Geri Dön

Demir bilya anot elektrotlar kullanarak elektrokoagülasyon prosesi ile içme sularından arsenik giderimi

Removal of arsenic from ground water using iron ball anodes by electrocoagulation process

  1. Tez No: 405392
  2. Yazar: EMRAH ŞIK
  3. Danışmanlar: PROF. DR. ERHAN DEMİRBAŞ, PROF. DR. MEHMET KOBYA
  4. Tez Türü: Doktora
  5. Konular: Kimya, Çevre Mühendisliği, Chemistry, Environmental Engineering
  6. Anahtar Kelimeler: Demir elektrot, Su arıtma, İçme suyu arıtma, Iron electrode, Water treatment, Drinking water treatment
  7. Yıl: 2015
  8. Dil: Türkçe
  9. Üniversite: Gebze Teknik Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Kimya Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Su kaynaklarındaki arsenik kirliliği, Türkiye'nin yansıra tüm dünyada karşılaşılan en önemli çevresel problemlerden biridir. Dünya Sağlık Örgütü (WHO, World Health Organisation) tarafından insan sağlığı üzerinde ki etkilerinden dolayı içme sulardaki maksimum arsenik konsantrasyonunu (MCL), 50 µg/L'den 10 µg/L'ye düşürmesi ile ülkemizde arsenik kirliliği sorunu daha da önemli bir hale gelmiştir. Bu yüzden sulardan daha etkili bir As giderim yönteminin gerekliliği ortaya çıkmıştır. Bu çalışmada Fe bilya anotların kullanıldığı hava takviyeli kesikli bir elektrokoagülasyon reaktörü ile içme sularından arsenik giderimi amaçlanmıştır. Deneysel tasarım optimizasyonu ile (Box-Behnken) sulardan As(III) ve As(V) giderim üzerine bağımsız değişken etkilerinin yansıra anyon ve katyonların As giderimi üzerine etkileri de incelenmiştir. Yanıtlar ile bağımsız değişkenler arasındaki ilişkinin kuatratik model eşitlikleri ile ifade edildiği ve ANOVA analizinde ise yüksek R2 (>0.85) and Adj-R2 (>0.80) değerleri bulunmuştur. Fe anotlar ile As(III) ve As(V) giderimi üzerine özellikle akım şiddeti (i), EC süresi (tEC), hava debisi (Qhava) ve reaktör anot yüksekliği (h)'nin etkisi olduğu görülmüştür. İstenen MCL'nin sağlanması bakımından değerlendirecek olursak; Fe anotlar ile As(V) gideriminin As(III)'den daha düşük tEC ve i değerlerin de sağlandığını göstermiştir. Ayrıca bu prosesin As(III) gideriminde de etkili olduğu saptanmıştır. Arsenik giderim verimi, zamana karşı CSiO3-Si ve CPO4-P anyonlarındaki konsantrasyon artışı ile azalırken diğer anyonlar önemli bir etki göstermemişlerdir. Diğer taraftan, zamana karşı CFe ve CCa katyonlarındaki artış arsenik giderim verimi üzerine önemli bir etki göstermişdir. Sonuç olarak bu çalışma sulardan As giderimi için alternatif bir proses olarak düşünülebilir.

Özet (Çeviri)

Arsenic contamination in the water sources is one of the most important environmental problems in the world including Turkey. The problem especially became more critical when World Health Organisation (WHO) decided to reduce the maximum level of arsenic concentration (MCL) in drinking water from 50 µg/L to 10 µg/L due to negative effects on the health. Therefore, the development of more effective arsenic removal methods has been required since then. In this study, the removal of arsenic from waters was carried out in an air lift batch mode electrocoagulation (EC) reactor where Fe balls were used as anode materials. Effects of independent variables besides anions and cations on removal of As(III) and As(V) from waters were investigated by Box-Behnken experimental design optimization. The relationship between responses and independent variables was expressed with quadratic model equations and high values of R2 (>0.85) and Adj-R2 (>0.80) from ANOVA analysis were obtained. Effects of especially current (i), EC time (tEC), air flow rate (Qhava) and column height in the reactor (h) on removal of As(III) and As(V) from waters were observed when Fe anode balls were used. As we considered to provide the required MCL on removals of As(V) and As(III) with Fe anode balls, values of lower tEC and i showed for better removal efficiency of As(V) with Fe anode balls. In addition, this process was also very effective for removal of As(III). Removal efficiency of arsenic was reduced with increasing concentrations of CSiO3-Si and CPO4-P while its removal efficiency is increased with increase in operating time. The rest of the anions show hardly noticable effect on the removal effciency of arsenic. In contrast the removal efficiency of arsenic significantly increased by increasing concentrations of CFe and CCa and its removal efficiency increased when operating time increased. As a conclusion, this study could be considered for removal of arsenic from waters as an alternative process.

Benzer Tezler

  1. Atherosklerotik kalp hastalıklarında risk faktörleri

    Risk factors in the coronary artery disease

    MURAT SUHER

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1987

    KardiyolojiGazi Üniversitesi

    İç Hastalıkları Ana Bilim Dalı

  2. Pasif güneş enerjisi sistemi ile bina ısıtılmasının ekonomik analizi

    Başlık çevirisi yok

    AHMET AKDENİZ

    Yüksek Lisans

    Türkçe

    Türkçe

    1987

    EnerjiEge Üniversitesi

    Enerji Ana Bilim Dalı

    DOÇ. DR. HULUSİ DEMİR

  3. Karıştırıcılar ve karıştırma kabındaki akım olaylarının incelenmesi

    Başlık çevirisi yok

    NADİR İLTEN

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    Makine MühendisliğiUludağ Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    DOÇ.DR. ÖMER SAMİH MERTBAŞ

  4. Kömürdeki piritin giderilmesi ve çözünürleştirme kinetiğinin incelenmesi

    Başlık çevirisi yok

    YAVUZ ONGANER

    Yüksek Lisans

    Türkçe

    Türkçe

    1987

    Kimya MühendisliğiAtatürk Üniversitesi

    DOÇ. DR. M. MUHTER KOCAKERİM

  5. Küçük Yamanlar tepesi örneğinde kent yakın çevresinde rekreasyon alanı düzenleme projesi

    Başlık çevirisi yok

    NİHAN BULGUN

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    Şehircilik ve Bölge PlanlamaEge Üniversitesi

    Peyzaj Mimarlığı Ana Bilim Dalı

    DOÇ. DR. İLÇİN ASLANBOĞA