Geri Dön

Solid-state kardiyak gama kamera ile pet/bt'de miyokardiyal perfüzyon görüntülemedeki hareket artefaktlarının karşılaştırılması: Fantom çalışması

The comparison of movements artifacts in myocardial perfusion scanning in solid-state cardiac gamma camera and pet/ct: Phantom study

  1. Tez No: 334329
  2. Yazar: SEMRA DÖNMEZ
  3. Danışmanlar: YRD. DOÇ. ARİF KÜRŞAD AYAN
  4. Tez Türü: Yüksek Lisans
  5. Konular: Fizik ve Fizik Mühendisliği, Physics and Physics Engineering
  6. Anahtar Kelimeler: Miyokard, Perfüzyon-bölgesel, Pozitron emisyon tomografi, Radyonüklid görüntüleme, Anthropomorphic Phantom, Myocardial Perfusion Scintigraphy, PET/BT, Solid State Gama Kamera, SPECT, Myocardium, Perfusion-regional, Positron-emission tomography, Radionuclide imaging
  7. Yıl: 2013
  8. Dil: Türkçe
  9. Üniversite: Atatürk Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Nükleer Tıp Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Solid-State Kardiyak Gama Kamera Gle Pet/Bt?de Miyokardiyal Perfüzyon Görüntülemedeki Hareket Artefaktlarının KarGılaGtırılması:Fantom ÇalıGması Amaç. Bu çalışmanın amacı, kardiyak gama kamera ile PET/BT.de miyokardiyal perfüzyon görüntülemedeki aksiyel yöndeki hasta hareketlerinden kaynaklanan artefaktların karşılaştırılması, olası hasta hareketlerinin hangi boyutta defekt oluşturabileceğinin bulunması, bu defektlerin toplam çekim süresinin hangi safhasında meydana gelebileceğini ve hangi sistemde yapılan kalp çalışmalarının daha güvenilir olduğunu araştırmaktır. Materyal ve Metot.Çalışmada Anthropomorphic SPECT kalp fantomu iki ayrı kamera sisteminde hasta hareketini simüle etmek için kullanılmıştır. Kalp fantomu her iki sistemde de tek gün protokolünde rest çalışması başladıktan sonra sırasıyla; çekim süresinin başında, ortasında ve sonunda hareketsiz, 4 mm, 12 mm ve 20 mm.lik hareket oluşturularak 10 kez tekrar edildi. Daha sonra her görüntü tek tek analiz edildikten sonra polar harita sonuçları üzerinden istatistiksel analiz yapıldı. Bulgular.Kardiyak gama kamera sonuçlarında çekim süresinin başında ve sonunda oluşturulan 4 mm, 12 mm ve 20 mm.lik hareketler ile hareketsiz çalışmalar arasında anlamlı fark bulunmadı. Çekim süresinin ortasında oluşturulan hareketler arasında istatistiksel olarak anlamlı bir fark bulundu (p<0.05). Post hoc analizlerde bu farkın 20 mm hareket oluşturulan grup ile hareketsiz ve 4 mm hareket oluşturulan gruptan kaynaklandığı anlaşılmıştır. PET/BT sisteminde ise çekim süresinin başında ve ortasında oluşturulan, 4 mm, 12 mm ve 20 mm.lik hareketler ile hareketsiz çalışmalar arasında istatistiksel fark bulunmadı. Çekim süresinin sonunda oluşturulan hareketler arasında ise istatistiksel olarak anlamlı bir fark bulundu. Post hoc analizlerde bu farkın

Özet (Çeviri)

The Comparison of Movements Artifacts in Myocardial Perfusion Scanning In Solid-State Cardiac Gamma Camera and PET/CT:Phantom Study Aim.The aim of this article is to compare the artifacts based on the patient movement while myocardial perfusion scanning with cardiac gamma camera and PET/CT, to determine the size of the defects which patient movement causes, to research at which shooting time phase these defects would occur and in which system the studies are more reliable. Material and Method.Anthropomorphic SPECT cardiac phantom is used to simulate the movement of the patient in two separate camera systems in this study. As soon as one day protocol rest study was started, cardiac phantom was repeated 10 times in both systems respectively; at the beginning, mid and end of shooting time without motion and 4mm, 12mm and 20mm with motion creating. After analyzing each image one by one, polar map was based on the results of statistical analysis. Results.According to cardiac gamma camera results; there was no statistical significant difference between 4mm, 12mm and 20mm of movements generated at the beginning and end of study. A statistically significant difference was found between the movements created in the mid of shooting time (p<0.05). It was understood in post hoc analysis that; this difference was derived from 20mm group without motion and 4mmgroup with motion. In PET/CT study; there was no statistically significant difference between 4mm, 12mm and 20mm of movements generated at the beginning and mid of study. A statistically significant difference was found between the movements created in the end of shooting time (p<0.05). It was understood in post hoc analysis that; this difference was derived from 20 mm group generated motion and 12mm group with motion. Conclusion.When the artifacts based on axial patient movement in MPS studies in cardiac gamma camera and PET/CT was compared, it was understood that cardiac gamma camera was more sensitive and reliable than PET/BT.

Benzer Tezler

  1. Kobalt seçici sensörün akış enjeksiyon analiz sistemlerinde kullanımının araştırılması ve iskemi modifiye albümin (ima) tayini için uygulanması

    Investigation of cobalt selective sensor on usage of fia system and applied for assingment of ischemia modified albumin (ima)

    HAKAN TURMUŞ

    Yüksek Lisans

    Türkçe

    Türkçe

    2015

    BiyomühendislikYıldız Teknik Üniversitesi

    Biyomühendislik Ana Bilim Dalı

    PROF. DR. İBRAHİM IŞILDAK

  2. Cıva(II) iyonuna karşı seçici ve hassas kromenilyum-siyanin tabanlı yeni bir kemodozimetrenin geliştirilmesi

    Development of a new chromenylium-cyanine based chemodosimeter selective and sensitive for mercury(II) ion

    MUHAMMED İKBAL GÜNDÜZ

    Yüksek Lisans

    Türkçe

    Türkçe

    2024

    Kimyaİstanbul Teknik Üniversitesi

    Kimya Ana Bilim Dalı

    PROF. DR. İSMAİL YILMAZ

  3. Lenfoma ve solid tümör tanılı pediatrik onkoloji hastalarında antrasikline bağlı akut ve kronik kardiyotoksisitenin retrospektif değerlendirilmesi

    Retrospective evaluation of anthracycline-induced acute and chronic cardiotoxicity in pediatric oncology patients with lymphoma and solitary tumors

    ESRA KARATAŞ

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2025

    Çocuk Sağlığı ve HastalıklarıDokuz Eylül Üniversitesi

    Çocuk Sağlığı ve Hastalıkları Ana Bilim Dalı

    DOÇ. DR. DENİZ KIZMAZOĞLU

  4. Eras çağında torakoskopik lobektomi uygulanan hastalarda intraoperatif hedefe yönelik sıvı tedavisinin hasta sonuçlarına etkisi

    Impact of intraoperative goal-directed fluid therapy on patient outcomes in patients undergoing thoracoscopic lobectomy in the eras era

    MERTCAN ÇETECİ

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2024

    Anestezi ve ReanimasyonÇukurova Üniversitesi

    Anesteziyoloji ve Reanimasyon Ana Bilim Dalı

    DOÇ. DR. DEMET LAFLI TUNAY

  5. Diffüz İdiyopatik İskelet Hiperosteozu(DİSH) sıklığı ve özellikleri

    Prevalence and characteristics of Diffuse Idiopathic Skeletal Hyperostosis (DISH)

    BERNA BULUT ATAYETER

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2026

    İç HastalıklarıSüleyman Demirel Üniversitesi

    İç Hastalıkları Ana Bilim Dalı

    PROF. DR. ATALAY DOĞRU