Pediatrik olgularda el otorefraktometresinin (plusoptix a09) kırma kusurlarının belirlenmesindeki yeri ve güvenilirliği

Clinical use and reliability of hand-held autorefractometer (plusoptix a09) for the measurement of refractive errors in pediatric subjects

  1. Tez No: 297402
  2. Yazar: AYŞE ÖZPINAR
  3. Danışmanlar: PROF. DR. NAZMİ ZENGİN
  4. Tez Türü: Tıpta Uzmanlık
  5. Konular: Göz Hastalıkları, Eye Diseases
  6. Anahtar Kelimeler: Akomodasyon, fotorefraktör, refraksiyon kusurları, Göz uyumu, Pediatri, Refraksiyon-oküler, Refraktif kusurlar, Refraktometri, Tıbbi araç-gereç ve donanımlar, Accommodation, photorefractor, refraction errors, Accommodation-ocular, Pediatrics, Refraction-ocular, Refractive errors, Refractometry, Equipment and supplies
  7. Yıl: 2011
  8. Dil: Türkçe
  9. Üniversite: Selçuk Üniversitesi
  10. Enstitü: Meram Tıp Fakültesi
  11. Ana Bilim Dalı: Göz Hastalıkları Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Amaç: Pediatrik olgularda el otorefraktometresinin (Plusoptix A09®) kırma kusurlarının belirlenmesindeki yeri ve güvenilirliğini saptamakGereç ve Yöntem: Çalışmaya kırma kusuru ve şaşılık dışında ek göz hastalığı olmayan 91 çocuğun 182 gözü, olguların dosyaları retrospektif olarak incelenerek dahil edildi. Kırma kusuru hem fotorefraktör (Plusoptix A09®) hem de otorefraktometre (Topcon KR8100®) ile sikloplejisiz ve sikloplejili ölçüldü. Her iki cihazla elde edilen sferik, silindirik güç, silindirik aks ve sferik ekivalan değerleri istatistiksel olarak karşılaştırıldı.Bulgular: Olguların ortalama yaşı 5.5 ± 2.63 (6 ay-10 yıl) yıl idi. Siklopleji öncesi sferik ve silindirik güç ortanca değeri fotorefraktör ile +1.42 D ve -0.83 D, OR ile +0.71 D ve -0.75 D idi. Siklopleji sonrası sferik ve silindirik güç ortanca değeri fotorefraktör ile +1.83 D ve -0.79 D, OR ile +1.08 D ve -0.67 D idi. Siklopleji öncesi ve sonrası her iki cihaz ile sferik ve silindirik güçler arasında istatistiksel olarak anlamlı fark bulunurken (P<0.05) silindirik akslarda belirgin fark yoktu.Sonuç: Siklopleji öncesi fotorefraktörde cihaza bağlı akomodasyon refleksi daha az görülürken otorefraktometre yakın mesafeden ölçüm yaptığı için ölçümlerinde miyopiye kayma daha fazla görüldü. Siklopleji sonrası OR değerlerinin sikloplejisiz fotorektör değerlerinden daha hipermetropik olduğu görüldü. Bu bulgularla pediatrik olgularda akomodasyon nedeniyle sikloplejisiz fotorefraktör ölçümleri yüksek hipermetropiyi saptamada yetersiz kalabilir. Ancak 1 m mesafeden damlasız binoküler ve kısa sürede ölçüm alabilmesi nedeniyle toplumda göz taramalarında tercih edilebilir.

Özet (Çeviri)

Purpose: The aim of this study is to confirm the clinical use and reliability of hand-held autoreftactometer (Plusoptix A098®) for the measurement of refractive errors in pediatric subjects.Material and Method: One hundred eighty two eyes of 91 children who did not have ocular pathology apart from refractive error and strabismus were included in the study by retrospectively analyzing the patient records. The refractive errors were measured with and without cycloplegia by using photorefractor (Plusoptix A09®) and autorefractometer (Topcon KR8100®). The measurements of spherical and cylindrical power, cylindrical axis and spherical equivalant obtained by the two devices were statistically compared.Results: Mean age of patients was 5.5 ± 2.6 years (range 6 month-10 years). Mean spheric power (SP) and cylindric power (CP) before cycloplegia were +1.42 D and -0.83 D with photorefractor, +0.71 D and -0.75 D with autorefractometer. Mean SP and CP after cycloplegia were +1.83 D and -0.79 D with photorefractor, +1.08 D and -0.67 D with autorefractometer. The differences in SP and CP measured by the two devices before and after cycloplegia were found statistically significant (P<0.05), however there was no significant difference in cylindric axis.Conclusions: While accomodation reflex caused by the device was less common with photorefractor before cycloplegia, because of its close-range measurements, myopic shift was most seen with autorefractometer. Autorefractometer measurements with cycloplegia were more hypermetropic than photorefractor measurements without cycloplegia. With these findings, photorefractor may be inadequate for identification of high hypermetropia in pediatric cases because of accomodation. However it may be preferred for screening because it provides binocular measurements from 1 m distance without eye drops in a short period.

Benzer Tezler

  1. Pediatrik olgularda premedikasyon yöntemlerinin preoperatif ve postoperatif anksiyete üzerine etkinliğinin incelenmesi

    Evaluation the efficacy of premedication methods on preoperative and postoperative anxiety in pediatric patients

    MEHMET BURAK EŞKİN

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2009

    Anestezi ve ReanimasyonGata

    Anesteziyoloji ve Reanimasyon Ana Bilim Dalı

    DOÇ. DR. MEHMET EMİN ORHAN

  2. 12 Yaş ve üstü pediatrik yaş grubunda kemik yaşı tayini için çekilen el bileği grafisinde kullanılan Greulich-Pyle ve Tanner-Whitehouse yöntemlerinin karşılaştırılması

    A comparison of 12 years and above used in wrist radiographs taken for determination of bone age in the pediatric age group Greulich-Pyle and Tanner-Whitehouse method

    ATİLLA KAPLAN

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2014

    Radyoloji ve Nükleer Tıpİstanbul Üniversitesi

    Radyodiagnostik Ana Bilim Dalı

    PROF. DR. ENSAR YEKELER

  3. Cerrahi tedavi uygulanan pediatrik medial epikondil kırıklarının postoperatif sonuçları

    Postoperative outcomes of pediatric medial epicondyle fractures treated surgically

    ALİ EMRE AKIN

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2025

    Ortopedi ve TravmatolojiManisa Celal Bayar Üniversitesi

    Ortopedi ve Travmatoloji Ana Bilim Dalı

    PROF. DR. GÜVENİR OKCU

  4. Pediatrik anestezide supraglottik havayolu araçlarının gastrik insüflasyon açısından ultrason kullanılarak karşılaştırılması

    Ultrasonographic comparison of supraglottic airway devices regarding gastric insufflation in paediatric anaesthesia

    MERT CAN UĞURCAN

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2026

    Anestezi ve ReanimasyonSağlık Bilimleri Üniversitesi

    Anesteziyoloji ve Reanimasyon Ana Bilim Dalı

    DOÇ. DR. NEVZAT MEHMET MUTLU

  5. Pediatrik olgulara 1996-2017 yılları arasında uygulanan yama testi sonuçlarının değerlendirilmesi

    Evaluation of the patch test results in pediatric patients between 1996-2017

    ZEYNEP YILMAZ

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2019

    Dermatolojiİstanbul Üniversitesi

    Deri ve Zührevi Hastalıklar Ana Bilim Dalı

    PROF. DR. ESEN ÖZKAYA