Vidasız morse taper ve vida bağlantılı dental implant sistemlerinde implant - abutment bağlantılarının mekanik dayanımının in vitro incelenmesi

Mechanical strength of dental implant systems with screwless morse taper and screw-retained implant - abutment connections: an in vitro study

  1. Tez No: 347590
  2. Yazar: CİHAN ŞADİ UĞUREL
  3. Danışmanlar: PROF. DR. GÜLBAHAR IŞIK ÖZKOL
  4. Tez Türü: Doktora
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2013
  8. Dil: Türkçe
  9. Üniversite: İstanbul Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 123

Özet

Vidasız morse taper implant - abutment bağlantısı geleneksel eksternal/internal vidalı bağlantıların alternatifi konumundadır. Bu in vitro çalışmanın amacı vidasız morse taper bağlantıya sahip bir implant sisteminin mekanik dayanımını değerlendirmek ve bu sistemi üç farklı internal vida bağlantılı implant sistemiyle karşılaştırmaktır. Bu çalışmada dört farklı implant sistemi karşılaştırılmıştır: Vidasız morse taper Tasarımmed Octo (İstanbul, Türkiye) ve internal vidalı sistemler; Straumann Bone Level (Basel, İsviçre), Biohorizons Internal (Birmingham, AL, ABD), Dentsply Friadent Xive (Mannheim, Almanya). Toplam 64 örnek özel kuronlarıyla birlikte hazırlanmıştır. Otuziki örnek dinamik, 32 örnek statik olarak yüklenmiştir. Dinamik yükleme çiğneme simülatörüyle 120 N, 1,75 Hz frekans ve 1,2 x 106 yükleme sayısı ile yapılmıştır. Statik yükleme üniversal test cihazı ile 30° eğimle 2 mm/dk hızla gerçekleştirilmiştir. Dinamik yüklemede başarısızlık görülen yükleme sayıları, statik yüklemede başarısızlık görülen kırılma/bükülme kuvvet değerleri kaydedilmiştir. İstatistiksel analizler Dunn'ın çoklu karşılaştırma yöntemiyle yapılmıştır. Dinamik yüklemede başarısızlık görülen medyan yükleme sayıları şu şekildedir: Octo 86.354 (24.810-153.875), Straumann 1.200.000 (1.156.618-1.200.000), Biohorizons 539.719 (437.224-858.732), Xive 139.411 (139.411-139.411). Statik yüklemede görülen medyan kırılma/bükülme kuvvet değerleri ise şu şekildedir: Octo 429,6 N (404,5-482,7), Straumann 574,6 N (544,6-629,9), Biohorizons 548,7 N (532,9-567,3), Xive 431,5 N (412,5-520,5). Her iki yükleme koşulunda da implant sistemleri arasında anlamlı farklılıklar bulunmuştur (p?0,05). Octo implant sisteminin vidasız morse taper bağlantısı, internal vida bağlantılı Straumann ve Biohorizons sistemlerinden istatistiksel olarak anlamlı düşük yükleme sayısı ve kırılma/bükülme kuvvet değeri göstermiş, ancak Xive implant sistemi ile arasında anlamlı farklılık gözlenmemiştir. Bu çalışma sonucunda vidasız morse taper bağlantının mekanik dayanımı internal vidalı bağlantılardan düşük bulunmuştur. İmplant - abutment bağlantısının mekanik dayanımı implant çapı ve abutment vidası sıkma torku arttıkça artmaktadır. Anti-rotasyonel komponent tasarımının da bağlantı dayanımına etkisi bulunmaktadır.

Özet (Çeviri)

The screwless morse taper (SMT) implant-abutment connection is an alternative to conventional external/internal screw-retained connections. The aim of this in vitro study was to evaluate the mechanical resistance of an implant system with SMT connection and to compare this system with three different internal screw-retained (ISR) implant systems. Four implant systems were tested in this study: SMT system; Tasarimmed Octo (Istanbul, Turkey), ISR systems; Straumann Bone Level (Basel, Switzerland), Biohorizons Internal (Birmingham, AL, USA) and Dentsply Friadent Xive (Mannheim, Germany). Overall, sixty-four specimens with stylized single crowns were prepared: 32 for dynamic loading (DL) and 32 for static loading (SL). DL was done using a chewing simulator with 120 N at 1.75 Hz for 1.2 x 106 cycles and SL was done with a universal testing machine at a crosshead speed of 2 mm/min with an angulation of 30°. Cycles until failure from DL and fracture/bending loads in SL were recorded. Statistical analyses were made with Dunn's Multiple Comparison. The results showed that, median cycles until failure at DL were: Octo 86,354 (24,810-153,875), Straumann 1,200,000 (1,156,618-1,200,000), Biohorizons 539,719 (437,224-858,732), Xive 139,411 (139,411-139,411) and median fracture/bending loads in Newton at SL were: Octo 429.6 (404.5-482.7), Straumann 574.6 (544.6-629.9), Biohorizons 548.7 (532.9-567.3), Xive 431.5 (412.5-520.5). There were significant differences between the implant systems under both loading conditions (p?0.05) revealing that the Octo implant system's SMT connection showed significantly lower cycles to failures and fracture/bending loads compared to the ISR connections of the Straumann and Biohorizons implant systems. However there was no significant difference compared to the Xive implant system. From this study it can be concluded that, the mechanical strength of the SMT connection is lower than that of the ISR connections. The resistance of the implant - abutment connection raises with increasing implant diameter and abutment screw tightening torque values. Type of the anti-rotational component has also an effect on the strength of the implant - abutment connection.

Benzer Tezler

  1. Farklı implant abutment bağlantı tiplerinin klinik performanslarının değerlendirilmesi

    Evaluation of clinical performance of different implant abutment connection TYPES

    ŞAZİYE ESRA GÖÇOĞLU

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2022

    Diş HekimliğiSüleyman Demirel Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. SERHAT SÜHA TÜRKASLAN

  2. Mandibular tam protezleri destekleyen iki farklı implantın çevresindeki marjinal kemik kaybının ve kemik içi stabilite değerlerinin incelenmesi

    Evaluation of the marginal bone loss and stability values of two different implants supporting mandibular complete dentures

    ESMA GEÇKİLİ

    Doktora

    Türkçe

    Türkçe

    2014

    Diş Hekimliğiİstanbul Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. TAYFUN BİLGİN

  3. Farklı implant-abutment bağlantı tipleri ile farklı materyallerden üretilen abutmentlerin doğal diş-implant destekli sabit protezlerde stres dağılımının sonlu elemanlar analiz yöntemi ile incelenmesi

    Investigation of stress distribution in natural tooth-implant supported fixed prostheses of abutments made of different materials with different implant-abutment connection types finite element analysis method

    BÜŞRA EKİN KESKİN

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2024

    Diş HekimliğiKaradeniz Teknik Üniversitesi

    Protetik Diş Tedavisi Ana Bilim Dalı

    PROF. DR. FATİH MEHMET KORKMAZ

  4. Sürtünme karıştırma kaynağı birleştirmelerinde farklı karıştırıcı uç formlarının birleştirme kalitesine etkilerinin incelenmesi

    Investigation of the effects on bonding quality for different type of mixer pin in friction stir welding

    KADİR KAPTAN

    Yüksek Lisans

    Türkçe

    Türkçe

    2008

    Teknik EğitimGazi Üniversitesi

    Makine Eğitimi Ana Bilim Dalı

    YRD. DOÇ. DR. HÜDAYİM BAŞAK

  5. Anterior omuz instabiliteli hastalarda uygulanan iliak kanat kemik blok transferinde tespit yöntemlerinin biyomekanik karşılaştırılması

    Biomechanic comparison of fixation methods in iliac crest bone block transfer applied to patients with anterior shoulder instability

    MUHAMMED FURKAN TOSUN

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2023

    Ortopedi ve TravmatolojiGazi Üniversitesi

    Ortopedi ve Travmatoloji Ana Bilim Dalı

    DOÇ. DR. TOLGA TOLUNAY