Bitişik alan IMRT planlamasında iki farklı kolimatör ( x ve y ) yönünün birleşim bölgesindeki doz dağılımına etkisinin araştırılması
The investigation of the effects of two different collimator direction (X and Y) on conjunction region dose distribution in adjacent fields IMRT planning.
- Tez No: 302672
- Danışmanlar: PROF. DR. HATİCE BİLGE
- Tez Türü: Doktora
- Konular: Onkoloji, Oncology
- Anahtar Kelimeler: Baş boyun IMRT, double focus MLC, kolimator hatası, PTW 2D Array, penumbra, Head neck IMRT, double focus MLC, collimator error, PTW 2D Array, penumbra
- Yıl: 2010
- Dil: Türkçe
- Üniversite: İstanbul Üniversitesi
- Enstitü: Sağlık Bilimleri Enstitüsü
- Ana Bilim Dalı: Temel Onkoloji Ana Bilim Dalı
- Bilim Dalı: Tıbbi Radyofizik Bilim Dalı
- Sayfa Sayısı: 116
Özet
Double focus özelliğine sahip ONCOR(Siemens,Concord-USA) lineer hızlandırıcısının X ve Y kolimatörlerinin alan kenarındaki doz düşüş miktarlarının farklı olması bitişik ortogonal alanların kullanıldığı tedavilerde birleşim bölgesindeki doz dağılımını belirler. Bu durum hazırlanan plan ile hastada gerçekleşen plan arasında farklılıklara neden olabilir.Bu çalışmada, bitişik ortogonal alan kullanılarak yapılan konvansiyonel ve IMRT ışınlamalarında, X ve Y kolimatörlerinin alan birleşim kenarında kullanılmasının doz dağılımı üzerindeki etkisi araştırıldı.Bunun için kliniğimizde var olan ONCOR cihazına ait, X ve Y profil bilgileriyle iki ayrı cihaz modellendi. 20 baş boyun hastasının IMRT plan verifikasyonu PTW 2D Array Seven 29 ve GafChromic film ile yapıldı.Elde edilen veriler değerlendirildiğinde, X kolimatörü bitişik alan alarak kullanıldığında kolimatör sisteminin pozisyon doğruluğu ±1mm olduğunda doz homojenitesi -%5 ile +%6 arasında olduğu görüldü.Y kolimatörünün bitişik alan olarak kullanıldığı durumda ±1mm hatanın doz homojenetesini -%1,5 ile +%3,5 arasında değiştirdiği görüldü. Y kolimatörü kullanıldığında ±1mm kolimatör yerleştirme hatası tolere edilebilmektedir.Doz modellemede kullanılan kolimatör eksenlerinin tedavide kullanılması gerekmektedir. Kolimatör hatalarının tolere edilebilmesinde penumbranın daha geniş olduğu eksenin bitişik alan kenarında kullanılması birleşim bölgesindeki doz homojenitesi açısından yararlıdır.
Özet (Çeviri)
ONCOR (Siemens, Concord-USA) linear accelerator has double focus property, the difference in magnitude of dose reduction at X and Y collimator field edges of LINAC determines dose distribution in conjunction region when adjacent orthogonal fields is used for treatment. This situation causes a difference between prepared plan and actual plan.In this study, for conventional and IMRT irradiation including adjacent orthogonal fields, the effects of X and Y collimators on dose distribution on field junction edges were investigated. For this reason, two different machines, one of which was based on X profile and the other was based on Y profile, were modelled for ONCOR used in our clinics. The dosimetric verification of IMRT plans for 20 head neck patients were performed. Verification of fluence map were made using PTW 2D Array Seven 29 and Gafchromic EBT film.After the evaluation of datas obtained when X collimator was used for adjacent fields and position accuracy of collimator system was within ±1mm, dose homogenity was found between -5% and +6%. On the other hand when Y collimator was used for adjacent field, ±1mm error caused to change dose homogenity between -1.5% and +3.5%. As a result, when Y collimator was used, ±1mm collimator placement error was tolerated.Collimator axes used in dose modelling should be used for treatment. In order to tolerate collimator error, axis with wider penumbra should be used in adjacent field edges for better dose homogenity.
Benzer Tezler
- Baş-boyun bölgesi kanserlerinde yarım demet bitişik alan doz dağılımlarının film dozimetrisi ve bilgisayarlı planlama sistemi ile değerlendirilmesi
Evaluation of the dose distribution of half-beam abutted fields in head and neck cancer by film dosimeter and computer based planning system
MURAT KÖYLÜ
Yüksek Lisans
Türkçe
2006
Fizik ve Fizik MühendisliğiEge ÜniversitesiRadyasyon Onkolojisi Ana Bilim Dalı
DOÇ. DR. DENİZ YALMAN
ÖĞR. GÖR. NEZAHAT OLACAK
- Farklı enerjilerde elektron-elektron ve foton-elektron ışınlamalarında bitişik alan doz dağılımlarının değerlendirilmesi
Evaluation of the dose distiributions of appositional fields at the different energies for electron-electron and photon-electron irradiations
AYTÜL KANAT
Yüksek Lisans
Türkçe
2010
OnkolojiAnkara ÜniversitesiMedikal Fizik Ana Bilim Dalı
DOÇ. DR. BAHAR DİRİCAN
- Tüm vücut cildinin 6 MeV elektron demeti ile ışınlanmasında sabit huzme-hareketli masa tekniğinin uygulanabilirliği ve dozimetrisinin araştırılması
Total body skin irradiation with 6 MeV electron beam-applicability of fix beam and moving table with dozimetric investigation
SALİH GÜRDALLI
- Rhodobacter capsulatus bakterisinde Sitokrom C oksidaz biyogenesiz'inde rol alan genlerin belirlenmesi ve fonksiyonlarının tanımlanması
Identification of genes involved in biogenesis of Cytochrome C oxidase from rhodobacter capsulatus and determination of their functions
SEMRA AYGÜN SUNAR
Doktora
Türkçe
2006
BiyokimyaUludağ ÜniversitesiBiyoloji Ana Bilim Dalı
DOÇ. DR. SEVNUR MANDACI
PROF. DR. RAHMİ BİLALOĞLU
- ComCoS: An enhanced cache partitioning technique for integrated modular avionics
ComCoS: Entegre modüler aviyonikler için gelişmiş bir önbellek bölümleme tekniği
YAKUP HÜNER
Yüksek Lisans
İngilizce
2023
Bilgisayar Mühendisliği Bilimleri-Bilgisayar ve Kontrolİstanbul Teknik ÜniversitesiSavunma Teknolojileri Ana Bilim Dalı
DR. ÖĞR. ÜYESİ RAMAZAN YENİÇERİ