Bitişik alan IMRT planlamasında iki farklı kolimatör ( x ve y ) yönünün birleşim bölgesindeki doz dağılımına etkisinin araştırılması

The investigation of the effects of two different collimator direction (X and Y) on conjunction region dose distribution in adjacent fields IMRT planning.

  1. Tez No: 302672
  2. Yazar: AYDIN ÇAKIR
  3. Danışmanlar: PROF. DR. HATİCE BİLGE
  4. Tez Türü: Doktora
  5. Konular: Onkoloji, Oncology
  6. Anahtar Kelimeler: Baş boyun IMRT, double focus MLC, kolimator hatası, PTW 2D Array, penumbra, Kafa ve boyun neoplazmları, Kolimatör sistemleri, Neoplazmlar, Radyasyon, Radyasyon dozajı, Radyometri, Radyoterapi, Radyoterapi-bilgisayar yardımlı, Head neck IMRT, double focus MLC, collimator error, PTW 2D Array, penumbra, Head and neck neoplasms, Collimator systems, Neoplasms, Radiation, Radiation dosage, Radiometry, Radiotherapy, Radiotherapy-computer assisted
  7. Yıl: 2010
  8. Dil: Türkçe
  9. Üniversite: İstanbul Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Temel Onkoloji Ana Bilim Dalı
  12. Bilim Dalı: Tıbbi Radyofizik Bilim Dalı
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Double focus özelliğine sahip ONCOR(Siemens,Concord-USA) lineer hızlandırıcısının X ve Y kolimatörlerinin alan kenarındaki doz düşüş miktarlarının farklı olması bitişik ortogonal alanların kullanıldığı tedavilerde birleşim bölgesindeki doz dağılımını belirler. Bu durum hazırlanan plan ile hastada gerçekleşen plan arasında farklılıklara neden olabilir.Bu çalışmada, bitişik ortogonal alan kullanılarak yapılan konvansiyonel ve IMRT ışınlamalarında, X ve Y kolimatörlerinin alan birleşim kenarında kullanılmasının doz dağılımı üzerindeki etkisi araştırıldı.Bunun için kliniğimizde var olan ONCOR cihazına ait, X ve Y profil bilgileriyle iki ayrı cihaz modellendi. 20 baş boyun hastasının IMRT plan verifikasyonu PTW 2D Array Seven 29 ve GafChromic film ile yapıldı.Elde edilen veriler değerlendirildiğinde, X kolimatörü bitişik alan alarak kullanıldığında kolimatör sisteminin pozisyon doğruluğu ±1mm olduğunda doz homojenitesi -%5 ile +%6 arasında olduğu görüldü.Y kolimatörünün bitişik alan olarak kullanıldığı durumda ±1mm hatanın doz homojenetesini -%1,5 ile +%3,5 arasında değiştirdiği görüldü. Y kolimatörü kullanıldığında ±1mm kolimatör yerleştirme hatası tolere edilebilmektedir.Doz modellemede kullanılan kolimatör eksenlerinin tedavide kullanılması gerekmektedir. Kolimatör hatalarının tolere edilebilmesinde penumbranın daha geniş olduğu eksenin bitişik alan kenarında kullanılması birleşim bölgesindeki doz homojenitesi açısından yararlıdır.

Özet (Çeviri)

ONCOR (Siemens, Concord-USA) linear accelerator has double focus property, the difference in magnitude of dose reduction at X and Y collimator field edges of LINAC determines dose distribution in conjunction region when adjacent orthogonal fields is used for treatment. This situation causes a difference between prepared plan and actual plan.In this study, for conventional and IMRT irradiation including adjacent orthogonal fields, the effects of X and Y collimators on dose distribution on field junction edges were investigated. For this reason, two different machines, one of which was based on X profile and the other was based on Y profile, were modelled for ONCOR used in our clinics. The dosimetric verification of IMRT plans for 20 head neck patients were performed. Verification of fluence map were made using PTW 2D Array Seven 29 and Gafchromic EBT film.After the evaluation of datas obtained when X collimator was used for adjacent fields and position accuracy of collimator system was within ±1mm, dose homogenity was found between -5% and +6%. On the other hand when Y collimator was used for adjacent field, ±1mm error caused to change dose homogenity between -1.5% and +3.5%. As a result, when Y collimator was used, ±1mm collimator placement error was tolerated.Collimator axes used in dose modelling should be used for treatment. In order to tolerate collimator error, axis with wider penumbra should be used in adjacent field edges for better dose homogenity.

Benzer Tezler

  1. Baş-boyun bölgesi kanserlerinde yarım demet bitişik alan doz dağılımlarının film dozimetrisi ve bilgisayarlı planlama sistemi ile değerlendirilmesi

    Evaluation of the dose distribution of half-beam abutted fields in head and neck cancer by film dosimeter and computer based planning system

    MURAT KÖYLÜ

    Yüksek Lisans

    Türkçe

    Türkçe

    2006

    Fizik ve Fizik MühendisliğiEge Üniversitesi

    Radyasyon Onkolojisi Ana Bilim Dalı

    DOÇ. DR. DENİZ YALMAN

    ÖĞR. GÖR. NEZAHAT OLACAK

  2. Farklı enerjilerde elektron-elektron ve foton-elektron ışınlamalarında bitişik alan doz dağılımlarının değerlendirilmesi

    Evaluation of the dose distiributions of appositional fields at the different energies for electron-electron and photon-electron irradiations

    AYTÜL KANAT

    Yüksek Lisans

    Türkçe

    Türkçe

    2010

    OnkolojiAnkara Üniversitesi

    Medikal Fizik Ana Bilim Dalı

    DOÇ. DR. BAHAR DİRİCAN

  3. Bitişik betonarme binalar arasında oluşabilecek sismik etkileri önleyecek derz mesafesinin araştırılması

    Investigation of the separation distance for preventing seismic effects on reinforced concrete buildings

    TOLUNAY İBRAHİMAĞAOĞLU

    Yüksek Lisans

    Türkçe

    Türkçe

    2022

    Mühendislik Bilimleriİstanbul Teknik Üniversitesi

    Deprem Mühendisliği Ana Bilim Dalı

    DOÇ. DR. ARCAN YANIK

  4. Bitişik nizam yapılarda ankrajlı fore kazık uygulaması ve sayısal analizlerinin yapılması

    Design and numerical analysis of anchored bored pile systems in adjacent buildings

    MERTCAN YAKUT

    Yüksek Lisans

    Türkçe

    Türkçe

    2026

    İnşaat MühendisliğiOndokuz Mayıs Üniversitesi

    İnşaat Mühendisliği Ana Bilim Dalı

    DOÇ. DR. MUSTAFA VEKLİ

  5. Bitişik nizam yapıların dinamik etkilerinin viskoz sönümleyiciler tarafından sönümlenmesi

    Damping of the dynamic effects of adjacent structures by viscous dampers

    UĞUR YILDIRIM

    Yüksek Lisans

    Türkçe

    Türkçe

    2019

    İnşaat MühendisliğiManisa Celal Bayar Üniversitesi

    İnşaat Mühendisliği Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ HALİL NOHUTCU