Radyoterapi uygulamalarında LiF dozimetreleri kullanılarak doku eşdeğer ortamlardaki doz dağılımlarının incelenmesi

Investigation of dose distribution in tissue equivalent mediums in radiotherapy applications using LiF dosimeters

  1. Tez No: 256892
  2. Yazar: MELİS GÖKÇE
  3. Danışmanlar: DOÇ. DR. TURGAY KARALI
  4. Tez Türü: Doktora
  5. Konular: Fizik ve Fizik Mühendisliği, Physics and Physics Engineering
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2009
  8. Dil: Türkçe
  9. Üniversite: Ege Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Nükleer Bilimler Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 171

Özet

Medikal ışınlamaların optimizasyonunda temel unsurlardan biri radyasyon dozimetrisidir. Radyoterapide tümör dozu maksimum iken, normal dokuların radyasyondan kaynaklanan komplikasyonları kabul edilebilir seviyede tutulmalıdır. Teknolojideki gelişmeler ışınlama tekniklerinin gelişmesini sağlamış ve beraberinde daha karmaşık tedavi planlamaları ile daha düşük kabul edilebilir hata sınırları getirmiştir.Bu tezin amacı LiF:Mg,Ti termolüminesans dozimetreleri (TLD) ile çeşitli radyoterapi kaynaklarının, insan dokusunu simüle eden ortamlarda, çeşitli ışınlama koşulları altında doz dağılımlarının incelenmesidir. Bu kapsamda, ışınlamalar farklı geometrilerde tasarlanan balmumu, katı su ve polietilen fantomlar üzerinde gerçekleştirilmiştir.Katı su fantomunda Ir-192 (HDR) brakiterapi kaynağı ile yapılan ışınlamalarda kaynağın ışınlama pozisyonunda yapılan 3 mm'lik değişimin doz değerlerinde %25-30 oranında farklılığa sebep olduğu bulunmuştur. Bununla birlikte saçılmalardan dolayı, fantom hacminin elde edilen doz dağılımlarına etkisinin deneysel hata sınırları içinde yer aldığı sonucuna varılmıştır.Polietilen fantomda Ir-192 kaynağı ile ilk defa yakın mesafelerde deneysel olarak gerçekleştirilen ölçümler sonucunda ?x ekseninde daha yüksek doz değerlerinin elde edilmesi, Ir-192 kaynağının özellikle yakın geometrilerde daha belirgin hale gelen ve beklendiği gibi homojen olmayan doz dağılımına sahip olduğu sonucuna ulaşılmasını sağlamıştır.Co-60 kaynağı ile yapılan derinlik dozu, maksimum doz ve cilt dozu ışınlama, verilerinden 10 cm derinlik için yapılan ışınlamalarda alan kenarında ve alan dışında kalan noktalarda doz değerlerinin 5 cm derinlik için yapılan ölçümlerden daha yüksek olduğu saptanmıştır. Bunlara ek olarak 10 cm derinliğe 1 Gy ile yapılan ışınlamalarda elde edilen cilt dozu değerlerinin aynı koşullarda 5 cm derinlik için yapılan deneyden %40'lara varan değerlerde daha yüksek olduğu bulunmuştur. Bu tez kapsamında gerçekleştirilen in vivo çalışmalarında kullanılan ışınlama alanları için lens dozu değerleri ortalama olarak hedef dozun %10 ile %25'i arasında yer almaktadır. Elde edilen cilt dozları beklenen düzeylerde ve hedef organ dozunun yaklaşık olarak % 65'i kadardır.

Özet (Çeviri)

Radiation dosimetry is an essential part of optimization in medical exposures. In radiotherapy tumour dose shall be maximized and radiation-induced normal tissue complications kept acceptable. Computerization and technological developments have led to improved irradiation techniques which are accompanied by increasing complexity and less margin for error.The aim of this thesis was to investigate the dose distributions of various radiotherapy sources by LiF:Mg,Ti thermoluminescence dosimeters under different irradiation conditions in medium simulating the human tissue. In this context, irradiations were done on wax, solid water and polyethylene phantom materials designed at different geometries.For the irradiations in solid water phantom by Ir-192 (HDR) brachytherapy source it was found that 3 mm alteration in the position of the source could cause a difference of 25-30% at the dose levels. Besides, the effect of phantom dimensions on the dose distributions due to scattering lay in the experimental uncertainty so it is concluded that the phantom dimensions does not make considerable influence on the results obtained with TLD-100 due to scattering effect. For the irradiations with Ir-192 source conducted on polyethylene phantom at close distances which have not been encountered in the literature before, higher dose levels occurred in the ?x axis yield to the results that the dose distribution of Ir-192 source has inhomogeneous feature which is not expected, and becomes more significant at short distances.Depth dose, maximum dose and skin dose irradiations were performed on solid water. According to the results it is confirmed that the dose values are higher for the points on the field edge and out of the field for the irradiations done for 10 cm depth. Besides skin dose values for the irradiations done for 10 cm depth are higher up to 40% than the dose values obtained by the irradiations for 5 cm depth.From the conducted in vivo studies the average lens dose values were found between %10 and %25 of target doses for the irradiation fields used in this study. The skin doses obtained in this study are about 65% of target doses and lay in the allowable dose levels.

Benzer Tezler

  1. Radyoterapi uygulamalarında termolüminesans dozimetreler ile doz dağılımlarının incelenmesi

    Research of dose distribution by thermoluminescence dosimetries in radiotherapy applications

    ZEYNEP AÇELYA DALCALI

    Yüksek Lisans

    Türkçe

    Türkçe

    2016

    Fizik ve Fizik MühendisliğiKırklareli Üniversitesi

    Fizik Ana Bilim Dalı

    DOÇ. DR. SERPİL AKÖZCAN

  2. Radyoterapide termolüminesans dozimetre ve yarı iletken diyot dozimetre sistemi kullanılarak yüzey dozlarının karşılaştırılması

    Comparing surface doses using thermoluminance dosimerty and semi conductor diodes system in radiotherapy

    EDA KAYA

    Yüksek Lisans

    Türkçe

    Türkçe

    2010

    Fizik ve Fizik MühendisliğiErciyes Üniversitesi

    Radyasyon Onkolojisi Ana Bilim Dalı

    DOÇ. DR. SERDAR SOYER

  3. Amorf silikon yapıdaki Yapıdaki Elektronik Portal Görüntüleme Cihazının (EPID) rutin kalite kontrol testlerde, cihaz kabul testlerinde ve yoğunluk ayarlı radyoterapi tekniği Çok Yapraklı Kolimatör (ÇYK) testlerinde film yerine kullanılabilirliliği

    The usability of amorphous silicon Electronic Portal Imaging Device (EPID) in routine quality control tests, acceptance tests and Multi-Leaf Collimator (MLC) tests for intensity modulated radiotherapy instead of film

    DENİZ ÇELİK

    Yüksek Lisans

    Türkçe

    Türkçe

    2011

    OnkolojiHacettepe Üniversitesi

    Radyasyon Onkolojisi Ana Bilim Dalı

    PROF. DR. FERAH YILDIZ

  4. Radyoterapide kullanılan koruyucu bloklar ile kurşun bilye ilaveli koruyucu blokların gama ışını geçirgenliklerinin karşılaştırılması

    The comparison of gamma ray transmissions of shielding blocks with lead marbles and shielding blocks used in radiotherapy

    NURAY YAVUZKANAT

    Yüksek Lisans

    Türkçe

    Türkçe

    2010

    Fizik ve Fizik MühendisliğiAnkara Üniversitesi

    Fizik Ana Bilim Dalı

    PROF. DR. AYŞE KAŞKAŞ

  5. Radyoterapi uygulamalarında olasılıksal risk analizi

    Probabilistic risk analysis of radiotherapy application

    ÇAĞATAY RECEP ÖZBAY

    Doktora

    Türkçe

    Türkçe

    2018

    Fizik ve Fizik MühendisliğiEge Üniversitesi

    Nükleer Bilimler Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ MEHMET BAYBURT