Geri Dön

Medtronics endurant endovasküler stent greft kullanılarak abdominal aort anevrizması onarımı yapılan hastalarda cihaza ait IFU kriterleri ölçütünde tedavi etkinliğinin değerlendirilmesi

Evaluating the treatment efficiency in endovascular aneurysmal repair (EVAR), does IFU criteria, iliac fixation lenght and certain anatomic differences affect the endoleak rates, aneurymal sac enlargement and reintervention rates

  1. Tez No: 424568
  2. Yazar: NECATİ BATURALP GÜNER
  3. Danışmanlar: DOÇ. DR. AYTAÇ GÜLCÜ
  4. Tez Türü: Tıpta Uzmanlık
  5. Konular: Radyoloji ve Nükleer Tıp, Radiology and Nuclear Medicine
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2016
  8. Dil: Türkçe
  9. Üniversite: Dokuz Eylül Üniversitesi
  10. Enstitü: Tıp Fakültesi
  11. Ana Bilim Dalı: Radyoloji Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: 76

Özet

Amaç ve Hipotez: Endovasküler anevrizmal onarım (EVAR) günümüzde Abdominal aort anevrizması (AAA) tedavisinde en sık tercih edilen yaklaşımdır. EVAR işleminde kullanılan stent greftlerin lisanslama aşamasında uygun oldukları anatomik sınırların belirlendiği, ingilizce indications for use (IFU) olarak adlandırılan kriterler mevcuttur. Ancak günümüzde pratik uygulamada bu kriterlerin dışında anatomiye sahip olmakla birlikte endovasküler stent greft onarımı yapılan büyük bir hasta grubu mevcuttur. EVAR uygulanan hastalarının IFU kriterleri dışında veya diğer zorlayıcı anatomik durumlarda tedavi etkinliğinin değerlendirildiği pek çok çalışma mevcuttur. Çalışmamızda Medtronics Endurant endovasküler stent greft kullanılarak tedavi edilmiş hastalar cihaza ait IFU kriterlerine uygunluklarına göre, ve seçilmiş anatomik kriterlere dayanarak gruplandırılmış ve hastaların tedavi etkinlikleri değerlendirilmiştir. Yöntem: 2009-2015 yılları arasında Endurant stent greftle EVAR işlemi yapılan hastalar içerisinde hastane veritabanında takip radyolojik görüntüleri bulunan hastalar çalışmaya dahil edilmiştir (50 hasta). Hastalar IFU kriterlerine göre (IFU dışı ve IFU içi hastalar olarak) gruplandırılmıştır, IFU kriterleri dışında IFU kriterlerini oluşturan 1-aortik boyun uzunluğu, 2-zor boyun anatomisi (hostile neck anatomy), 3-IFU dışı iliak anatomi (>25mm), 4-İliak fiksasyon uzunluğu (20mm) 6-Anevrizmal kese çapı (>7cm), 7- Aortik boyunda trombüs ve kalsifikasyon görülme oranına göre gruplandırmalar yapılmış ve bu gruplar arasında tedavi etkinliği değerlendirilmiştir. Tedavi etkinliğini değerlendirmek amacıyla hastaların 1-Primer operasyonda kullanılan parça sayısı 2-Takiplerinde tip 1-3 endoleak görülme oranı, 3-Takip görüntülemede 5mm'nin üzerinde anevrizmal çap artış görülme oranı, 4-Takip görüntülemede 2mm'nin üzerinde iliak çap artış görülme oranı, 5-Takipler sırasında ek girişim ihtiyacı not edilerek gruplar arası istatistiksel farklılıklar gözlenmiştir. Bulgular: Takip grubundaki hastaların %48'i (24 hasta) IFU içi, %52'si (26 hasta) IFU dışı anatomiye sahipti. IFU dışı grupta primer operasyon sırasında kullanılan stent greft parça sayısı istatistiksel anlamlı olarak fazla görüldü (p=0,02). Tip 1-3 endoleak geliştirme, aortik çap artışı görülme ve ek girişim ihtiyacı görülme oranlarında istatistiksel anlamlı farklılık saptanmadı (p değerleri sırasıyla 0,351; 0,669; 1). Oluşturulan diğer anatomik kriterler değerlendirildiğinde IFU kriterlerine göre zor aortik boyuna (hostile neck), proksimal aortik boyunda trombüs bulunan, kısa proksimal fiksasyon uzunluğuna (

Özet (Çeviri)

Objective: Evaluating the differences in endoleak rates, aneurysmal sac \ iliac expansion rates, reintervention rates and number of endograft modules used in EVAR patients with different anatomical features, including IFU criteria, iliac fixation and aneurysmal sac diameter. Methods: Fifty patients which are treated with Medtronics Endurant endovascular stent graft in years 2009-2015 in Dokuz Eylul University Interventional Radiology department were included in our study. The patients were grouped according to their IFU criteria compliance, each IFU criteria on a separate evaluation and several other anatomical features including: 1-Iliac fixation lenght, 2-Aneurymal sac diameter exceeding 7cm treshold 3-İliac diameter exceeding 20mm 4-existence of proximal aortic mural thrombus/calcification. The treatment efficiency of different groups are evaluated using criterias: 1-Type 1-3 endoleaks in follow-up 2-Aneurysmal sac and iliac expansion rates 3-Reintervention rates 4-The number of stent graft modules needed in primary operation. The statistical differences among groups were evaluated. Findings: Forty eight percent of patients (24 patients) in follow up group were compliant with IFU criteria and 52% of patients (26 patients) had outside IFU anatomy. The patients who does not match IFU criteria, statistically higher number of endograft modules were used (2,38 versus 2,52 p=0,023). The rates of type 1-3 endoleaks, aortic sac expansion end reintervention rates were same amoung IFU compliant and outside IFU groups (P values 0,351; 0,669 and 1 respectively). In patient groups with hostile neck anatomy, short proximal aortic fixation lenght (>10mm) and outside-IFU iliac anatomy (>25mm), the rates of type 1-3 endoleaks, reintervention rates and aneurysmal sac expansion rates were not statistically different. In patients with inadequate iliac fixation (

Benzer Tezler

  1. Medtronic-hall kalp kapak protezlerinin klinik değerlendirilmesi (retrospektif klinik çalışma)

    Başlık çevirisi yok

    ATİLLA ARAL

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1993

    Göğüs Kalp ve Damar CerrahisiAnkara Üniversitesi

    Kalp ve Damar Cerrahisi Ana Bilim Dalı

  2. Tıbbi cihaz sektöründe bütünleşik pazarlama iletişimi çabaları; Medtronic Medikal firması örneği

    Integrated marketing communication efforts in medical device industry; Example of Medtronic Medical technology company

    YAŞAR MEHMET BAYKAL

    Yüksek Lisans

    Türkçe

    Türkçe

    2017

    İşletmeAdnan Menderes Üniversitesi

    İşletme Ana Bilim Dalı

    YRD. DOÇ. DR. MUSTAFA DOĞANER

  3. Enerji tabanlı cihazların bağlamasız tiroidektomi sonrası yaşam kalitesi üzerine etkisinin karşılaştırılması

    Comparison of effects of energy based devices on quality of life after sutureless thyroidectomy

    AKİF ENES ARIKAN

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2016

    Genel Cerrahiİstanbul Üniversitesi

    Genel Cerrahi Ana Bilim Dalı

    PROF. DR. MUSTAFA ATEŞ ÖZYEĞİN

  4. Tek elektrotla atriyal senkronizasyonlu ventriküler pacing sisteminin (VDD) klinik değerlendirilmesi

    CLinical evaluation of single-lead atrial syncronous ventricular pacing (VDD) system

    FATİH SİNAN ERTAŞ

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1997

    KardiyolojiAnkara Üniversitesi

    Kardiyoloji Ana Bilim Dalı

    PROF. DR. REMZİ KARAOĞUZ