Yeni geliştirilen mini implant ring aparatının farklı yönlerdeki kuvvetler karşısında minivida stabilitesi ve kuvvet direncine olan etkisi

Effects of newly designed mini implant ring apparatus on miniscrew stability and force resistance against forces in different directions

  1. Tez No: 340709
  2. Yazar: VOLKAN OSMAN UYAR
  3. Danışmanlar: DOÇ. DR. FULYA ÖZDEMİR
  4. Tez Türü: Doktora
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2012
  8. Dil: Türkçe
  9. Üniversite: Yeditepe Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Ortodonti Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 156

Özet

Bu çalışmanın amacı, in-vitro ortamda farklı iki açıda yerleştirilen normal minividalar ile boyun kısmına mini implant ring (MİR) aparatı uygulanmış olan minividaların, farklıyönlerdeki kuvvetler karşısında başlangıç stabilitelerini analiz etmek ve karşılaştırmaktır.Bu amaçla çalışmada, 80 adet 1,6 mm çapında 8 mm uzunluğundakonik TM (Trimed, Ankara, Türkiye) minivida ve 40 adet MİR aparatı kullanılmıştır. Çalışmadaki bütün minividalar ve MİR aparatları laboratuvar ortamında sığır kalça kemiğinden elde edilen örneklere uygulanmıştır. Uygulama öncesi sığır kalça kemiği örneklerinin kortikal kemik kalınlıklarının (KKK) belirlenmesi amacıyla bilgisayarlı tomografi (BT) görüntüleri elde edilmiştir. Elde edilen KKK verileri doğrultusunda, 1 mm ile 1,5 mm arasında değişen değerlerde kortikal kemik kalınlığı olan kemik örnekleri, minividaların örneklere homojen dağılımı gerçekleşecek şekilde istatistiksel olarak gruplandırılmıştır.Çalışmada minividalar dört ayrı grup halinde kliniğimizde geliştirdiğimiz açılı minivida yerleştirme aparatı ile kemik yüzeylerine yerleştirilmiştir. Minividalar iki farklı yerleştirme açısında (70° ve 90°) kemik yüzeylerineuygulanmış, iki grupta bulunan minividalara MİR aparatı uygulanmıştır. Çalışmadaki birinci grup 30 adet 70°'lik açı ile yerleştirilmiş normal minividalar, ikinci grup 30 adet 70°'lik açı ile yerleştirilmiş MİR'li minividalar, üçüncü grup 10 adet 90°'lik açı ile yerleştirilmiş normal minividalar ve dördüncü grup ise 10 adet 90°'lik açı ile yerleştirilmiş MİR'li minividalardan oluşmaktadır.Çalışmadaki bütün minividaların, yerleştirme sırasında tork ölçer tornavida (Checkline TSD 50, USA) ile maksimum yerleştirme torku (MYT) değerleri ölçülmüştür. Daha sonra Instron test cihazı ile 70°'lik açı ile yerleştirilmiş olan minividalara 3 farklı yönde, 90°'lik açı ile yerleştirilmiş olanminividalara tek yönde minivida başı 0,6 mm yer değiştirene kadar kuvvet uygulanmış, minividaların gösterdikleri kuvvet direnç değerleri ölçülmüş ve kaydedilmiştir. Kuvvet direnci (KD) testi gerçekleştirilen minividalar, tork ölçer tornavida ile maksimum çıkarma torku (MÇT) değerleri ölçülerek kemikten çıkarılmıştır.Bulgular istatistiksel olarak değerlendirildiğinde, 70°'lik yerleştirme açısı ile yerleştirilen minividaların MYT, KD ve MÇT değerleri 90°'lik yerleştirme açısı ile yerleştirilen minividaların MYT, KD ve MÇT değerlerine göre istatistiksel olarak anlamlı derecede yüksek bulunmuştur (p

Özet (Çeviri)

The aim of this in-vitro study was to compare primary stability of normal miniscrews with primary stability of miniscrews supplemented by mini implant ring apparatus (MIR) in two different insertion angles against forces in differentdirections.For this purpose, a total of 80 conical TM (Trimed, Ankara Turkey) miniscrews (1,6 mm diameter and 8 mm length) and 40 MIR apparatus were used in our study. All of the miniscrews and MIR apparatus were applied to the specimens prepared from the ilium bone of bovine. Before application, in order to quantify the cortical bone thickness of the bone specimens, computed tomography (CT) images of bone specimens were obtained. In accordance with the cortical bone thickness values, bone specimens which contain cortical bone thickness ranging from 1 mm to 1.5 mm, were statistically so grouped that homogeneous distribution of miniscrews to bone specimens occurred.In the study miniscrews were divided into four groups and applied into bone specimens with the use of an angled miniscrew placement apparatus which was developed in our clinic. Miniscrews were placed into bone specimens at two different angles (70° and 90°) and MIR apparatus were applied to miniscrews in two groups. In the study first group consisted of 30 normal miniscrews placed at an angle of 70°, second group consisted of 30 miniscrews supplemented by MİR apparatus and were placed at an angle of 70°, third group consisted of 10 normal miniscrews placed at an angle of 90° and fourth group consisted of 10 miniscrews supplemented by MİR apparatus and placed at an angle of 90°.During placements, maximum insertion torque (MIT) values of all miniscrews were measured with the use of a torque screw driver (Checkline TSD 50, USA). After that, miniscrews placed at an angle of 70° were subjected to force applications in three different directions, miniscrews placed at an angle of 90° were subjected to force applications in one direction through a lateral displacement of 0.6 mm of the miniscrew with the use of the Instron test machine and force resistance (FR) values were measured and recorded. Maximum removal torque (MRT) values of tested miniscrews were measured with the use of the torque screw driver while removal from the bone.When the results were statistically evaluated, it was seen that MIT, FR and MRT values of miniscrews placed at an angle of 70° were significantly higher than MIT, FR and MRT values of miniscrews placed at an angle of 90° (p

Benzer Tezler

  1. Yeni geliştirilen mini implant ring aparatının minivida stabilitesi ve kuvvet direncine olan etkisi

    Effects of newly designed mini implant ring apparatus on miniscrew stability and force resistance

    MURAT TOZLU

    Doktora

    Türkçe

    Türkçe

    2010

    Diş HekimliğiYeditepe Üniversitesi

    Ortodonti Ana Bilim Dalı

    DOÇ. DR. FULYA ÖZDEMİR

  2. Miniplakların ağız içine cerrahi yönteme başvurulmadan yerleştirilmesi için geliştirilen yeni bir uygulama: 3-boyutlu sonlu elemanlar stres analizi ile uygulamanın etkinliğinin değerlendirilmesi

    New method for the placement of miniplates in mouth without surgical applications: Evaluation of the application with 3-dimensional finite element stress analysis

    VOLKAN AYKAÇ

    Doktora

    Türkçe

    Türkçe

    2013

    Diş HekimliğiGazi Üniversitesi

    Ortodonti Ana Bilim Dalı

    DOÇ. DR. MEHMET ÇAĞRI ULUSOY

  3. Mini ve nano robot motorlarının geliştirilmesi ve ortopedik cerrahide uygulanması

    Development of mini and nano robot motors and implementation in orthopedic surgery

    FATİH ERTEM

    Doktora

    Türkçe

    Türkçe

    2018

    Ortopedi ve TravmatolojiDokuz Eylül Üniversitesi

    Biyomekanik Ana Bilim Dalı

    PROF. DR. HASAN HAVITÇIOĞLU

  4. Tek taraflı molar distalizasyonu için geliştirilen mini-vida destekli yeni bir yöntemin dişsel ve iskeletsel etkilerinin incelenmesi

    Evaluation of the dental and skeletal effects of a new designed mini-screw supported unilateral molar distalization system

    ABDULKERİM BUĞRA

    Doktora

    Türkçe

    Türkçe

    2013

    Diş HekimliğiGazi Üniversitesi

    Ortodonti Ana Bilim Dalı

    PROF. DR. SEVİL AKKAYA

  5. Pd(II)'nin triazol kompleksi halinde amberlit XAD?2010 reçinesi üzerinde seçimli zenginleştirilmesi ve çevresel örneklerde tayini

    Selective preconcentration and determination of Pd(II) in environmental samples by formation a triazol complex on amberlite XAD-2010 resin

    HÜSEYİN SERENCAM

    Doktora

    Türkçe

    Türkçe

    2010

    KimyaKaradeniz Teknik Üniversitesi

    Kimya Ana Bilim Dalı

    PROF. DR. MEHMET TÜFEKÇİ