Geri Dön

The potential pesign and integration of Solimpek's PVT collector for Darent Valley Hospital

Başlık çevirisi mevcut değil.

  1. Tez No: 401844
  2. Yazar: RIZA BÜYÜKZEREN
  3. Danışmanlar: DR. ZAHIR DEHOUCHE
  4. Tez Türü: Yüksek Lisans
  5. Konular: Bilim ve Teknoloji, Enerji, Su Ürünleri, Science and Technology, Energy, Aquatic Products
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2014
  8. Dil: İngilizce
  9. Üniversite: Brunel Unıversıty London
  10. Enstitü: Yurtdışı Enstitü
  11. Ana Bilim Dalı: Yenilenebilir Enerji Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Özet yok.

Özet (Çeviri)

In accordance with the Renewable energy directive, the UK is currently working towards meeting its target of 15% energy consumption from renewable sources by 2020. Pursuant of this, there is increased pressure on technology development to improve the generation capacity of renewable energy power so that it becomes more and more reliable and effective. Solar power remains one of the best ways in which to generate energy in a sustainable way. This report investigates the technical, environmental and financial feasibility of the use of a Photovoltaic-Thermal (PV/T) collector plant at the NHS Darent Valley Hospital located in the South-east part of England, in Kent. An investigation of the PV/T technology was completed and the technology was tested under experimental test conditions. The solar irradiance and the temperature of the cells play the most essential role affecting the PV/T efficiency. The main role of the PV/T collector is removing heat from the cells using water which is heated with waste heat after PV cells module. Due to the fact that the water is heating and the solar cells are cooling, the total efficiency of the collector increases. The way in which the technology works can be observed using software at different levels observing such elements as the annual performance, monthly performance and daily performance. A complete analysis of the emission reduction, financial performance of the PV/T project of the hospital were carried out.The thesis will illustrate the way in which PV/T installation adds substantial benefits to the Darent Valley hospital given the potential of the reduction of Carbon emissions by around 12.7% and a payback period of 5.8 years.

Benzer Tezler

  1. Turkish mortgage market: An assessment of its potential and riskiness

    Türkiye ipotekli konut finansmanı piyasası: Potansiyele ve riskliliğe ilişkin bir değerlendirme

    MAHMUT KUTLUKAYA

    Doktora

    İngilizce

    İngilizce

    2015

    EkonomiOrta Doğu Teknik Üniversitesi

    İktisat Ana Bilim Dalı

    DOÇ. DR. EBRU VOYVODA

    DOÇ. DR. IŞIL EROL

  2. Ailelerin finansal risk yönetimine ilişkin tutum ve davranışlarının incelenmesi

    Examination of the attitudes and behaviours of families towards financial risk management

    ATEŞ BAYAZIT HAYTA

    Doktora

    Türkçe

    Türkçe

    2008

    Ev EkonomisiGazi Üniversitesi

    Ev Ekonomisi Bölümü

    PROF. DR. M.HAMİL NAZİK

  3. Bireysel kredi kullanımında hanehalkı davranışları ve sosyo-iktisadi etkileri

    Household behavior and socio-economic effects of using personal loan

    NESLİHAN KILINÇ

    Yüksek Lisans

    Türkçe

    Türkçe

    2012

    EkonomiGazi Üniversitesi

    İktisat Ana Bilim Dalı

    DOÇ. DR. FAHRİYE ÖZTÜRK

  4. Dış ticarette teslim ve ödeme şekilleri:Aksaray ili örneği

    Delivery and payment methods in foreign trade:Aksaray province example

    FATİH MUTLU

    Yüksek Lisans

    Türkçe

    Türkçe

    2024

    Uluslararası TicaretAksaray Üniversitesi

    İktisat Ana Bilim Dalı

    DOÇ. DR. VİLDAN GÜLPINAR DEMİRCİ

  5. Mal futuresları ve Türkiye`de uygulanabilirliği

    Commodity futures and applicability in Turkish agriculture industry

    PIRIL KOR

    Yüksek Lisans

    Türkçe

    Türkçe

    1998

    İşletmeAnkara Üniversitesi

    İşletme Ana Bilim Dalı

    PROF. DR. YÜKSEL KOÇ YALKIN