Etkin doz ve görüntü kalitesinin hastaya spesifik olarak belirlenmesi ve diagnostik referans doz seviyeleri ile karşılaştırılması

Determination of effective dose and image quality patient specifically and comparison with diagnostic reference dose levels

  1. Tez No: 406420
  2. Yazar: BETÜL YAMAN
  3. Danışmanlar: YRD. DOÇ. DR. ÖZLEM BİRGÜL
  4. Tez Türü: Yüksek Lisans
  5. Konular: Fizik ve Fizik Mühendisliği, Radyoloji ve Nükleer Tıp, Physics and Physics Engineering, Radiology and Nuclear Medicine
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2015
  8. Dil: Türkçe
  9. Üniversite: Ankara Üniversitesi
  10. Enstitü: Nükleer Bilimler Enstitüsü
  11. Ana Bilim Dalı: Medikal Fizik Ana Bilim Dalı
  12. Bilim Dalı: Sağlık Fiziği Bilim Dalı
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Radyolojik incelemelerde, uygulamada genellikle standart hasta için önerilen ışınlama parametreleri kullanılarak görüntü alınmaktadır. Aynı inceleme için (karın, göğüs vb.) farklı kilo ve boylarda hastalar incelense bile aynı ışınlama parametreleri kullanılmakta, bu da çoğu zaman ya hasta radyasyon dozunda artışa ya da görüntü kalitesinde düşüşlere sebep olmaktadır. Klinik ortamda bu parametrelerin hasta dozuna ve görüntü kalitesine etkilerinin incelenmesi ve referans doz seviyelerinde sapma miktarlarının belirlenmesi gerekmektedir. Bu tez çalışmasında ilk olarak farklı klinik protokoller için düşük kontrast ayırma gücü fantomu ile alınan ham ve işlenmiş görüntüler kullanılarak görüntü kalitesi kontrast analizleri yapılmış, farklı firmaların kullandığı görüntü işleme yöntemleri kıyaslanmıştır. Hasta çalışmaları kapsamında ise üç farklı sistem için, farklı vücut kitle indeksine sahip hastalarda hasta yüzey dozu, etkin doz ve görüntü kalitesi sayısal olarak belirlenmiş; referans doz seviyeleri ile karşılaştırılmıştır. Hasta verilerinin değerlendirmesi aşamasında aynı çalışmalar hümanoid fantomla yapılmış hesaplanan kontrast değerleri hasta sonuçları ile kıyaslanmıştır. Hümanoid fantom ve hastalar için farklı yapılar arasında hesaplanan kontrast değerlerinin aynı davranışı gösterdiği görülmüştür. Hasta verileri radyolog hekimler tarafından EC 16260 EN'de bulunan kriterlere göre görsel olarak da değerlendirilmiş ve sistemler kendi içlerinde karşılaştırılmıştır. Sistemler arasında aynı vücut kitle endeksine sahip hastalarda yüzey dozu değişimi çok fazla olduğu görülmüştür. Doz ve görüntü kalitesi arasında sayısal olarak elde edilen sonuçlar ve radyolog hekimler tarafından yapılan görsel değerlendirmeler uyumludur

Özet (Çeviri)

In general, exposure parameters defined for standart patient are used to acquire images in radiological examinations in practice. For a specific examination (abdomen, thorax etc.), even if the physical properties (weight, height ec) of the patients are different, the same parameters are used and this results in either increased patient radiation dose or degraded image quality. It is necessary to study the effect of exposure parameters on patient dose and image quality in clinical setting and determine the deviation from reference dose levels. In this thesis, firstly contrast analysis in image quality was examined for different clinical protocols with raw and processed image data for a low contrast detail phantom acquired from different systems and image processing methods used in different brands were compared. For patient studies, patient surface dose and image quality were numerically calculated for patients with different body mass index using three different systems and results were compared with reference dose levels. For the evaluation of patient data, same data were acquired using humanoid phantoms and contrast values calculated were compared with the paitent results. The contrast between different tissues calculated from phantom and patient data presented similar behaviour. Patient data were also evaluated visually by radiologists according to criteria defined in EC 16260 and inter-system comparisons were made. The variation of patient surface dose among different systems was found to be very high even for patients with the same body mass index. The numerical results and evaluations of radiologists on the relation between dose and image quality were consistent

Benzer Tezler

  1. Bazı esterlerin kinetik incelenmesi ve termodinamik parametrelerin belirlenmesi

    Kinetic study and detesmination of thermodnamic parameters of some esters

    İBRAHİM TAŞ

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    Uludağ Üniversitesi

    Kimya Ana Bilim Dalı

    Yükleniyor...

  2. Posterior fossa tümörleri

    Başlık çevirisi yok

    SERHAT AYDINER

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1987

    Gazi Üniversitesi

    Nöroşirürji Ana Bilim Dalı

    Yükleniyor...

  3. Landsat uydusu aracılığı ile elde edilen görüntülerin sınıflandırılmaları ve bunlara ilişkin bilgisayar programlarının hazırlanması

    Başlık çevirisi yok

    G. FERZAN KÜÇÜKA

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    Ege Üniversitesi

    Bilgisayar Bilimleri ve Mühendisliği Ana Bilim Dalı

    Yükleniyor...

  4. Gelişim nörolojisi polikliniğine başvuran nöral tüp defektli olgularda prospektif bir inceleme

    Başlık çevirisi yok

    İLKBAHAR EMİNE GÜLTEKİN

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    İstanbul Üniversitesi

    Aile Sağlığı Ana Bilim Dalı

    Yükleniyor...

  5. Samsun ve çevresinde tarla sarmaşığı (conuolvulus arvensis L.)'na karşı biyolojik savaşa esas olacak fauna tespiti

    Investigations on the insect fauna of the field binweed (Conuolvulus arvensis L.) related to its biological control in Samsun Province

    YASEMİN UFUK GERMAN

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    Ege Üniversitesi

    Bitki Koruma Ana Bilim Dalı

    Yükleniyor...