle tin kaplanmış kesici takımların karakterizasyonu ve performanslarının incelenmesi

    Başlık çevirisi yok

    M.CENK TÜRKÜZ

    Yüksek Lisans

    Türkçe

    Türkçe

    1997

    Metalurji Mühendisliğiİstanbul Teknik Üniversitesi

    Metalurji Mühendisliği Ana Bilim Dalı

    PROF. DR. E. SABRİ KAYALI