The potential pesign and integration of Solimpek's PVT collector for Darent Valley Hospital
Başlık çevirisi mevcut değil.
- Tez No: 401844
- Danışmanlar: DR. ZAHIR DEHOUCHE
- Tez Türü: Yüksek Lisans
- Konular: Bilim ve Teknoloji, Enerji, Su Ürünleri, Science and Technology, Energy, Aquatic Products
- Anahtar Kelimeler: Belirtilmemiş.
- Yıl: 2014
- Dil: İngilizce
- Üniversite: Brunel University London
- Enstitü: Yurtdışı Enstitü
- Ana Bilim Dalı: Yenilenebilir Enerji Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: 117
Özet
Özet yok.
Özet (Çeviri)
In accordance with the Renewable energy directive, the UK is currently working towards meeting its target of 15% energy consumption from renewable sources by 2020. Pursuant of this, there is increased pressure on technology development to improve the generation capacity of renewable energy power so that it becomes more and more reliable and effective. Solar power remains one of the best ways in which to generate energy in a sustainable way. This report investigates the technical, environmental and financial feasibility of the use of a Photovoltaic-Thermal (PV/T) collector plant at the NHS Darent Valley Hospital located in the South-east part of England, in Kent. An investigation of the PV/T technology was completed and the technology was tested under experimental test conditions. The solar irradiance and the temperature of the cells play the most essential role affecting the PV/T efficiency. The main role of the PV/T collector is removing heat from the cells using water which is heated with waste heat after PV cells module. Due to the fact that the water is heating and the solar cells are cooling, the total efficiency of the collector increases. The way in which the technology works can be observed using software at different levels observing such elements as the annual performance, monthly performance and daily performance. A complete analysis of the emission reduction, financial performance of the PV/T project of the hospital were carried out.The thesis will illustrate the way in which PV/T installation adds substantial benefits to the Darent Valley hospital given the potential of the reduction of Carbon emissions by around 12.7% and a payback period of 5.8 years.
Benzer Tezler
- Bireysel kredi kullanımında hanehalkı davranışları ve sosyo-iktisadi etkileri
Household behavior and socio-economic effects of using personal loan
NESLİHAN KILINÇ
- Bireysel kredi talebini etkileyen faktörler (Erzurum örneği)
Factors that affect consumer credit demand (Case of Erzurum)
ARİF ÇİLEK
- Kartlı aktif elektrik enerjisi sayaç sistemi
Başlık çevirisi yok
TURGAY ETÇİBAŞI
Yüksek Lisans
Türkçe
1995
Elektrik ve Elektronik Mühendisliğiİstanbul Teknik ÜniversitesiDOÇ.DR. MEHMET KORÜREK
- Uluslararası ticarette akreditifli ödemeler, bu ödeme yaklaşıma yönelik işletmelerin ihracat davranışı ve Konya'daki ihracatçılar üzerine bir araştırma
A research on letter of credit payments in international trade, export behavior of businesses towards this payment approach and exporters in Konya
NUR SELİN ATEŞ
Yüksek Lisans
Türkçe
2023
İşletmeKTO Karatay ÜniversitesiUluslararası Ticaret ve Lojistik Ana Bilim Dalı
PROF. DR. MURAT CANITEZ
- Van ili Bahçesaray ilçesi arıcılık işletmelerinin ekonomik analizi ve arı ürünlerinin pazarlanması
Economic analysis of beekeeping farms and marketing of bee products in Bahçesaray district of Van province
SİNAN AĞAR
Yüksek Lisans
Türkçe
2004
ZiraatYüzüncü Yıl ÜniversitesiTarım Ekonomisi Ana Bilim Dalı
DOÇ.DR. İBRAHİM YILDIRIM