Geri Dön

BI-RADS kategori 3 olarak tanımlanan lezyonların uzun dönem takipte negatif ön görü değerinin belirlenmesi ve hastaya ait karakteristik özelliklerin BI-RADS kategori 3 değerlendirmesindeki olası etkilerinin araştırılması

The negative predictive value of BI-RADS category 3 assesment after a long term follow-up and the possible effects of patient related factors on BI-RADS category 3 assessment

  1. Tez No: 331542
  2. Yazar: HİLAL ALTAŞ AYDIN
  3. Danışmanlar: PROF. DR. M. ERKİN ARIBAL
  4. Tez Türü: Tıpta Uzmanlık
  5. Konular: Radyoloji ve Nükleer Tıp, Radiology and Nuclear Medicine
  6. Anahtar Kelimeler: Mamografi, Meme neoplazmları, Neoplazm evreleri, Neoplazmlar, Retrospektif çalışmalar, Teşhis, Teşhis-ayırıcı, Mammography, Breast neoplasms, Neoplasm staging, Neoplasms, Retrospective studies, Diagnosis, Diagnosis-differential
  7. Yıl: 2013
  8. Dil: Türkçe
  9. Üniversite: Marmara Üniversitesi
  10. Enstitü: Tıp Fakültesi
  11. Ana Bilim Dalı: Radyoloji Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

BI-RADS kategori 3 yüksek olasılıkla benin olarak kabul edilen lezyonları tanımlamaktadır. Bu çalışma; BI-RADS kategori 3 değerlendirmesinin kliniğimizde ne sıklıkla kullanıldığı, ne kadar süre takip edildiği, bu süre sonunda değerlendirmenin negatif öngörü değeri ve literatüre uygunluğunu araştıran klinik performans değerlendirmesidir. Ayrıca çalışmada hastaya veya radyoloğa ait faktörlerin BI-RADS kategori 3 değerlendirmesindeki olası etkileri belirlenmeye çalışılmıştır. Eylül 1997? Nisan 2010 tarihleri arasında, kliniğimize tarama mamografisi yaptırmak üzere başvurmuş olan, 9602 olgunun mamografi takip formları retrospektif olarak değerlendirildi. BI-RADS kategori 3 olarak değerlendirilmiş ve kısa aralıklı takibe çağrılmış olan 881 olgunun mamografi takip formları incelenerek çalışmaya dahil edildi. Patoloji sonuçları altın standart olarak kabul edilerek, radyoloğun 6. ay, 12. ay ve en son kontrolde belirlemiş olduğu BI-RADS kategori değerlendirmesinin negatif ön görü değerleri hesaplandı. Olguların takip protokolüne uyumu değerlendirildi.Hastaya ait risk faktörlerine ve radyoloğun deneyim süresine göre BI-RADS kategori 3 olguların dağılımı incelendi.Taranan 9602 olgu içerisinde BI-RADS kategori 3 olarak değerlendirilen olgu sayısı 881 (%9,2) idi. İki yüz yetmişbeş (%31) olgununhiçbir kontrole gelmediği saptandı. BI-RADS kategori 3 olarak tanımlanan ve en az bir kere kontrole gelmiş olan 606 (%69) olgunun mamografi ile ortalama takip süresi 36,9 ay idi. Biyopsi yapılan 23 olgunun (%3,8) 5?inde(% 0,8) malinite saptandı. Altıncı ay kontrolünde negatif öngörü değeri %90,9, on ikinci ay kontrolünde negatif öngörü değeri %87,5 ve en son kontrolde negatif öngörü değeri %100 olarak hesaplandı. Olguların 6. ay kontrolüne %50 oranında, 12. ay kontrolüne %30 oranında, on ikinci ay sonrası herhangi bir kontrole %48 oranında uyum sağladığı saptandı.Sonuç olarak; kliniğimizde tarama mamografisi sonrası BI-RADS kategori 3 değerlendirmesi % 9,2 oranında kullanılmış olup literatür bilgisine uygundur. BI-RADS kategori 3 olarak değerlendirilen olgular arasında % 0,8 oranında malinite saptanmış olup bu kategoriye atfedilen malinite risk aralığıiii(<%2) içerisindedir. Olguların kısa aralıklarla takip protokolüne uyumuoldukça düşük ve düzensizdir. Bu nedenle klinisyen ve hasta, takip protokolünün kritik önemi ile ilgili olarak açık ve net bir şekilde bilgilendirilmelidir. BI-RADS raporlama ve veri sisteminin, özellikle de BIRADS kategori 3 ? kısa aralıklı takip protokolünün Türk toplumunda kullanımı ile ilgili sunulmuş veriler oldukça sınırlıdır. Bu çalışmada BI-RADS kategori 3 değerlendirmesi ? kısa aralıklı takip protokolünün, tarama mamografisi sonrası Türk toplumunda doğru şekilde uygulanabilir bir değerlendirme kategorisi olduğu gösterilmiştir

Özet (Çeviri)

BI-RADS category 3 defines lesions with a high probability of benignity. This is a performance study of our clinic, evaluating the frequency of BI-RADS category 3 utilization, the length of follow-up periods, the negative predictive value of such a designation in the light of the final outcome and concordance with the current literature. The possible effects of patient and radiologist related factors on BI-RADS category 3 assessment are also studied.Screening mammography records of 9602 patients, between September 1997 and April 2010, were evaluated retrospectively. 881 patient assessed as BI-RADS category 3 and called back for short interval follow-up protocol, were included in the study. Negative predictive values for 6th, 12th and final controls were calculated according to radiologist prediction, accepting the pathology results as gold standard. The compliance of patients to follow-up protocol was also evaluated. The distribution of BI-RADS category 3 lesions according to patient related breast cancer risk factors and radiologists experience was studied.881 out of 9602 cases was defined as BI-RADS category 3 (9.2%). Two hundred and seventy five cases were lost to follow-up. Mean follow-up period of 606 patients (69%) with BI-RADS category 3 assesment who had applied for control at least once was 36.9 months. Biopsy results in 5 out of 23 patients were malignant. Negative predictive values for 6th, 12th and final controls were 90.9%, 87.5% and 100%, respectively. Patient compliance for 6th, 12th and any control beyond 12th month was 50%, 30% and 48%, respectively.BI-RADS category 3 designation was utilized in 9.2% cases of screening mammography in our clinic, which is in accordance with the literature. Among such cases cancer detection rate was 0.8% which is also within the attributed risk intervals (<2%). Patients? compliance with short interval follow-up protocol was quite low and irregular. For this reason, the referring clinician and the patient must be precisely informed about the critical importance of the follow-up protocol. The utility of BI-RADS, especially category 3 and short interval follow-up protocol, is not well established for vTurkish population. This study confirms the applicability of BI-RADS category 3 and short interval follow-up protocol, after screening mammography for the Turkish population.

Benzer Tezler

  1. Ovulasyon indüksiyonu tedavisinde folliküler gelişimin ultrasonografik takibi

    Başlık çevirisi yok

    MERİH BAYRAM

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1987

    Kadın Hastalıkları ve DoğumGazi Üniversitesi

    Kadın Hastalıkları ve Doğum Ana Bilim Dalı

    DOÇ. DR. MÜLAZIM YILDIRIM

  2. Süt formüllerinin tüketim uygulamaları ve süt formüllerinin C vitamini içeriği ile pH değerleri

    Başlık çevirisi yok

    GÖNÜL VAROL

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    Besin Hijyeni ve Teknolojisiİstanbul Üniversitesi

    Çocuk Gelişimi Ana Bilim Dalı

    DOÇ. DR. TÜRKAN KUTLUAY

  3. Gelişim nörolojisi polikliniğine başvuran nöral tüp defektli olgularda prospektif bir inceleme

    Başlık çevirisi yok

    İLKBAHAR EMİNE GÜLTEKİN

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    Çocuk Sağlığı ve Hastalıklarıİstanbul Üniversitesi

    Aile Sağlığı Ana Bilim Dalı

    DOÇ. DR. SELÇUK APAK

  4. Dokuma kumaşlarda örgü tipinin ham kumaşın boyutları ve geometrik özellikleri üzerindeki etkilerinin araştırılması

    Başlık çevirisi yok

    EMEL ÖNDER

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    Tekstil ve Tekstil MühendisliğiEge Üniversitesi

    Tekstil Mühendisliği Ana Bilim Dalı

    DOÇ. DR. GÜNGÖR BAŞER

  5. Değişik derim zamanı ve önsoğutmanın Bursa siyahı incir çeşidinin meyve kalitesi ve pazarlama süresi üzerine etkileri

    Effects of haruest time and precooling on fruit quality and shelf-life of the fig variety“Bursa siyahı”

    FÜSUN GÜRSEL ÇELİKEL

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    Gıda MühendisliğiEge Üniversitesi

    Bahçe Bitkileri Ana Bilim Dalı