Geri Dön

Farklı yoğunluktaki kemiklerde mini-implant ring aparatının minivida stabilitesi üzerine etkisi

Efficacy of mini implant ring apparatus on the stability of mini screws in different bone densities

  1. Tez No: 340705
  2. Yazar: ABİDDİN ACAR
  3. Danışmanlar: DOÇ. DR. DERYA ÇAKAN
  4. Tez Türü: Doktora
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Minivida, Mini implant ring (MİR) aparatı, kortikal kemik yoğunluğu, primer stabilite, Dental implantasyon, Dental implantlar, Kemik dansitesi, Kemik ve kemikler, Kemik vidaları, Protezler ve implantlar, Mini screws, Mini implant ring (MIR) apparatus, cortical bone density, primary stability, Dental implantation, Dental implants, Bone density, Bone and bones, Bone screws, Prostheses and implants
  7. Yıl: 2013
  8. Dil: Türkçe
  9. Üniversite: Yeditepe Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Ortodonti Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Bu çalışmanın amacı, kortikal kemik yoğunluğunun minivida stabilitesine olan etkisini değerlendirmek ve mini implant ring (MİR) aparatının farklı yoğunluktaki kemiklerde minivida stabilitesi üzerine olan etkinliğini incelemektir. Bu amaçla çalışmada, 108 adet 1,6 mm çapında, 8 mm uzunluğunda konik minivida, 54 adet MİR aparatı ve farklı kortikal kemik yoğunluğundaki yapay kemikler kullanılmıştır. Kontrol gruplarını 20, 30 ve 40 pcf kortikal kemik yoğunluğuna sahip yapay kemiklere uygulanmış minividalar, test gruplarını ise yine 20, 30 ve 40 pcf yoğunluğuna sahip yapay kemiklere MİR ile uygulanmış minividalar oluşturmaktadır. Grupların maksimum uygulama torkları (MUT), kuvvet dirençleri (KD) ve maksimum çıkarma torkları (MÇT) ölçülmüştür. Veriler istatistiksel olarak değerlendirilmiştir. Farklı kortikal kemik yoğunluklarında ölçülen MUT, KD ve MÇT değerleri arasında istatistiksel olarak anlamlı fark bulunmuştur (p<0,001). Tüm kortikal kemik yoğunluklarında MİR grubunun, MUT, KD ve MÇT değerleri, kontrol grubunun MUT, KD ve MÇT değerlerine göre istatistiksel olarak anlamlı derecede yüksek bulunmuştur (p<0,001). Sonuç olarak, yapay kortikal kemik yoğunluğunun artması minividaların stabilitesini arttırmaktadır. Benzer şekilde MİR?le beraber uygulanan minividaların başlangıç stabiliteleri kortikal kemik yoğunlukları arttıkça artmaktadır. MİR aparatı uygulaması ankraj değerlerini olumlu yönde değiştirmektedir.

Özet (Çeviri)

The aim of this study is to evaluate the influence of cortical bone density on mini screw stability and to investigate the efficacy of mini implant ring apparatus (MIR) on the stability of mini screws in different bone densities. For this purpose, 108 conical mini screws (1.6 mm diameter, 8 mm length), 54 MIR apparatus and artifical bone samples with different cortical densities were used in this study. Control groups consisted of mini screws applied to artificial bone samples with densities of 20, 30 and 40 pcf whereas experiment group included MIR supplemented mini screws mounted to artificial bone samples with the same densities as the former group. Maximum insertion torque (MIT), force resistance (FR) and maximum removal torque values (MRT) were measured for each group. The findings were evaluated statistically. Statistically significant differences were found among MIT, FR and MRT values measured in different cortical bone densities (p<0.001). MIT, FR and MRT values for MIR group were found to be statistically significantly higher than those for control group in all cortical bone densities (p<0.001). To conclude, increase in cortical bone density also enhances the primary stability of mini screws. Likewise, stability of MIR supplemented mini screws increased accordingly with the bone densities. Application of MIR apparatus influences anchorage values in a positive manner

Benzer Tezler

  1. Bazı esterlerin kinetik incelenmesi ve termodinamik parametrelerin belirlenmesi

    Kinetic study and detesmination of thermodnamic parameters of some esters

    İBRAHİM TAŞ

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    Uludağ Üniversitesi

    Kimya Ana Bilim Dalı

    Yükleniyor...

  2. İzmir'de bazı yolların kapatılarak yaya bölgeleri oluşturma da kent peyzajını geliştirme açısından yeniden planlanması üzerinde araştırmalar

    Başlık çevirisi yok

    BAHAR TÜRKYILMAZ

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    Ege Üniversitesi

    Şehir ve Bölge Planlama Ana Bilim Dalı

    Yükleniyor...

  3. Testosteron dihidrotestosteron ve östrojenin benign prostat hiperplazisindeki etyolojik rolleri

    The roles of testosterone, dihydrotestosterone and estradiole on the etiology of benign prostatic hyperplasia

    HALUK TOKUÇOĞLU

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1986

    Gazi Üniversitesi

    Üroloji Ana Bilim Dalı

    Yükleniyor...

  4. Süt formüllerinin tüketim uygulamaları ve süt formüllerinin C vitamini içeriği ile pH değerleri

    Başlık çevirisi yok

    GÖNÜL VAROL

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    İstanbul Üniversitesi

    Çocuk Gelişimi Ana Bilim Dalı

    Yükleniyor...