Geri Dön

Bakır tayininde atom tuzaklı atomik absorpsiyon spektrometresi metodunun kullanılması ve yöntemin interfer çalışmaları

Determinaton of copper with interference studies by atom trapping-atomic absorption spectrometry method

  1. Tez No: 335500
  2. Yazar: AYŞE GÜNERİ
  3. Danışmanlar: DOÇ. DR. IŞIL AYDIN
  4. Tez Türü: Yüksek Lisans
  5. Konular: Kimya, Chemistry
  6. Anahtar Kelimeler: Bakır, çme Suyu, FAAS, Yarıklı Kuvars Tüp (SQT), Copper, Drinking Water, FAAS, Slotted Quartz Tube (SQT)
  7. Yıl: 2012
  8. Dil: Türkçe
  9. Üniversite: Dicle Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Kimya Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Metal tayininde alevli atomik absorpsiyon spektrofotometresi (FAAS) oldukça sık kullanılan bir yöntemdir. Atom tuzakları geli tirilerek FAAS tekni inin duyarlılı ı son yıllarda giderek arttırılmaktadır. Atom tuzakları kullanımı ile FAAS tekni inin gözlenebilme sınırı mg/L seviyesinden ng/mL düzeyine indirilmi tir. Yarıklı kuvars tüp (SQT), bu atom tuzaklarından biridir. Bakırın FAAS ile tayininde yarıklı kuvars tüp (SQT) kullanarak duyarlı bir metot geli tirmeyi amaçlayan bu çalı ma 5 adımdan olu maktadır. Birinci adımda FAAS ile direk analizler gerçekle tirilmi tir. kinci adımda SQT, FAAS?ye bir aparat olarak monte edilerek analizler yapılmı tır. SQT kullanmanın amacı, analit atomlarını SQT yüzeyinde tutarak ölçüm bölgesinde kalma sürelerini artırmak ve böylece duyarlılık artı ı elde etmektir. Bu adımda birinci adıma göre yakla ık 2.21 kat duyarlılık artı ı elde edilmi tir. Üçüncü adımda SQT-ATFAAS ortamında analizler gerçekle tirilmi tir. Bu adımda, aleve gönderilen analit SQT yüzeyinde belirli bir süre toplanır. Daha sonra aleve dü ük hacimde metil izobütilketon (MIBK) gönderilerek analit atomlarının hızla SQT yüzeyinden uzakla tırılmaları sa lanır. Dördüncü adımda ise SQT?nin yüzeyi bazı metaller ile kaplanmı tır. En yüksek absorbans de eri tungsten kaplı SQT ile elde edilmi tir. W kaplı SQT-AT-FAAS de duyarlılık artı ının daha fazla oldu u gözlenmi tir. Ayrıca her bir adımda asetilen akı hızı, örnek akı hızı, asit konsantrasyonu gibi parametreler optimize edilmi tir. Be inci adımda da interfer çalı maları yapılmı tır. Metodun analitiksel do rulu u 1643e National?Institute of Standard & Technolgy SRM ile kontrol edildi. Uygulama olarak çe itli bölgelerden çıkarılan ve ticari amaçlı satılan içme sularının analizleri yapıldı. Analiz sonuçları Dünya Sa lık Örgütü (WHO) 1999 Avrupa Birli i (EC) 1998 ve Türk Standartları Enstitüsü (TSE) 266/2005 yönetmenliklerinde izin verilen konsantrasyon de erleri ile kıyaslandı. Analizi yapılan sulardaki bakır konsantrasyonun uygun oldu u görüldü.

Özet (Çeviri)

Flame Atomic Absortion Spectrometry (FAAS) is a constantly used method for detection of metals. In the recent years atom trapping have been improved to increase sensitive of tecnique. The detection limit of FAAS technique was reduced to ng/mL level through the agency of atom trapping while it was mg/mL. Slotted of Quartz Tube (SQT) is one of these atom trappings. In this study, a sensitive method was developed by using SQT for determination of copper by FAAS method. SQT was used five different ways for this thesis. The first step of analysis was carried out directly by FAAS. Secondly, SQT as apparatus installed to the FAAS. It was aimed to increase stay time of copper atoms in the atomization region, it was observed about 2,21times increase in sensitivity. SQT-AT-FAAS analysis was carried out in the third step. In this step, analyte atoms are collected on the SQT surface in a certain time. Then the low volume of methyl isobutyl ketone (MIBK) sent to the analyte atoms in SQT surface are rapidly removed from of is provided. The optimum parameters were obtained. In the fourth step, some of the metals is covered with SQT surface. The highest absorbance value was obtained with coated tungsten. W coated SQT-AT-FAAS is higher sensitivity than the others. In addition, acetylene flow rate and sample flow rate at each step are optimized parameters such as acid concentration. Interfer studies were carried out in the fifth step. The accuracy of the system's 1643 National-Institute of Standard & Technolgy was checked with standard reference material. The commercial drinking waters are purchased from markets in Turkey and its were analyzed by these methods. The results of analysis compared with the World Health Organization (WHO), in 1999 the European Union (EC) 1998 and the Turkish Standards Institute (TSE) 266/2005. Analysis results of the copper values of the waters were found to be within the limit values.

Benzer Tezler

  1. Interference studies in atom trapping atomic absorption spectrometry

    Atom tuzaklı atomik absorpsiyon spektrometrisinde girişim çalışmaları

    RAFİK S. HELLES

    Yüksek Lisans

    İngilizce

    İngilizce

    1993

    KimyaOrta Doğu Teknik Üniversitesi

    Kimya Ana Bilim Dalı

    PROF. DR. YAVUZ ATAMAN

  2. Bakır, kurşun ve demir elementlerinin alevli atomik absorpsiyon spektrofotometre sisteminde düşük seviyelerde tayinlerine yönelik analitik stratejilerin geliştirilmesi

    The development of analytical strategies for the determinations of copper, lead and iron elements at trace levels by atomic absorption spectrophotometer

    BUSE TUĞBA ZAMAN

    Yüksek Lisans

    Türkçe

    Türkçe

    2018

    KimyaYıldız Teknik Üniversitesi

    Kimya Ana Bilim Dalı

    PROF. DR. SEZGİN BAKIRDERE

  3. Determination of cadmium using slotted quartz tube atom trap atomic absorption spectrometry and metal coatings

    Yarıklı kuvars tüp atom tuzağı ve metal kaplamalar kullanarak alevli atomik absorpsiyon spektrometri ile kadmiyum tayini

    G. PELİN ÖZCAN GURBETOĞLU

    Yüksek Lisans

    İngilizce

    İngilizce

    2010

    KimyaOrta Doğu Teknik Üniversitesi

    Kimya Bölümü

    PROF. DR. O. YAVUZ ATAMAN

  4. Oxidation state related evaluation of tellurium determination by flame AAS and use of slotted silica trap

    Alevli AAS ile tellür tayininde değerlikle ilgili değerlendirme ve yarıklı silika tuzağının kullanımı

    HÜSEYİN BEKİR YILDIZ

    Yüksek Lisans

    İngilizce

    İngilizce

    2002

    KimyaOrta Doğu Teknik Üniversitesi

    Kimya Ana Bilim Dalı

    PROF.DR. O. YAVUZ ATAMAN