Düşük seviye sıvı sintilasyon sayım (lsc) tekniği ile içme sularında toplam alfa ve beta aktivitesinin ölçülmesi için standart bir yöntem uygulanması

Application of a standard method for the measurement of gross alpha and beta activities in drinking water by using low level scintillation counting (LSC) technique

  1. Tez No: 406428
  2. Yazar: RUFİYET GÜVEN
  3. Danışmanlar: YRD. DOÇ. DR. GAYE ÖZGÜR ÇAKAL, PROF. DR. HALUK YÜCEL
  4. Tez Türü: Yüksek Lisans
  5. Konular: Fizik ve Fizik Mühendisliği, Physics and Physics Engineering
  6. Anahtar Kelimeler: İçme suyu, toplam alfa ve beta, LSC, orantılı sayaç, puls şekil analizi (PSA), düşük seviye aktivite, Drinking water, gross alpha and beta, LSC, proportional counter, pulse shape analysis (PSA), low level activity
  7. Yıl: 2015
  8. Dil: Türkçe
  9. Üniversite: Ankara Üniversitesi
  10. Enstitü: Nükleer Bilimler Enstitüsü
  11. Ana Bilim Dalı: Medikal Fizik Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

İnsanların maruz kalabileceği doğal radyasyon, karasal ve kozmik kaynaklardan ileri gelir. İçme sularının kaynağı yer altı sularıdır ve yer altı sularına kayaçlardan çözünerek geçen radyonüklitler sebebiyle sularda her zaman radyoaktivite bulunma riski vardır. İçme suları kaynaklı alfa ve beta iyonlaştırıcı radyasyonunun dokularda oluşturabileceği hasarı ve dolayısıyla, sağlık riskini asgaride tutmak gereklidir. Bu nedenle, Dünya Sağlık Örgütü (WHO) içme suları nedeniyle kişinin alabileceği dozu 0,1 mSv/yıl ile sınırlamıştır. İçme sularının radyasyon açısından izlenmesinde, Avrupa Birliği tarama seviyesini toplam alfa aktivitesi için 0,1 Bq/L ve toplam beta aktivitesi için 1 Bq/L olarak belirlemiştir. Bu değerler, Ulusal mevzuatımız gereği aynı şekilde uygulanmaktadır. İçme sularındaki toplam alfa ve beta yayınlayıcılar için izin verilen aktivite sınır değerlerinin altında kalan, düşük seviyedeki radyoaktivitenin hassas şekilde ölçülmesi çok önemlidir. Bu tez çalışmasının amacı, içme sularında radyoaktivite ölçümü için EPA 900 prosedürüne göre geleneksel yöntem orantılı sayaç (PC) ve ASTM D7283-06 prosedürüne göre düşük seviye radyoaktivite ölçebilen sıvı sintilasyon sayım (LSC) tekniklerini karşılaştırmaktır. İçme suyu örneklemesi en az 1 L olmak üzere, Ankara'nın farklı semtlerinden alınan 53 adet musluk suyu ile 38 adet ticari şişe suyu toplanarak yapılmıştır. Laboratuvarda numuneler, numune kabına radyonüklit adsorbsiyonunu önlemek amacıyla PH<2 olacak şekilde asitlendirilmiştir. Aynı numuneden belirli hacimlerde ayrılan özdeş numuneler, belirli işlemlere göre hazırlandıktan sonra, P-10 gaz akışlı orantılı sayaç (Canberra LB4110) ve düşük seviye LSC (Quantulus1220) ölçüm sistemleri kullanılarak analiz edilmiştir. Her iki teknikle de yapılan toplam alfa ve toplam beta analizleri sonucunda, Ankara ili musluk sularında ve şişe sularında, izin verilen aktivite sınır değerlerinin üzerinde bir radyoaktiviteye rastlanmamıştır. Rutin radyoaktivite taramalarında, düşük seviye LSC tekniğinin, numune hazırlama süreci daha basit, PMT'nin yüksek sintilasyon verimi nedeniyle daha kısa sayım süresinde yüksek sayım istatistiği vermesi sonucu kesinliği ve doğruluğu daha yüksek, tekrarlanabilir sonuçların elde edildiği ve daha güvenilir olduğu değerlendirilmiştir. Tezde elde edilen analiz bulgularına dayalı olarak bu iki yöntemin uyumu ve farklılıkları tartışılmıştır. 2015,79 sayfa

Özet (Çeviri)

The natural radiation exposure to human being is mainly arising from terrestrial and cosmic sources. The source of drinking water is under-groundwater and there is always a risk of radioactivity due to the presence of radionuclides coming from the rocky structures. It is essential that hazards to tissue, and hence the health risks due to alpha and beta ionizing radiation from radionuclides in drinking waters is kept at a minimum level. For this reason, World Health Organization (WHO) stipulated the radiation dose limit of 0.1 mSv/y for the individual, depending on drinking water consumption. For survey purposes, European Union (EU) was determined the allowed limits of drinking waters for gross alpha activities as 0.1 Bq/L and gross beta activities as 1 Bq/L. These limit values are also adopted in our National Regulations. Therefore, it is very important to measure accurately these very low level radioactivities occuring in drinking water samples. The aim of this thesis is to compare conventional proportional counter (PC) technique using EPA 900 method with low level Liquid Scintillation Counting (LSC) technique using ASTM D7283-06 standard. 53 tap water samples from different districts of Ankara and 38 commercial bottled waters each having at least 1 L were used in this study. The collected samples were then conditioned, by keeping in the laboratory as pH<2 to avoid the radionuclide adsorption on the walls of the container. Identical samples prepared from the same coded sample were prepared according to the procedures and analyzed by using gas flow (P-10) proportional counter (Canberra LB 4110) and low level LSC system (Quantulus 1220). The gross alpha and beta activity results in the Ankara tap water and bottled water samples obtained by using both of these techniques indicated that there is no observed the radioactivity values above the required limits. In routine radioactivity surveys, low level LSC technique can be considerd to be a more reliable method due to its relatively easy sample preparation and high scintillation efficiency of PMTs, thus resulting in high sentistivity. With use of LSC method, reproducible, more accurate and precise results can be obtained as a result of high count statistics acquired in a short time. In the thesis, the advantages and disadvantages of these two practical techniques based on our measurements in drinking water were compared and discussed. 2015,79 pages

Benzer Tezler

  1. Bilgisayarlı görü tabanlı fosforesans işaretleme yöntemiyle karanlık ortamlarda sıvı seviye ölçümü ve kontrolü

    Liquid level measurement and control in dark environments with computer vision-based phosphorescent marking method

    SEYİT AHMET İNAN

    Doktora

    Türkçe

    Türkçe

    2025

    Mekatronik MühendisliğiIsparta Uygulamalı Bilimler Üniversitesi

    Mekatronik Mühendisliği Ana Bilim Dalı

    DOÇ. DR. BEKİR AKSOY

  2. Grey prediction based control of a non-linear liquid level system using PID type fuzzy controller

    Non-lineer sıvı seviye sisteminin gri öngörüsel temelli PID tipi bulanık denetleyici ile denetimi

    ERDAL KAYACAN

    Yüksek Lisans

    İngilizce

    İngilizce

    2006

    Elektrik ve Elektronik MühendisliğiBoğaziçi Üniversitesi

    Sistem ve Kontrol Mühendisliği Ana Bilim Dalı

    PROF.DR. OKYAY KAYNAK

  3. A novel liquid level sensor design using laser optics technology

    Lazer optik teknolojisi ile yeni bir sıvı seviye sensörü

    MEHMET EMRE ERDEM

    Doktora

    İngilizce

    İngilizce

    2012

    Makine Mühendisliğiİstanbul Teknik Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    PROF. DR. DOĞAN GÜNEŞ

  4. Akıllı sıvı dağıtım ve kontrol sistemine sahip içecek buzdolabı tasarımı ve uygulaması

    The design and implementation of a beverage refrigerator with an intelligent liquid dispensing and control system

    YİĞİT ALOĞLU

    Yüksek Lisans

    Türkçe

    Türkçe

    2026

    Elektrik ve Elektronik MühendisliğiManisa Celal Bayar Üniversitesi

    Elektrik ve Elektronik Mühendisliği Ana Bilim Dalı

    PROF. DR. HAYATİ MAMUR

  5. Stres altında sertleşen sıvı emdirilmiş kompozitlerin balistik özelliklerinin incelenmesi

    Examination of the ballistic properties of STF impregnated composites

    MURAT BERKAY ZEKA

    Yüksek Lisans

    Türkçe

    Türkçe

    2021

    Savunma ve Savunma TeknolojileriMilli Savunma Üniversitesi

    Kbrn-P Savunma Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ AYHAN AYTAÇ