Geri Dön

Farklı dayanak sistemlerinin implant-dayanak ara yüzeyindeki bakteriyel sızıntıya olan etkilerinin karşılaştırılması

Comparison of 3 different implant-abutment junction types on bacterial microleakage and flora.department of prosthodontics doctorate programme

  1. Tez No: 311458
  2. Yazar: GÜRKAN ERENEL
  3. Danışmanlar: DOÇ. DR. OSMAN CUMHUR SİPAHİ
  4. Tez Türü: Doktora
  5. Konular: Diş Hekimliği, Mikrobiyoloji, Dentistry, Microbiology
  6. Anahtar Kelimeler: Bakteriler, DNA, Dental implantasyon, Dental implantlar, Dental sızma, Protezler ve implantlar, Bacteria, DNA, Dental implantation, Dental implants, Dental leakage, Prostheses and implants
  7. Yıl: 2011
  8. Dil: Türkçe
  9. Üniversite: Gata
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Bu çalışmada; farklı dayanak bağlantısına sahip 3 tip implantın, implant-dayanak ara yüzeylerinde meydana gelen bakteriyel sızıntının ağız içi koşullarında (in-situ) örneklenmesi ve değerlerin karşılaştırılması amaçlanmıştır.Çalışmada toplam 30 hastaya yerleştirilen 3 farklı bağlantı tipine sahip implantın (10 adet paralel internal altıgen, 10 adet 11° açılı internaltrilob, 10 adet 1.5° açılı soğuk kaynak), implant içi boşluklarından fonksiyonel yükleme öncesi ve yükleme yapıldıktan 15 gün sonrasında mikrobiyal örnekler alındı. İmplanta komşu doğal dişeti cebinden alınan örnekler kontrol grubunu oluşturdu. Elde edilen örnekler mikrobiyoloji laboratuarında ?DNA Ekstraksiyon? işlemine tabi tutularak, bakteriyel DNA'lar elde edildi. Elde edilen DNA'lar PCR (polymerasechainreaction) ile amplifiye edildi ve micro-IDent®(Hain Diagnostics, LLC 3327 W. WadleySte. #3-361 Midland, TX 79707) şeritleri ile bakteri tanımlama işlemi yapıldı.Çalışmanın sonucunda incelenen ara-yüzeyler arasında istatistiksel olarak anlamlı farklar bulundu. Mikrosızıntı klinik açıdan değerlendirildiğinde ise; 3 ara-yüzey arasında bariz farklılıkların olduğu tespit edildi.

Özet (Çeviri)

Comparison of 3 different implant-abutment junction types on bacterial microleakage and flora. Department of prosthodontics doctorate programme.Thesis of doctorate. ANKARA 2011The aim of this clinical prospective study was compare the bacterial microleakage between implant and abutment interfaces of 3 different implant-abutment junction systems.Ten implants with a paralel internal hexagon junction type (MIS), 10 implants with a 11-degree tapered internal trilob junction type (Megagen), and 10 implants with a 1.5 degree locking taper junction type (Bicon) were placed into edentulous alveolar bones of 30 patients. Bacterial samples were obtained from the internal holes of the implants before and after functional loading. Additional bacterial samples were obtained from the sulcus of the gingiva adjacent to the implant as control. All samples were subjected to DNA extraction procedure, bacterial DNAs were obtained and amplified by PCR (polymerase chain reaction). Bacterial identification was performed with the Micro-IDent ® kit.The result of the study, statistically significant differences were found between 3 different implant-abutment junction types. Locking taper junction type was more resistent to microleakage than the internal hexagonal junction type and internal trilob junction type.

Benzer Tezler

  1. Bazı esterlerin kinetik incelenmesi ve termodinamik parametrelerin belirlenmesi

    Kinetic study and detesmination of thermodnamic parameters of some esters

    İBRAHİM TAŞ

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    Uludağ Üniversitesi

    Kimya Ana Bilim Dalı

    Yükleniyor...

  2. İzmir'de bazı yolların kapatılarak yaya bölgeleri oluşturma da kent peyzajını geliştirme açısından yeniden planlanması üzerinde araştırmalar

    Başlık çevirisi yok

    BAHAR TÜRKYILMAZ

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    Ege Üniversitesi

    Şehir ve Bölge Planlama Ana Bilim Dalı

    Yükleniyor...

  3. Testosteron dihidrotestosteron ve östrojenin benign prostat hiperplazisindeki etyolojik rolleri

    The roles of testosterone, dihydrotestosterone and estradiole on the etiology of benign prostatic hyperplasia

    HALUK TOKUÇOĞLU

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1986

    Gazi Üniversitesi

    Üroloji Ana Bilim Dalı

    Yükleniyor...

  4. Süt formüllerinin tüketim uygulamaları ve süt formüllerinin C vitamini içeriği ile pH değerleri

    Başlık çevirisi yok

    GÖNÜL VAROL

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    İstanbul Üniversitesi

    Çocuk Gelişimi Ana Bilim Dalı

    Yükleniyor...