Geri Dön

Bilgisayarlı tomografi doz indeksi dozimetrik ölçümlerinin Monte Carlo simülasyonu ile karşılaştırılması

Comparison of measurements of computed tomography dose index (CTDI) with Monte Carlo simulation

  1. Tez No: 408508
  2. Yazar: RECEP KANDEMİR
  3. Danışmanlar: PROF. DR. EMEL ADA, YRD. DOÇ. DR. KADİR AKGÜNGÖR
  4. Tez Türü: Yüksek Lisans
  5. Konular: Fizik ve Fizik Mühendisliği, Radyoloji ve Nükleer Tıp, Physics and Physics Engineering, Radiology and Nuclear Medicine
  6. Anahtar Kelimeler: Bilgisayarlı Tomografi, GAMOS, Monte Carlo Simülasyonu, CTDI, Radyasyon Dozu, Monte Carlo benzetimi, Computed Tomography, GAMOS, Monte Carlo Simulation, CTDI, Radiation Dose
  7. Yıl: 2014
  8. Dil: Türkçe
  9. Üniversite: Dokuz Eylül Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Medikal Fizik Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

AMAÇ : Bu çalı¸smanın amacı, bilgisayarlı tomografi doz indeksi (CTDI) verilerinin Monte Carlo hesaplama tekniğiyle elde edilebilmesi ve deneysel sonuçlarla karşılaştırılmasıdır. GEREÇ ve YÖNTEM : Bu çalışma deney ve teorik olmak üzere ikiye ayrılmıştır. Deney kısmında katıhal dedektör ve film dozimetre kullanılarak absorbe radyasyon dozu ölçümleri yapılmıştır. CTDI ölçümleri dedektör ile vücut ve baş fantomu kullanılarak gerçekleştirilmiştir. Teorik kısımda ise bilgisayarlı tomografi cihazı modellenmiş ve radyasyon dozu hesaplamaları Monte Carlo yöntemi ile yapılmıştır. BULGULAR : Teorik hesaplamalar ve ölçümlerle elde edilen longitudinal ve lateral doz profilleri karşılaştırıldığında veriler uyumludur. Karşılaştırmalarda film dozimetrenin radyasyon duyarlılığının düşük olduğu tespit edildiği için dedektör ölçümleri temel alınmıştır. Hava kerma ölçüm sonuçları kullanılarak Monte Carlo hesaplamaları için dönüşüm katsayıları hesaplanmıştır. SONUÇLAR : Absorbe radyasyon dozu ölçüm ve hesaplama sonuçlarının kullanılan fantomun tipine, uygulanan enerjiye ve filtre yapısına bağlı olarak değiştiği görülmüştür. Kullanılan fantomların homojen malzemeden yapılması ve simetrik hacime sahip olması gerçek hasta dozunu tespit etmekte hatalar doğurabilir. Monte Carlo tekniği gerçek hasta dozunun hesaplanmasını sağlayabilir.

Özet (Çeviri)

PURPOSE : The purpose of this study is to obtain the computed tomography dose index (CTDI) values and compare it with the Monte Carlo calculation technique. MATERIAL AND METHOD : This study consists of two parts, measurement and theory. In the experiment section, the absorbed radiation dose measurements obtained with the solid state detector and film dosimeter. The measurements of CTDI were performed in the body and head phantoms. In the theory section, the machinery of computed tomography is simulated and the calculations of radiation dose are done with the Monte Carlo technique. RESULTS : When the longitudinal and lateral profiles of the theoretical calculations and measurements were compared the results found to be consistent. In the comparisons, the measurements of detector is considered more reliable since the film dosimeter system has no high radiation sensitivity than the solid state. The conversion factors obtained from the measurements of air kerma results were calculated to be used in the Monte Carlo calculations. CONCLUSIONS : It is found that the results of measurement and calculation depend on the type of phantom, the energy of the radiation and the filter type. Since the phantoms are made of homogeneous material and in symmetrical structure,it could cause the errors in the real patient dose. The Monte Carlo technique gives us the ability to calculate the real patient dose.

Benzer Tezler

  1. Diesel motorları yakıt püskürtme sistemlerinin dinamik simülasyonu

    Başlık çevirisi yok

    İRFAN KARAGÖZ

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    Uludağ Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    Yükleniyor...

  2. Ağızlık açma mekanizmalarının tasarımı

    Başlık çevirisi yok

    RECEP EREN

    Yüksek Lisans

    Türkçe

    Türkçe

    1987

    Uludağ Üniversitesi

    Tekstil Mühendisliği Ana Bilim Dalı

    Yükleniyor...

  3. Doğuştan kalça çıkıklı hastalarda kalça patolojilerinin bilgisayarlı tomografi ile değerlendirilmesi

    Başlık çevirisi yok

    NECDET ŞÜKRÜ ALTUN

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1987

    Gazi Üniversitesi

    Ortopedi ve Travmatoloji Ana Bilim Dalı

    Yükleniyor...

  4. Kuyruk modelleri ve analizi üzerine bir uygulama

    Başlık çevirisi yok

    DİDEM ÖZPULAT

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    Ege Üniversitesi

    Bilgisayar Bilimleri ve Mühendisliği Ana Bilim Dalı

    Yükleniyor...

  5. Landsat uydusu aracılığı ile elde edilen görüntülerin sınıflandırılmaları ve bunlara ilişkin bilgisayar programlarının hazırlanması

    Başlık çevirisi yok

    G. FERZAN KÜÇÜKA

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    Ege Üniversitesi

    Bilgisayar Bilimleri ve Mühendisliği Ana Bilim Dalı

    Yükleniyor...

  6. Optimum gübre dağıtımı

    Başlık çevirisi yok

    MEHMET KAMİL AKYÜZ

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    Gazi Üniversitesi

    Yükleniyor...