Geri Dön

Dental implant uygulanmış hastalarda enflamatuar sitokin düzeyleri ile plazma titanyum seviyesi arasındaki ilişkinin değerlendirilmesi

To evaluate relationship between inflamatuar citokin and plasma titanium level in dental implant treated patient

  1. Tez No: 304414
  2. Yazar: SÜLEYMAN KILIÇ
  3. Danışmanlar: PROF. DR. GÜLSÜM AK
  4. Tez Türü: Doktora
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2011
  8. Dil: Türkçe
  9. Üniversite: İstanbul Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Ağız, Diş, Çene Hastalıkları ve Cerrahisi Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 116

Özet

Biyouyumlu ve inert bir materyal olan Titanyum(Ti), biomedikal uygulamaların yapıldığı diş hekimliği ve ortopedi gibi alanlarda sıklıkla kullanılmakla birlikte, son zamanlarda Ti biyouyumluluğu hakkında olumsuz düşünceler ileri sürülmektedir. Ti ve alaşımlarının korozyona uğraması ve oluşan korozyon ürünlerinin kandaki ve dokulardaki seviyeleri günümüzde tartışılmakla birlikte farklı enflamatuar mediatörlerin implant korozyonu üzerine etkisi tam olarak araştırılmamıştır. Aynı zamanda enflamatuar mediatörlerin implant biyouyumluluğu ve osseointegrasyonda kritik rol oynadığı bilinmektedir. Bu çalışmada Ti implantların kandaki krozyon değerleri ve inflamatör mediatörlerin Ti implantların fiziksel korozyonu üzerine etkilerini belirlemek için kanda IL-1Beta, IL-6, IL-10 and TNF-Alfa sitokinlerinin düzeyleri ölçülmüştür. Araştırmaya çalışma için uygun kriterlere sahip 40 hasta dahil edilmiştir.Toplamda 127 adet implant uygulamasında, Zimmer ve İmplant Direct implantları kullanılmıştır (86 adet Zimmer, 41 adet İmplant Direct). Serum Ti seviyesi Thermo Elemental X Series ICP-MS cihazında tesbit edilmiştir. Serum IL-1Beta, IL-6, IL-10 ve TNF-Alfa seviyeleri ELİSA testi ile ölçülmüştür. İstatistiksel analizler; Student t, Mann Whitney U, Paired Sample, Pearson Spearman's rho testleri ile yapılmıştır. Araştırma sonuçlarına göre serum Ti seviyesi, implant uygulanmasından 4 ay sonraki ölçümlerde, implant uygulamasından önceki ölçümlere göre daha yüksek, fakat istatistiksel olarak anlamlı bulunmamıştır. Ayrıca IL-1Beta seviyesi 4 ay sonraki kontrol örneklerin de başlangıç seviyesine göre anlamlı şekilde yüksek tespit edilmiştir. Bayanlarda IL-1Beta seviyelerindeki artış istatiksel olarak anlamlı bulunmuştur. Çalışma sonuçlarına göre titanyum korozyonu kanda oluşmaktadır. Ancak titanyum korozyon ürünlerinin sıklıkla dokularda biriktiği göz önüne alınarak bu bulgu doku deneyleriyle de desteklenmelidir.

Özet (Çeviri)

Titanium has long been regarded as an inert and biocompatible metal, ideal for biomedical applications such as dental implants or joint replacements. However, concerns about the biocompatibility of Ti have lately arisen.Unfortunately information on reliable Ti baseline physiological levels in blood and organ tissues is still pending and corrosion of Ti or Ti alloys implants is controversial so far. Also inflammatory mediators on implant corrosion are not well studied; yet these effects are critical to implant biocompatibility and osseointegrration. In the current study the corrosion properties of titanium implants were studied in blood and IL-1Beta, IL-6, IL-10 and TNFAlfa secretion was measured to assess the affect of physilogical corrosion on Ti implants.40 voluntery patients and appropriated for the study were enrolled in the study. A total of 127 implants provided by Zimmer and Implant direct implant were applied.Thermo Elemental X Series ICP-MS has been used to establish Ti basal levels in blood. Also serum IL-1Beta, IL-6, IL-10 and TNF Alfa levels were measured by ELISA. In our analysis, Student t, Mann Whitney U, Paired Sample, Pearson, Spearman?s rho tests were used. Results showed that although Ti content in blood was higher than previously determined Ti levels, there was no statistically significant difference between Ti levels. IL-1beta levels significantly increased after 4 month of treatment. Also IL-1beta levels were statistically significant in women.The results indicate that corrosion from Ti implants occurs in the absence of wear in blood. However; titanium corrosion products usually accumulate on tissue because of that further experiment should focus on tissue accumulation.

Benzer Tezler

  1. Mekanik tedavi ve diyot lazer uygulanmış peri-implantitisli hastalarda peri-implant sulkus sıvısı periostin ve K vitamini seviyesi

    Periostin and vitamin K level of peri implant sulcus fluid in patients with peri-implantitis whom was administered with mechanical therapy and diode laser

    NEZAKET GARDENYA ÇEVİK ÜNALAN

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2021

    Diş HekimliğiKırıkkale Üniversitesi

    Periodontoloji Ana Bilim Dalı

    PROF. DR. HATİCE EBRU OLGUN

  2. Kronik periodontitisli hastalarda başlangıç periodontal tedavi ile birlikte kombine antibiyotik kullanımın diyare sıklığı ve klinik parametreler üzerine etkisi

    Initial periodontal treatment combined with the use of antibiotics; in chronic periodontitis patients, the effects of frequency of diarrhea and clinic parametres

    MİNE İDİL BALTALI

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2015

    Diş HekimliğiÇukurova Üniversitesi

    Periodontoloji Ana Bilim Dalı

    PROF. DR. MEHMET CENK HAYTAÇ

  3. Sinüs tabanı yükseltme ve implant uygulamaları sonrası maksiller sinüs bulgularının dental volumetrik tomografi ile değerlendirilmesi

    The evaluation of sinus findings of maxillary sinus with dental volumetric tomography after sinus floor elevation and implant

    HAZAL KARSLIOĞLU

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2017

    Diş HekimliğiOndokuz Mayıs Üniversitesi

    Ağız, Diş ve Çene Radyolojisi Ana Bilim Dalı

    PROF. DR. AYŞE PINAR SUMER

  4. Maksilla posterior bölgede yapılan dental implantların maksiler sinüs ve dentoalveolar yapılar üzerindeki etkilerinin CBCT ile preop ve postop olarak değerlendirilmesi

    Evaluation of the effects of dental implants made on Maxillary posterior region on maxillary sinus and dentoalveolar structures as preop and postop with CBCT

    NEBİHA HİLAL BİLGE

    Doktora

    Türkçe

    Türkçe

    2019

    Diş HekimliğiAtatürk Üniversitesi

    Ağız, Diş ve Çene Radyolojisi Ana Bilim Dalı

    PROF. DR. SAADETTİN DAĞİSTAN

  5. Dental implant uygulanan hastaların saç, tırnaklarında dental implantın içerdiği metallerin değerlendirilmesi

    Evaluation of metals contained in the dental implant in the hair and nail of dental implant patients

    BAHADIR SANCAR

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2017

    Diş HekimliğiAtatürk Üniversitesi

    Ağız Diş ve Çene Cerrahisi Ana Bilim Dalı

    PROF. DR. ERTUNÇ DAYI